D. May, D/ODP
Attached is the User
2.
Requirements for an Agency
Standard Soft Co Computer
Terminal. A draft copy of
3,
this document was reviewed in
September by the entire Term-
inal Requirements Working
4.
Group. In October the ODP
contingent of the group (Bill
5.
reviewed the
6.
comments rom the entire
group. I've scheduled distri
bution of tIris resulting
7,
updated document to the
entire group on 7 November
1977.
B,
As chartered, an RFP is
now being prepared by Engi-
neering Division with my par-
9,
ticipation. Much of Section
II and III of the requirements
document is appropriate for
10,
direct inclusion into the RFP.
dditional refinement, from
an engineering rather than a
11.
user requirement standpoint,
must be done to the security/
emanations and communications
12.
portions of this document by
ngineering Division during
the RFP generation period.
13.
If you have any comments
lease call.
?
c
c d C/ihS
14.
i~r.~i a O~( r
15
.
PREVI
INTERNAL
1' 610 U EDITIONSUS ^ SECRET ^ CONFIDENTIAL ^ SF ONLY ^ UNCLASSIFIED
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
USER REQUIREMENTS FOR AN
AGENCY STANDARD SOFT COPY
COMPUTER TERMINAL
it
?
010101?110" '1101 00001111n.-
011001 illooll 11 1101100 110001
101? 10000: 001110 0011
110 .,UIIU, 111(c 1 1010 110
00, 1100100101 101 J10111112L 10011 L,0,i;lL 1 11
00 ~0110010011 I )11( .100001 1010 )11001 111
11 001101000011 , 101 10001011 )100 101
10 U100200011. , ill LOOOOOO, 3100 lill
01 0, in JIM )201 10121 --V001000111
1100, 1001 11 0 .000001 .001111006000 11
000,11, '01101 101 10100011 11000100001001
0010010011- -111111010001 ------ -.111100111010 ~11101010011111
26 October 1977
Office of Data Processing
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
USER REQUIREMENTS
FOR AN
AGENCY STANDARD SOFT COPY COMPUTER TERMINAL
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
PAGE
I.
Introduction .................................
1
II.
General Terminal Requirements ................
2
A.
Configuration ............................
2
B.
Display Functions and Character Sets .....
3
C.
Terminal Controls and User Entry
Devices ................................
5
D.
Transmission Parameters ..................
6
E.
Emanations Control .......................
7
III.
Key
Requirements .............................
8
A.
Terminal Emulation and Mainframe
Accessibility ..........................
8
IV.
Terminal Technology Considered ...............
10
A.
Vendor Presentations .....................
10
B.
CRT vs Non-CRT Soft Copy Displays ........
10
C.
Some Conclusions .........................
10
V.
Glossary of Terms ............................
11
Attachment I
--
Terminal Questionnaire
Attachment II
--
Terminal Questionnaire Responses
Attachment III
--
Project SAFE Workstation (Terminal)
Requirements (Excerpt from: SAFE
Functional Requirements -- Dated
1 March 1977)
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
This document contains the user requirements
for a soft copy* computer terminal which will be
adopted as Agency standard for the period FY 78 to
FY 83. It was prepared by the ODP contingent of
the Terminal Requirements Working Group. The
Terminal Requirements Working Group, chartered
in April 1977, consisted of representatives from
most components of the Agency.
A primary input to this document was the
Terminal Questionnaire (Attachment I) that was
completed by members of the entire Working Group
during June-September 1977. Also considered was
the availability of terminal features in the
marketplace. This information was obtained from
the literature, discussions with users, and through
vendor presentations to the Terminal Requirements
Working Group.
A draft version of this document was distributed
for comments to the entire Working Group during
September 1977. Resulting comments were reviewed
by the ODP contingent of the Working Group.
An important assumption for the requirements is
that existing Agency Delta Data and some of the
other Agency terminals will remain in use until at
least FY 82. That is, existing terminals will
continue to service a large portion of the Agency's
terminal requirements for several years.
The requirements specified in this document
shall be used as input to a Request for Proposal
(RFP) to be generated by Engineering Division of
ODP for competitive procurement of terminals.
Much of the Section II and II of this document is
appropriate for direct inclusion into an RFP.
Additional refinement, from an engineering rather
than a user requirement standpoint, must be done
to the security/emanation and communication
portions of this document by Engineering Division
during the RFP generation period.
* As opposed to hard copy.
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
uH 4" J3irILL)
The user requirements for general terminal features
are based upon availability in the market place and the
terminal questionnaire ratings (See Attachment II) and
comments. Questionnaire items, when applicable, are
referenced following the feature.
A. Configuration
1. Local Peripheral Support
a. Mandatory
? The ability to interconnect to a local*
low to medium quality printer* and to a
local* high quality printer* (.II.A.10 and
II.A.11).
? The ability to overlap local* printing
with normal operation of the terminal
(.II.A.12).
The ability to add a local* removable data
storage (e.g., cassette tape drive(s) or
diskette drive(s)) capability of at least
90K bytes on-line (II.A.8).
