SUMP TANK QUANITY INDICATION SYSTEM

Document Type: 
Collection: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP89B00980R000200150009-8
Release Decision: 
RIPPUB
Original Classification: 
K
Document Page Count: 
4
Document Creation Date: 
December 14, 2016
Document Release Date: 
October 22, 2002
Sequence Number: 
9
Case Number: 
Publication Date: 
April 19, 1966
Content Type: 
FORM
File: 
AttachmentSize
PDF icon CIA-RDP89B00980R000200150009-8.pdf150.67 KB
Body: 
ENGINEERING STUDY Lockheed Aircraft Corp. 245-1 CHANGE PROPOSAL o DATE 19 April 1966 J AFFECTS : WSPO [] PROJECT NAME OF MAJOR COMPONENT PART OR LOWEST SUBASSEMBLY I PART NO. & MODEL OF TYPE TANK StA SUMP TANK 75F51-50 & G75F136-501R _ TITLE OF PROPOSAL SUMP TA1 C QUANTITY INDICATION SYSTEM NATURE OF PROPOSAL : SEE PAGE 2 REASON FOR PROPOSAL : TO PROVIDE A SUMP TANK FUEL WAN= INDICATION SYSTEM MASON FOR REVI1SION: TO PROPOSE A SYSTEM UTILIZING A CAPACITANCE TYPE QUANTITY INDICATING SYSTZK WITH INDICATOR READCAJT FOR PILOT IN LIBi1 OF FUEL WARNING LIGHT INDICATION. ESTIMATED COST AND TIME INVOLVED : - S ADDITIONAL FUNDING REQUIRED ESTIMATED COST FOR KITS OR PARTS : SEE PAGE ADOITIONAL_FUNDING REQUIRED : . SEE PAGE 5 ITEMS AFFECTED BY PROPOSAL : SAFETY MISSION EFFECT PERFORM- ANCE OPERATING PROCEDURE INTER- CHANGE- WEIGHT OR WEIGHT I TOOLS i SUPPORT MAINTE- NANCE SERVICE LIFE FLIGHT MANUAL MAINTE NANCE TIVENESS ABILITY SAIANCE EQUIPMENT PROCEDURE MANUAL 0 o o 0 0 o ? o El RI EST. MAN/HRS. REQ'D. TO ACCOMPLISH CHANGE IN FIELD SOURCE OF PARTS FOR KIT AVAILABILITY WEEKS AFTER APPROVAL CRAB & LAC SEE PAGE 5 DISPOSITION OF SPARES AFFECTED TO BE REVOF;ICED INITIATED BY APPROVED WSPO ApgpBgr Release 2002/10/31 : C A 0 A-RDP B 9 ~~ 1"i f Approved FdR lease 2002/10/31 CIA-RDP89B00 QI O 0200150009-8 PACE, C)F5 LAC 245-1 ~`' Approved Fo(R4lase 2002/10/31: CIA-RDP89B009O,R000200150009->' 2 of 5 TO PROVIDE A CAPACITANCE TYPE SUMP TANK FUEL QUANTITY SYSTEM. THE SYSTEM WILL CONSIST OF THE FOLLOWING (SIMMONDS PRECISION PRODUCTS, LIQUID ER DIV.) COMPONENTS: B318 TYPE 2 INCH SERVO INDICATOR. INDICATOR WILL BE GRADUATED IN GALS. AND READ FROM 25 GALS. TO 93 GALS. B277 TYPE LINEAR TANK UNIT. BOTH COMPONENTS WILL BE MODIFIED TO SUIT SUMP TANK REQUIREMENTS AND REIDENTIFIED. IN ORDER TO ACCOMMODATE NEW FUEL QUANTITY SYSTEM, AIRPLANE WILL BE MODIFIED AS FOLLOWS: FUSELAGE AN ACCESS DOOR WILL BE INSTALLED IN FUSELAGE BE- ~S. 377 AND F.S. 489.50 ABOVE R.H. SUMP TANK. THIS