R & D CATALOG FORM
DATE
15 April 1969
1. PROJECT TITLE/CODE NAME
2. SHORT PROJECT DESCRIPTION
Microdensitometer Modifica-
This project is to develop a digital scan controller
tions (Scan Control and
and a time based. sampling system for the 0 1032T 2
Sampling System)
Trichromatic Microdensitometer now in use at NPIC
3. CONTRACTOR NAME 4. LOCATION OF CONTRACTOR
Declass Review by N
5. CLASS OF CONTRACTOR
6. TYPE OF CONTRACT
Manufacturer
FP
7. FUNDS
B. REQUISITION NO.
9. BUDGET PROJECT NO.
FY 19 68 $ None
FY 19 69 $
10. EFFECTIVE CONTRACT DATE
(Begin - end)
11. SECURITY CLASS.
AA - Confidential
T - Unclassified
FY 19 70 $ None
may 1969 - July 1969
W - Unclassified
_
12. RESPONSIBLE DIRECTORATE/OFFICE/PROJECT OFFICER TELEPHONE EXTENSION
DDI/NPIC/TSSG/DED
13. REQUIREMENT/AUTHORITY The 1032T Microdensitometer is limited in its ability to
(a) scan microscopic areas of imagery without producing extraneous data and (b)
analyze film imagery which exceeds 170 lines per millimeter in resolution.
14. TYPE OF WORK TO BE DONE
Engineering Development
15. CATEGORIES OF EFFORT
MAJOR CATEGORY
SUB-CATEGORIES
Microdensitometry
Precision Measurement
Optical Systems
16. END ITEM OR SERVICES FROM THIS CONTRACT/IMPROVEMENT OVER CURRENT SYSTEM, EQUIPMENT. ETC. The
Contractor will modify the Microdensitometer to: (a) Control the length of the scan
with digital switches and counters instead of microswitches, and. (b) change the
density sampling system from a mechanical base to a time base which will allow a
sampling rate of 10 samples per micrometer (versus the present rate of 1 sample per
17. SUPPORTING OR RELATED CONTRACTS (Agency & Other)/COORDINATION micrometer).
This contract will be run concurrently with a contract to modify a stage for the
1032T Microdensitometer. There is no overlap on these projects. Coordination has
been performed through EXRAND.
18. DESCRIPTION OF INTELLIGENCE REQUIREMENT AND DETAILED TECHNICAL DESCRIPTION OF PROJECT (Continue on addi-
tional page if required) The scan controller consisting of decade counters, switches
and comparison logic will replace the microswitch controls to allow the scan length
to be preset to from 1 micrometer to 1 decimeter. This precise programming of the
scan length will eliminate the extraneous data now produced on small scans and will
reduce costly processing of the data. The sampling system will be modified so that
it will be triggered by a crystal oscillator (the "clock") instead of directly by
the stage movement. The oscillator will allow better control of the sampling rate
and will permit more frequent sampling, thereby reducing the limitations to analyzi
19. APPROVED BY AND DATE ig resolution imagery."
OFFICE
DEPUTY DIRECTOR
DDCI
Approved Fo
Release 2005/05/20 : CIA-RDP78B0