? The ability to add a local*, removable data
storage capability of at least 1 million
bytes on-line (II.A.8).
2. Local Capability/Compatibility
a. Mandatory
? Local character editing* (II.A.4 and II.A.5).
? Validation of the data locally*, prior to
transmission to the mainframe(s) (II.A.6).
The ability to acid a capability for local
text editing* (II.A.4).
? Compatible with the Agency's general office
environment.
* See Glossary
-2-
II PIIt
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
i~.S.~.,s, i~.! AL'
a. Mandatory
? Not a floor model.
? No larger than a Delta Data 5000 series
terminal*.
4. Programmability
a. Mandatory
? Terminal is supported by firmware architec-
ture which is customer modifiable.
? Ability for firmware image to be changed
from host computer.
? Ability for users to program on terminal,
locally (e.g., using BASIC on terminal,
independent of host computer).
0 The ability for the terminal to be used at
domestic remote locations (outside the
Washington, D.C. area) and overseas sites,
subject to local power supply and security
requirements (II.A.2 and II.A.3).
B. Display Features and Character Sets
1. Display Area and Format
a. Mandatory
0 24 lines in an 80 column screen format (II.B.4).
0 Usable display area** of at least 45 square
inches (II.B.10).
* A requirement for a terminal with size smaller than
the Delta Data 5000 series terminals eliminates
vendors who otherwise may be able to accommodate
mandatory requirements.
** See Glossary
-3-
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
At least 27 lines in an 80 column screen
format (II.B.4)*.
? Usable display area*** of at least 90
square inches (II.B.10).
? At least 4000 characters per screen full***.
2. Other Display Features
a. Mandatory
? Glare-free screen.
? Screen that is free of perceptible flicker.
? Adjustable over-all screen intensity using
a control(s) that is easily operator
accessible (II.B.8).
? Nondestructive cursor which is easily
locatable by the user.
? Addressable/readable cursor.
The ability to retain at least 16
tabulation*** positions (II.B.14).
? Backtabbing (II.B.13).
? Buffering to allow storage of 3 full screens
of char ter data and a paging*** function
to disp1 this data (II.A.15).
? Scrolling (Rolling)***.
? At least three modes of selective high-
lighting. Examples of highlighting are:
reverse video***, blinking, underlining
* A requirement for 27 display lines on the terminal
screen (as in ODP's Delta Data) reduces the number
of potential vendors to one or two. The most common
number of display lines is 24.
** A requirement of 132 characters per display line
eliminates virtually all potential vendors.
*** See Glossary.
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
and two brightness levels (II.B.2 and
II.B.8 and II.B.9).
? Split display screen* (II.B.1).
? Format, system available and insert
mode indicators.
b. Desirable
Multi-color display capability (II.B.3).
? The ability to make bar charts and simple
line graphs (II.A.7).
? Buffering to allow storage of more than
three screens full* of character data and
a paging* function to display this data
(II.A.15).
? At least four programmable status indi-
cators.
3. Character Sets
a. Mandatory
? At a minimum the full ASCII upper and lower
case 96 character set (II.B.5).
? Ability to support an APL character set and
a two character overstrike feature on
terminal (II.B.6).
b. Desirable
? User programmable character set.
? Ability to accommodate additional character
sets (e.g., foreign language character sets).
C. Terminal Controls and User Entry Devices
1. Light Pen
a. Mandatory
? The ability to attach a light pen (used for
field selection and attention getting) to
selected terminals (II.C.l).
* See Glossary.
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
2. Keyboard
a. Mandatory
? N-key roll over*.
? At least 12 programmable function keys
(II.C.5).
? A switch within easy user reach that
converts the terminal from upper/lower
case to upper case only and vice versa
(II.C.3).
? The ability to easily repeat characters
(II.C.4).
? Detachable keyboard (II.C.2).
? Different pressures for selected keyboard
keys.
0 Numeric keypad with decimal point.
? Acoustic feedback from keyboard.
3. Terminal Controls and Alarms
a. Mandatory
? Programmable audible alarm.
? ON/OFF switch.
0 The ability to add a physical lock
mechanism on terminal (II.C.6)
D. Transmission Parameters
1. Transmission Speed
a. Mandatory
? Transmission speed switch selectable up
to and including 4,800 baud (II.D.1).
* See Glossary.
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Transmission speed switch selectable up
to and including 9600 baud (II.D.1).
2. Transmission Technique
a. Mandatory
? A terminal configuration supporting the
synchronous transmission technique.
o A terminal configuration supporting the
asynchronous transmission technique.
A configuration supporting both the
synchronous and asynchronous transmission
technique on the same terminal.
a. Mandatory
? At least longitudinal redundancy checking
and character parity checking at each
terminal.
E. Emanations Control
1. TEMPEST Testing
a. Mandatory
A version of the terminal is required such
that the display, associated user data entry
devices and connecting cables comply with
the Compromising Emanations Laboratory Test
Standard Electromagnetics, NACSEM 5100,
National Security Agency. Specific TEMPEST
test requirements will be stated in request
for proposal (RFP) that will be used in
procurement of these terminals.