WILL PROVIDE FOR INSTALLATION AND REMOVAL OF FUEL QUANTITY TANK UNIT _1N SUMP TANK R.H. SUMP TANK P/N 75F51-50R (MODEL C & F) AND P/N 75F136-501 (MODEL G) WILL BE REWORKED TO PROVIDE MOUNTING FLANGE TO INSTALL TANK. UNIT. PLUMBING INSIDE R.H. SUMP TANK WILL BE REROUTED TO CLEAR TANK UNIT AND REIDENTIFIED. A FLOAT SWITCH P/N F73420 WILL BE MOUNTED ON LOWER SUMP TANK ACCESS COVER P/N 75F102. FLOAT SWITCH WILL BE INSTALLED AT 15 GALS. LEVEL. ACCESS COVER WILL BE MODIFIED AND REIDENTIFIED. TANK UNIT SPECIAL ADAPTER WILL BE PROVIDED TO MOUNT QUANTITY TANK ON R.H. SUMP TANK COCKPIT THE L.H. MAIN INSTRUMENT PANEL WILL BE MODIFIED AS EXISTING FLAP POSITION INDICATOR P/N MS28003-1 WILL BE RE- PLACED WITH 3. 1/2 INCH DIA. INDICATOR AND WILL BE RELOCATED AT THE DC LOAD METER PRESENT LOCATION. . DC LOAD METER WILL BE RELOCATED ON CENTER LOWER INSTRUMENT PANEL. THE NEW SUMP TANK QUANTITY INDICATOR WILL BE LOCATED ON L.H. INSTRUMENT PANEL IN AREA PRESENTLY USED FOR FLAP POSITION INDICATOR. Approved for Release 2002/10/31 : CIA-RDP89B0098OR000200150009-8 ~'' LAC 2$5-1 Jf- Approved Fd,ReLpase 2002/10/31 : CIA-RDP89B009SORO00200150009->~g. 3 of 5 Nature of Proposal! (COAL) fi ELECTRICAL POWER WILL BE SUPPLIED FROM THE INVERTER SYSTEM VIA THHER THE NO. 1 OR NO. 2 INVERTERS. PROJECT AIRPLANES A SERVICE BULLETIN WILL BE ISSUED FOR FIELD INSTALLATION. CONTRACTOR WILL BE PROVIDED WITH TWO SPARE SUMP TANKS FOR SERVICE BULLETIN REWORK. TANKS WILL BE ISSUED TO THE FIELD ON A TURN AROUND BASIS. A SERVICE BULLETIN WILL BE ISSUED AGAINST SERIAL 359 TO REMOVE EXISTING SUMP TANK Q ANTITY SYSTEM CONSISTING OF FOUR (4) FLOAT SWITCHES IN SUMP TANK AND FOUR (4) LIGHTS IN COCKPIT. AND REPLACING THEM WITH NEW CAPAC- ITANCE SYSTEM. FOG AIRPLANES A SERVICE BULLETIN WILL BE ISSUED FOR FIELD INSTALLATION ON MODEL C AIRPLANES ALREADY DELIVERET. THE REMAINING AIRPLANES WILL HAVE KITS INSTALLED AT FACTORY DURING CONVERSION. SPARE SUMP TANKS ALL J75 R.H. SUMP TANKS P/N 75F51-50R AND P/N G75F136-5glR WILL BE REWORKED BY DEPOT REWORK ORDER REQJST. ' GROUND HANDLING EQUIPMENT EACH BASE SHALL BE PROVIDED WITH A FUEL (JANTITY GAGE TESTER GENERAL RADIO CO. TYPETTU--68/E SPEC. IL-T-26690 - FEDERAL STOCK NO. 6625-683- 95k7. Approved For Release- 2002/10/31: CIA-RDP89B0098OR000200150009-8 25X1 Approved For Release 2002/10/31 : CIA-RDP89B0098OR000200150009-8 Next 1 Page(s) In Document Exempt Approved For Release 2002/10/31 : CIA-RDP89B0098OR000200150009-8