(Sanitized)PRINT PROCESSOR(Sanitized) DIGEST OF INSTALLATION SPECIFICATIONS

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B04747A003000060008-5
Release Decision: 
RIPPUB
Original Classification: 
K
Document Page Count: 
3
Document Creation Date: 
December 28, 2016
Document Release Date: 
November 16, 2001
Sequence Number: 
8
Case Number: 
Content Type: 
REQ
File: 
AttachmentSize
PDF icon CIA-RDP78B04747A003000060008-5.pdf83.2 KB
Body: 
Approved For Release 2002/01/02 : CIA-RDP78B04747A003000060008-5 PRINT PROCESSOR DIGEST OF INSTALLATION SPECIFICATIONS 1. Machine Placement a. INI representative will be on hand to supervise p acement of then the area you designate. The machine. mus e evel in its operating area. b. Machine dimensions are: Width - 3711 Length - 9811 *Height - 8411 Approx. Weight - 1500 lb. *Note: Shipping height will be reduced to 78". c. Operating area should have following clearances: Minimum of 18" on the ends Minimum of 18" on the back side Minimum of 36" on the front or operating side 2. Services a. Electrical requirements: 208 volt, 3-phase, 60-cycle, 4-wire, protected for 40 amperes. Overload protection and disconnect. b. Air: 120 PSIG. 40 CFM Free discharge. Oil free. Note: We have found Quincy Compressor Company, Quincy, Illinois, Model F325, 5 H.P. Motor, 80 gal. storage, 3-phase, 220-440 V, 60-cycle to be adequate. c. Water: Hot - 160?F - 6 gallons per minute. Flow with minimum recovery of 1 gallon per minute. Cold - 6 gallons per minute. Declass Review by NIMA / DoD Approved For Release 2002/01/02 : CIA-RDP78B04747A003000060008-5 STATINTL STATINTL STATINTL STATINTL Approved For Release 2002/01/02 : CIA-RDP78B04747A003000060008-5 - 2 - d. Drain: Floor drain with not less than 1-1/4" line. 3. Atmospheric Controls - Room temperature must be maintained at a level not below 65?F and not in excess of 80?F. 4. Illumination processing room must have appropriate safelighting. We recommend series OC Safelight Filter. Four 25-watt lamps with filters and properly placed should be sufficient. PAS/jh 6/21/63 STATINTL Approved For Release 2002/01/02 : CIA-RDP78B04747A003000060008-5 Approved For Release 2002/01/02 : CIA-RDP78BO4747AO03000060008-5 During the period that the original Processors were introduced for field testing up untl. - e presen time, a number of_chan es have been made in the basic unit. At the request of 0 I am listing the most recent improvements which are now .on p esent models but were not on models tested six months ago. 1. Lens sled has been motorized. 2. Finger stock has been redesigned and now operates by solenoid and an electric footswitch. 3. Hydraulic pump motor has been changed from 1/4 H.P. to 1/3 H.P. and the motor and pump assembly moved to opposite side for easier servicing. 4.' A vertical water knife operated by hydraulic cylinder and cam was incorporated to increase operator's visibility when loading and unloading paper. 5.' Linkage.pin to the turntable solenoid has been enlarged and material specs changed to SAE 4140 steel. 6. Wash shield has been modified to remove the interference at 1:1 enlargement.' 7. Handles.on the negative masking adjustment have been knurled. Approved For Release 2002/01/02 : CIA-RDP78BO4747AO03000060008-5