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
A. Terminal Emulation and Mainframe Accessibility
1. Emulation*. It shall be the intent of the
RFP to provide terminals sufficiently
compatible with the existing environments
such that they may be used in place of
existing terminals with minimal impact on
the user.
a. Mandatory
? The ability to implement emulation*
of most** of the features the Delta
Data 5260 (ODP configuration).
? The ability to implement emulation*
of most** of the features of Delta
Data 5000 (NPIC configuration).
? The ability to implement emulation*
of most** of the features of the
IBM 3270.
? The ability to implement standard
TTY protocol*.
? The ability to implement emulation*
of most** of the features of the
Beehive Superbee.
2. Mainframe Accessibility
a. Mandatory
? The ability to access one, two, or
more of the following mainframes
from individual selected terminals
(accessing more than one mainframe
is contingent upon a review of
security and communications
considerations):
* See Glossary.
** For example, a feature which may not practically be
emulated is: 27 lines in an 80 column screen format,
as on the Delta Data 5260.
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
? The ODP mainframes.
? The NPIC mainframe.
? The DDO mainframe.
? The COMIREX Automated Management
System (CAMS) mainframe.
The CAMS terminal requirements
will be finalized in the future.
Preliminary requirements are
addressed either as mandatories
or desirables in this document.
The SAFE terminal requirements
will be finalized in the future.
In the context of this document,
the requirements stated in
Section VII of the 1 March 1977,
SAFE Functional Requirements
(See Attachment III) shall be
treated as desirables. Where
conflicting requirements exist,
this document, not the SAFE
Functional Requirements, shall
supercede.
Terminals shall be attachable to
other mainframes. Communications
shall be in TTY mode*. Examples
are terminals attached to the
COINS and DIAOLS systems. Not
included is the interface of the
Electronic Text Editing and
Composing (ETEC) system with
ODP mainframe which is currently
under study by ODP.
* See Glossary.
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27 : CIA-RDP95-00972R000100170013-9
A. Vendor Presentations
Thirty four terminal vendors were invited to
provide information/presentations on their soft
copy terminal lines. This includes plasma panel
as well as CRT terminals. Twenty three vendors
responded and twenty gave presentations to the
Terminal Requirements Working Group on their
terminal line's features.
B. CRT vs Non-CRT Soft Copy Displays
Even though non-CRT soft copy displays,
including plasma panels, LED's and liquid crystal
displays, are gaining in popularity, CRT displays
dominate the alphanumeric display industry, and
are expected to do so for several years. Because
of the prohibitive cost of displaying large
quantities of data (e.g., 2000 characters) on non-
CRT displays, such devices are still a long way
from replacing the CRT.
C. Some Conclusions
CRT terminals or terminal lines do exist which
can be configured with relatively little development
to satisfy at least the responses of the mandatory
items in Sections II and III of this document. This
document does not presume that a single terminal
best satisfies all of the requirements in this
document. For example, two or more terminals within
a vendor's terminal line may best satisfy the
requirements.
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27 : CIA-RDP95-00972R000100170013-9
Addressable Readable Cursor - A cursor which the
computer can locate and move.
Emulation - The imitation of the features of one
terminal by another, perhaps considerably different,
terminal.
High Quality Printer - A printer with the approxi-
mate print quality of a standard electric office
typewriter.
Local - Independent of mainframe(s).
Local Character Editing - Manipulation of
characters by means of functions such as character
insert and character delete.
Local Text Editing - Manipulation of words,
sentences and paragraphs.
Low to Medium Quality Printer - A printer with
the approximate print quality of a 10 line per
minute nonimpact printer.
N-Key Roll Over - The sending of keyboard key
signals in the order that the keys were depressed
rather than in the order that they were released.
Paging - The storage of two or more pages,
screens full of data, and a function to shift
through and display this data.
Reverse Video - Negative image of character
or data (e.g., white or black instead of black on
white or vice versa).
Screen Full - A character in every position
of the usable screen area.
Scrolling (Rolling) - Moving all displayed
lines of data up or down by one line as a new line
is added and an existing one removed.
Split Display Screen - Splitting the display
screen into two or more parts with all of the
capabilities that apply to the screen in non-split
mode applying to each of the parts separately.
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
TTY Protocol - Transmission of ten bit ASCII
communications code using one start and one stop
bit.
Tabulation - The capability to set tab stops
differently for each line of the display.
Usable Screen Area - The part of the display
screen on which character data may be displayed.
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Name
Component
Extension
I.A. What CRT terminals does your component now
use?
Please separate Terminal Types according to
services (e.g., APL, ATS, BASIC, BATCHMON/ASP,
CAMEXEC, CAMS, CDS, COINS, DIAOLS, EDIT/SEDIT,
ETEC, GIMS, NDS, NIPS, RAMIS, SAFE (INTERIM),
STAR, SCRIPT, UMLS). To assist you, we have
included a list of your component's terminals
which (according to our records) are attached
to ODP hardware. Please correct any error or
deficiencies in this list.
Be sure to list below all CRT terminals,
not just those attached to ODP hardware.
Terminal Number of
Types Terminals Services
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
B. Which features, if any, of the above terminals
do you find inadequate?
C. Assuming that existing CRT terminals such as
the Delta Data, Superbee and IBM 3270 will remain
in use through at least FY 82; please provide a
"working" number (if any) of additional alpha-
numeric soft copy terminals that your component
will require in each of FY 78, FY 79, FY 80, FY
81, FY 82 and FY 83.
-2-
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
II. In the left-most column please rate each
item:
-1 Not required.
0 Not rated (_Uti.lity for my component's
applications is unknown).
1 Desirable (Evaluation based on cost).
2 Mandatory requirement.
In the second column for any item rated 1 or
2 please provide an estimated percentage of the
terminals indicated in Section I. C. which your
component requires (or desires) to have this
feature.
Also for item(s) rated 1 or 2, please describe,
when possible, your application(s) of the item(s).
You may use the space below item(s) or a separate
sheet of paper.
Some items which are obvious requirements
(e.g., non-glare terminal screen) have been
omitted.
Any items that you feel should be added may
be listed (and rated) at the end of any of the
sections (A, B, C or D) below.
A. Configuration
Rating Percentage
The ability to switch
terminals between
services (Refer to
Section I. A.) If
rating is 1 or 2,
associate services with
application (s) .
J,U` L', ELL
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
B vl Si r'~ G J 14 IY't` 'i2/08 d
Declassified in Part - Sanitized Copy Approved for Release 20/27: CIA-RDP95-009728000100170013-9
UMULNIUVII
Rating Percentage
The ability to be used at
domestic remote sites. If
rated 1 or 2, indicate
whether terminal size and
environment are consider-
ations?
The ability to be used at
overseas sites. If rated
1 or 2, indicate whether
size and environment are
considerations?
Word processing (e.g.,
SCRIPT, ATS).
Local text editing.
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
s~ '.a 9s+ 3 3zslsi+
Rating Percentage
The ability to make bar
charts and simple line
graphs.
Local (e.g., cassette,
floppy disk) storage
capability. If rated
1 or 2, please indicate
the amount of storage
you require (desire).
bytes.
Small size at the expense
of other features.
Interconnect to and support
a high quality printer.
Interconnect to and support
a low to medium quality
non-impact printer.
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Releas''e~ 2012_ /08/27: CIA-RDP95-00972R000100170013-9
I?A
Rating Percentage
The ability to overlap local
printing with normal operation
of terminal.
The ability to backtab ---
move the cursor to a previous
tab or format field.
The ability to retain
tabulation position(s).
If rated 1 or 2,
tabulation position(s)
are required (desired).
Buffering to allow storage
of at least one completely
full screen of character
data and a paging function
to display this data. If
rated 1 or 2, please
indicate, here, the number
of full screens of
character data you require
(desire).
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
B. Screen, Display Formats and Character Sets
Rating Percentage
Split display --- the
division of the screen
into two or more areas.
The ability to display
reversed video --- light
characters on dark back-
ground.
Multi-color display
capability.
The ability to display
at least 12 lines in an
80 column format. If
rated 1 or 2, please
indicate number of
lines
(either 12, 24, 27
or
more than 27) you
require
(desire).
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Rating Percentage
Full ASCII upper and lower
case character set (i.e.,
not ASCII upper case only)
Special character set(s)
(e.g., foreign language
character set(s)).
Variable intensity
character display.
Blinking
1 1.
I I NTo I A .31"Ri" IF bF T;-" &"]
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
LA L 1 I ILD
Rating Percentage
A display area of at
least 6 inches by 9
inches. If rated 1 or
2, please indicate
display area dimensions
(e.g., Delta Data 5260
has dimensions of 6
inches by 11 inches and
the IBM 3270 has a 14
inch diagonal dimension)
required (desired).
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08_/27: CIA-RDP95-00972R000100170013-9
ILL
C. Keyboard, Other Terminal User Entry Devices,
and Terminal Controls
Rating Percentage
Light pen.
Detachable keyboard.
A switch within easy
user reach that converts
the terminal from upper/
lower case (assuming of
course that the terminal
has both) to upper case
only and vice versa.
The ability to easily
repeat characters.
Programmable function
keys. If rated 1 or 2,
keys are
required (or desired)
F
K
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
UNUMSIMU
Rating Percentage
Physical key lock mechanism
at terminal.
UNCIASSIFB~
Decla ssified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27 : CIA-RDP95-00972R000100170013-9
r :4..
D. Display Speed
Rating Percentage
The ability to get full
screen display in less
than 15 seconds. If
rated 1 or 2, please
indicate number of
seconds (either 10 to
15 seconds, 6 to 10
seconds, 3 to 5 seconds,
1 to 2 seconds or less
than one second) required
(desired).
The Delta Data 5260 (ODP
version) requires, for
example, 6 to 10 seconds
to get full screen display
at a 2400 baud transmission
rate.
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
A
B
C
D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5 6
1
DDO
(ALL)
DDS&T
O/DDS&T
2
-1
-1
1
1
1
2
1
-1
2
2
1
2
2
1
1
1
1
2
2
-1
1
1
1
2
1
-1
2
2
2 1
1
FBIS
2
1
0
2
2
1
0
0
0
1
1
1
0
1
1
1
0
-1
1
2
0
2
1
-1
1
1
0
2
-1
1 2
1
NPIC
2
2
-1
1
2
2
1
2
-1
1
2
2
2
2
2
2
2
1
2
2
2
1
2
2
2
2
2
2
2
2 1
2
OD&E
2
0
-1
-1
-1
-1
1
-1
-1
1
2
-1
-1
2
2
-1
1
-1
2
-1
1
-1
2
0
2
1
-1
2
-1
- -1
1
OSO
2
0
0
1
1
1
1
0
-1
1
1
1
1
1
1
0
0
1
2
1
1
0
1
1
1
1
0
1
0
1 0
1
ORD
2
1
0
2
1
1
2
2
1
2
2
2
2
1
2
0
1
1
2
2
1
1
1
1
2
1
0
1
2
1 0
1
OTS
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- -
-
CIA OPS
CTR
1
-1
-1
-1
1
-1
0
0
0
2
-1
-1
-1
-1
2
2
0
0
1
0
0
0
0
0
0
0
0
0
0
0 0
2
OIA
2
2
-1
0
2
2
2
1
-1
2
2
1
2
0
1
0
-1
-1
2
2
-1
-1
2
2
0
1
-1
2
2
0 -1
2
OCR
2
-1
0
2
2
1
0
1
-1
2
2
1
2
2
2
2
0
0
2
2
0
2
2
1
2
1
1
2
2
2 1
2
OER
2
-1
-1
0
0
0
1
0
-1
2
0
0
0
0
2
-1
-1
0
2
1
2
-1
-1
-1
2
-1
-1
1
1
- -1
2
OGCR
2
-1
-1
1
1
1
1
1
-1
2
1
1
1
2
2
1
0
1
2
2
0
1
0
1
2
1
1
2
0
0 0
1
ORPA
2
0
0
1
2
2
1
1
0
1
1
1
1
0
2
1
1
1
2
2
1
1
1
1
2
1
1
2
0
1 0
2
OSI
2
0
-1
2
2
2
1
2
-1
2
2
2
1
1
2
1
1
1
2
2
2
2
2
2
2
1
-1
2
2
2 -1
2
OSR
1
1
-1
2
2
1
2
0
-1
2
2
2
1
2
2
1
-1
1
2
2
2
1
2
1
2
1
0
2
2
1 0
1
OWI
2
-1
-1
2
2
2
2
1
-1
1
2
1
2
2
1
1
0
0
2
2
1
0
2
2
2
2
0
1
1
1 -1
0
COMIREX
2
2
1
1
1
1
1
1
-1
2
1
1
1
1
1
2
0
1
0
2
1
-1
0
0
0
0
0
0
0
2 2
2
OGC
0
-1
-1
0
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
1
-1
-1
-1
0
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
0 -1
0
IC STAFF
1
2
-1
1
0
0
-
0
0
1
2
1
1
1
2
0
0
0
1
1
1
0
0
0
1
0
0
0
0
0 0
1
IG STAFF
2
-1
-1
0
0
-1
0
-1
-1
-1
2
0
2
-1
2
-1
-1
-1
2
-1
0
-1
-1
-1
0
-1
-1
2
-1
-1 -1
-1
RES
1
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
1
0
0
0
0
0
1
0
0
0
0
0 0
1
O/COMPTROLLER
2
0
0
0
1
0
1
0
0
1
2
0
0
0
2
0
0
0
1
0
0
0
1
0
0
0
0
0
0
0 0
1
P
NIC, ,
J
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
EQ~rs s
A B C D
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 1
OF -1 0 0 -1 2 2 2 -1 0 2 2 0 2 0 2 0 -1 -1 2 1 0 -1 2 2 2 -1 -1 2 2 0 -1 2
OL 2 2 0 2 2 1 1 1 -1 2 2 1 2 2 2 -1 1 -1 2 2 0 -1 1 -1 2 0 1 1 2 2 1 2
OMS 2 2 1 0 2 2 -1 1 0 0 1 0 1 1 1 -1 -1 -1 1 0 0 -1 2 -1 1 1 -1 0 -1 1 -1 0
OP 2 -1 -1 0 2 2 1 2 1 1 2 1 2 2 2 0 -1 -1 1 2 -1 -1 2 2 2 -1 -1 1 1 0 -1 2
Os 2 2 0 2 2 2 1 0 0 2 2 1 2 2 2 1 0 1 2 2 1 -1 2 2 2 1 -1 2 2 1 2 2
OTR 2 1 1 1 1 0 1 0 -1 2 2 1 0 2 2 0 0 1 2 1 1 0 0 1 2 1 0 2 0 0 0 2
ISAS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
OC 2 2 -1 2 2 2 2 -1 -1 2 2 2 2 2 2 -1 -1 -1 2 2 -1 -1 -1 1 2 -1 -1 2 1 -1 -1 2
O/DDA 2 1 -1 1 0 0 1 0 -1 -1 2 2 2 1 2 -1 -1 -1 2 1 -1 -1 -1 -1 2 0 1 1 1 1 -1 2
NOTE: If more than one rating for any one item was provided,
the highest of the ratings is provided here.
- = Not Rated
2 = Mandatory Requirement
1 = Desirable
0 = Not Rated (Utility Unknown)
-1 = Not Required
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
HIGHEST RATING PER QUESTIONNAIRE ITEM
A
B
C
D
1
2
3
4
5
6
7
8 9
10
11
12
13
14
15
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6 1
ODP/PROCESSING
William E.*
1
1
-1
2
1
2
1
1 -1
2
2
1
1
2
2
1
1
0
2
2
2
0
1
-1
0
1
1
2
2
2
0 2
David M.*
2
-1
-1
2
2
2
2
-1 -1
1
2
0
2
2
2
0
-1
-1
2
2
1
-1
2
1
2
1
-1
2
2
1
-1 2
ODP/SPECIAL
PROJECT STAFF
Dennis M. *
2
2
-1
2
1
0
1
-1 0
2
1
1
1
1
2
-1
-1
-1
2
2
-1
-1
-1
-1
2
-1
1
1
2
1
-1 2
ODP/MANAGEMENT
STAFF
Jay R. *
2
0
0
2
2
1
1
1 0
0
2
1
2
2
2
0
-1
1
2
2
1
-1
2
1
2
-1
-1
2
1
1
1 2
ODP/APPLICATIONS
Division
A
2
0
0
2
1
1
2
0 -1
1
1
1
1
2
1
0
0
0
2
1
0
0
1
1
2
1
0
1
2
1
2 2
Division
B
2
2
0
2
1
1
2
1 -1
1
2
1
2
2
2
0
0
1
2
1
1
1
2
1
2
1
-1
2
2
2
-1 2
Division
C
2
-
-
1
-
-
-
- -1
1
-
1
2
-
2
-
-
1
2
1
-
-
1
1
2
-
-
1
2
1
2 2
Division
D
2
2
-1
1
1
1
2
1 0
1
1
1
1
1
2
1
-1
1
2
2
2
0
1
1
2
1
-1
1
1
1
1 2
Training
2
2
-1
2
1
2
1
0 -1
1
2
1
1
1
1
-1
-1
-1
2
2
2
-1
2
1
1
1
-1
1
1
0
0 1
Dale G.*
2
-1
-1
2
1
1
1
1 -1
1
2
1
1
2
2
1
0
1
2
2
2
1
1
1
2
1
1
2
2
1
0 2
Dennis H.*
2
0
0
2
-
2
1
1 0
1
1
2
2
2
2
0
1
0
2
2
0
0
1
1
1
1
0
1
2
1
0 2
NOTE: If more than one rating for any one item was
provided, the highest of the ratings, is provided here.
- = Not Rated
2 = Mandatory Requirement
1 = Desirable
0 = Not Rated (Utility Unknown)
-1 = Not Required
* = Member of Terminal Requirements Working Group
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
ADDITIONAL TERMINALS REQUIRED FOR FY'78 to FY'83
("WORKING" NUMBERS)
FY
FY
FY
FY
FY F
Y
FY
FY
FY
FY
FY
FY
78
79
80
81
82 8
3
78
79
80
81
82
83
DDO
(ALL)
OGC
2
2
2
2
2
2
IC Staff
-
-
-
-
-
-
DDS &T
IG Staff
1
1
1
0
0
0
RES
2
2
2
1
1
1
O/DDS&T
3
-
-
-
-
-
O/COMPTROLLER
0
0
0
0
0
0
FBIS
4
7
9
12
7 1
0
NPIC
50
50
50
50
50 5
0
OD&E
3
2
0
0
0
0
OSO
-
-
-
-
-
-
OF
4
3
2
-
-
-
ORD
2
2
3
4
4
4
OL
21
17
10
-
-
-
OTS
-
-
-
-
-
-
OMS
1
5
2
2
1
1
OP
3
8
10
10
10
10
OS
2
2
2
0
0
0
OTR
30
15
15
0
0
0
CIA OSP CTR
2
3
3
2
3
3
ISAS
-
-
-
-
-
-
OIA
2
2
2
1
1
1
OC
4
-
-
-
-
-
OCR
16
13
5
5
5
5
O/DDA
1
2
0
1
0
0
OER
12
6
6
3
1
1
OGCR
5
2
2
1
0
0
ORPA
4
5
4
4
4
4
OSI
3
3
3
3
3
3
OSR
18
8
6
5
4
4
to
27
OWI
10
20
3
3
3
3
COMIREX
20
-
-
-
-
-
to
50
TERMINAL QUESTIONNAIRE RESPONSES
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
UI ULMW 1 ILU
ADDITIONAL TERMINALS REQUIRED (FY-78 to FY'83)
FY
FY
FY
FY
FY
FY
78
79
80
81
82
83
ODP/PROCESSING
William E.*
-
-
-
-
-
-
David M.*
6
5
5
5
5
5
ODP/SPECIAL PROJECTS STAFF
Dennis M.*
1
2
2
1
0
1
ODP/MANAGEMENT STAFF
Jay R. *
-
1
-
-
-
-
ODP/APPLICATIONS
Division
A
5
2
2
2
2
2
Division
B
-
-
-
-
-
-
Division
C
-
-
-
-
-
-
Division
D
-
-
-
-
-
-
Training
3
0
0
0
0
0
Dale G. *
-
-
-
-
-
-
Dennis H.*
-
-
-
-
-
-
= No Number Provided
* = Member of Terminal Requirements Working Group
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
%#aA UC.1fVVY4 41.91
Project SAFE Workstation (Terminal) Requirements
(Excerpt from: SAFE Functional Requirements, Dated
1 March 1977)
User workstations will consist of up to seven modular
components. Two or more modular components may be
combined to satisfy the needs of a given user. This
approach will facilitate cost/functional trade-off
analysis, cost-effectiveness, and reliability and
maintenance of each workstation. The modules avail-
able for a workstation include the following:
(1) interactive display module, (2) hardcopy image-
display module*, (3) receive-only, medium-quality
printer module, (4) receive-only, high quality printer
module*, (5) user keyboard module, (6) secure telephone*,
and (7) writing area, storage area for listings and
reference aids*.
Controls and indicators, technical requirements, and
functional requirements are documented for each module.
Functional requirements do not mean that a particular
function must be directly supported by the module under
discussion; rather, the requirements simply address a
means for a user to cause a given action to take place.
Whether that action is implemented in a particular
workstation component, the workstation as a composite,
a computer, or some other facility, is not relevant to
these requirements. Physical requirements for a work-
station are documented in paragraph 7.7; interface
requirements are documented in paragraph 7.8.
An interactive display module will be used for communi-
cating with the system and viewing the display of digital
data from the SAFE data base.
Controls and indicators provided with the interactive
display module will include but may not be limited to:
* Not applicable to the Agency Standard Soft Copy
Computer Terminal Requirements.
-1-
~~ M kt- 9rgrn
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Yuu.J.- ^MVaf ?..Y
(1) ON/OFF switch, (2) FOCUS control, (3) BRIGHTNESS
control, (4) CLEAR-SCREEN switch, (5) CLEAR-MEMORY
switch (if the module includes a buffer memory),
(6) POWER-ON indicator, (7) Transmit light to indi-
cate when the workstation is transmitting data to
the system, (8) ALERT-ALARM indicator which will be
activated by a remote computer, (9) ALERT-ALARM
reset switch, (10) MODE-OF-OPERATION switch, and
(11) GENERAL RESET switch.
7.2.2 TECHNICAL REQUIREMENTS
The following describes the requirements that will be
met by each interactive display module:
(a) Phosphor Color - Characteristics will be chosen
to maximize user's visual comfort.
(b) Highlighting - At least three modes of selective
highlighting will be provided, one of which will
be character or field blinking. Other examples
of highlighting are reverse video, underlining,
and programmable brightness levels.
(c) Read/Write Rates - The workstation will perform
at read/write rates of approximately 1,000
characters per second.
(d) Screen Size - The minimum diagonal screen
measurement will be 12 inches, and the screen
will display a minimum of 2,080 characters
simultaneously, without discernible flicker,
arranged in a minimum of 26 rows of 80
characters each.
(e) Character Set - A 96-character set, uppercase
and lowercase, will be displayable. Further,
some interactive display modules will be
equipped with support for A Programming
Language (APL), and will require the capability
for user-dynamic selection of the APL or
other character sets.
(f) Field Selection - Support will be provided to
facilitate a user's dynamic selection of any
character(s) or screen position(s), by devices
such as a light pen or mouse.
(g) Function Keys - A set of programmable function
keys will be provided to support various technical
or functional requirements and user functions
required by individual users or user groups.
U N_ a};
NCL
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
w411su.rauuai Ma
(h) Alert-Alarm Indicator - Support will be provided to
enable remote activation of the Alert Alarm indicator
whether the interactive display module is powered on
or powered off.
7.2.3 FUNCTIONAL REQUIREMENTS
The following describes the functions that will operate on
each device:
(a) Operational Modes - Support will be provided to
operate the interactive display module in either the
overstrike or insert modes, as selected by the
operator. Overstrike causes the character typed in
at the cursor location to replace the existing
character in that position, and advances the cursor
one position to the right. Insert causes the
character typed to be placed at the cursor location
and, to make room, moves characters to the right
of and below the cursor. During insert operations
fullword wraparound is effected such that as
characters are pushed right by inserted characters,
and the maximum positions of the line are filled, only
full words are moved to the next line.
(b) Delete Character - Support will be provided such that
depression of the appropriate key will result in the
deletion of the character at the cursor location and
cause the text to the right of and below that location
to shift back and up to fill the gap, following the
rules of fullword wraparound defined in (a) above.
(c) Delete Word - Delete word will operate the same as
delete character except that an entire word is
deleted.
(d) Delete Line - Delete line will operate the same as
delete character except that an entire line is deleted.
(e) Move Block - Support will be provided such than an
arbitrary block of text displayed on the screen may be
defined and moved to another designated location on
the screen.
(f) Scroll - Support will be provided to facilitate
scrolling lines up or down, one line at a time. If
the scroll key (either up or down) is depressed for
more than one-half second, the scroll function will
be repeated until the key is released.
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
v' ^"z.7 tuu31 11.1J
(g) Split-Screen - Support will be provided to allow a
display to be split into two parts under user control.
All of the capabilities that apply to the display in
non-split mode will apply to each of the parts
separately.
7.3 HARDCOPY IMAGE-DISPLAY MODULE*
Remote viewing of hardcopy documents requires a high
resolution, display system. Hardcopy images will be re-
quested through the interactive display and keyboard modules.
The requested data will be displayed on the hardcopy image-
display module.
7.3.2 TECHNICAL/FUNCTIONAL REQUIREMENTS
The technical and functional requirements for the hardcopy
Image-Display Module will be specified in the ADSTAR Require-
ments Document or Systems Specification document.
7.4 RECEIVE-ONLY, MEDIUM-QUALITY PRINTER MODULE
A remote, quiet, medium-speed, medium-quality, receive-only
printer will be furnished to produce local hardcopy (from
either of the display modules) at the user's command.
7.4.2 CONTROLS AND INDICATORS
Controls and indicators that will be provided with the
receive-only, medium-quality printer module will include but
not be limited to: (1) ON/OFF switch, (2) paper-jam indicator,
(3) START/STOP-PRINTING switch, and (4) RESET switch.
7.4.3 TECHNICAL REQUIREMENTS
The following characteristics are required:
(a) Speed - The printer will print at a maximum of 120
lines-per-minute.
*Not applicable to Agency Standard Soft Copy Computer
Terminal Requirements.
-4-
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
(b) Character Set - The printer will print a 96-character
set (plus the special characters required in paragraph
4.3.6, Print), uppercase and lowercase, or images from
the hardcopy image module.
7.5 RECEIVE-ONLY, HIGH-QUALITY PRINTER MODULE*
A relatively slow, high-quality, hardcopy printer is required
to produce text suitable for reproduction and publication.
Controls and indicators provided will include but not be
limited to: (1) paper-jam indicator, (2) ON/OFF switch,
(3) START/STOP-PRINTING switch, and (4) RESET switch.
7.5.3 TECHNICAL REQUIREMENTS
The following characteristics are required:
(a) Speed - The printer will print at a minimum of 30
characters-per-second.
(b) Quality - The print quality will be such that it is
suitable for camera-ready copy at least equal to text
typed on an IBM Selectric typewriter.
(c) Character Set - The printer will print a 96-character
set (plus the special characters called for in para-
graph 4.3.6, Print), uppercase and lowercase.
The user keyboard will be provided with each user workstation,
to provide input of user requests and data to the computer
system. Flexibility is required in attaching and interfacing
this module to the other modular components.
*Not applicable to Agency Standard Soft Copy Computer
Terminal Requirements.
-5-
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
ul~ut.t w,, L.: LJ
7.6.2 CONTROLS AND INDICATORS
In addition to the interactive display module controls and
indicators, keyboard controls and indicators for each key-
board will include but not be limited to: (1) a modular
configuration-selection switch capable of specifying the
configuration of the workstation, (2) LOCAL/REMOTE indicator
(controlling all modules), (3) TRANSMIT/RECEIVE indicator,
and (4) character set switch for APL and/or a 96-character
set when needed.
7.6.3 TECHNICAL REQUIREMENTS
Requirements that will be met by each keyboard module are
the following:
(a) Function Keys - There will be support for a minimum
of ten programmable function keys.
(b) Compatability - Each keyboard will be compatible with
the technical requirements of the other modules of
a user workstation.
7.6.4 FUNCTIONAL REQUIREMENTS
A user keyboard will be equipped to accommodate the functions
of each of the other workstation modules.
7.7 PHYSICAL REQUIREMENTS
The following characteristics are required:
(a) Environmental - The workstation will be compatible with
the Agency's general office environment, defined herein
as an enclosed or non-enclosed 100-square-foot area.
The workstation will tolerate temperate ranges, humidity,
and pollutants, such as smoke and dust, found in an
office area.
(b) Size - A workstation will not exceed more than 10-
square-feet of floor or desk space. The shorter side
will fall in the range of 1.5 to 2.5 feet.
(c) Weight - To facilitate maintenance, each modular
component will be manually portable.
-6-
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27: CIA-RDP95-00972R000100170013-9
Declassified in Part - Sanitized Copy Approved for Release 2012/08/27 : CIA-RDP95-00972R000100170013-9
(d) Power - Because the workstations will be installed in
ordinary office space, the capacity to dissipate heat
may be quite limited. Therefore, it is essential to
reduce power dissipated by the workstation to a
minimum. The goal is not to exceed 250 watts.