FEDERAL INSTALLATION SURVEY CHECK LIST
Document Type:
Collection:
Document Number (FOIA) /ESDN (CREST):
CIA-RDP86-01019R000200020033-6
Release Decision:
RIFPUB
Original Classification:
K
Document Page Count:
9
Document Creation Date:
December 9, 2016
Document Release Date:
July 24, 2000
Sequence Number:
33
Case Number:
Content Type:
FORM
File:
Attachment | Size |
---|---|
CIA-RDP86-01019R000200020033-6.pdf | 359.29 KB |
Body:
S. Department of the Inter'
Approved For Releafe.2DOO/0&1&: 1A RgPAf,,,QAQ1g 0gR00020033-6
Middle Atlantic Region
Charlottesville, Virginia
*DOI Waiver Letter In ERU FILE*
Federal Installation Survey Check List
PART I - Information to be supplied by Federal installation personnel.
Note: All questions may not be related to a particular installation.
I. General Description
A. Name of Installation- Printing Services Building
Mailing Address Washington., D.C. 20505
Department
_Agency CIA
B. B=,cawx-'-y4-. t4 t4 -und dCa a.
.
1. Size 59,400 SF
Location: City McLean County Fairfax
State -Virginia
2. Receiving waters for surface drainage Potomac River
3. Waste Discharge Flows:
Domestic
Industrial
Other
4. Population:
Resident
Approved For Release 2000/09/14: CIA-RDP86-01019R000200020033-6
Approved For Release.2000/09/14: CIA-RDP86-01019RQ00200020033-6
5.' Water supply:
Source Falls Church system frora lci a Reservoir
Volume used Unknown, no metering equipment
Treatment provided Normal at Dalecarlia; filtering
within ui ing
II. Waste Treatment and Disposal Facilities and Practices (note: Lay-
out map of sanitary and storm sewers is desirable.)
A. Type of collection system:
1. Sewers:
Separate
Combined
Sanitary Sewer remarks (age, infiltration, deterioration,
Approximately 3 years, new system
Storm Sewer remarks Approximately 3 dears old
2. Sewage pumping stations NONE
Location or
Identification
No. Pumps
& Size
Overflows or
Bypasses
(Yes or No)
If Yes, give
point of
discharge
Alternate
Power Supply*
Avail. Yes/Nv
Other Fail
safe Facil-
ities, alarms,
etc.
Approved For Release 2000/09/14: CIA-RDP86-01019R000200020033-6
Approved For Release.2000/09/14: CIA-RDP86-01019800200020033-6 3?
3. Is installation connected to a municipal system:
Yes X No If no, has the feasibility of
such a connection been considered? Yes No
Remarks:
B. Domestic wastes:
Provide following information for each waste treatment plant
and attach sketch or flow diagram of plant units. (Refer to
page for septic tank - tile field systems.)
1.
Briefly describe area served by system -Immediate Plant
2,
Effluent discharged to (Nacrme of stream)
Potorme River
via Municipal Treatment Plant (Blue Plains)
3.
Design Flow. Unknown GPD
4.
Year constructed Unknown
5.
Performance and loading Unknown
Flow
MGD
BOD
MG/1
Settleable
Solids
MG/1
Suspended
Solids
MG /1
Plant
Reduction
Percent
Raw
Final
Raw
Final.
Raw
Final
Set.
Sus.
Ave.
Peak
Min.
Sewage:
Effluent
Sewage
Effluent
Sewage
Effl.
BOD
Sol.
Sol.
See
Adden
ums
6. Chlorination At Dalecarlia for incoming water and at
Blue Plains for sewage outflow
a.. Are chlorination facilities provided: Yes X No
Blue Plains-
. Points of application
Pre Post Other
c. Is chlorination continuous? Yes No
Approved For Release 2000/09/14: CIA-RDP86-01019R000200020033-6
Approved For ReleaU 2000/09/14: CIA-RDP86-010198000200020033-6
7. Have any complaints been received regarding the operation
of the plant? Yes _ X No
If yes, give date, source and nature of complain
8. Check treatment components that apply to plant. (Blue Plains)
(a)
Bar Screens
(i)
Final sedimentation
(b)
Grit Chamber
(j)
Sand filter
(c)
Comminutor
(k)
Chlorine contact
(d)
Metering Devices
tank
(e)
Primary.Sedimentation
(1)
Holding or
(f)
Imhoff tank
equalization tanks
(g)
Separate
Sludge
(m)
Lagoons
Digestion
Heated
Unheated
(n)
Chemical
Percipitation
(h)
Aeration
(Act.Sludge)
(o)
Sludge Drying
Beds
(p)
Trickling Filters
Are any of the components overloaded? Blue Plains presently overloaded
Recirculation amount and points
Indicate ultimate disposal of digested sludge landfill near Wilson
Bridge
9. Are sewage bypasses provided? Yes X No
If yes, are they sealed or unavailable for use? Yes No
10. Other waste treatment facilities (Septic tanks - tile fields,
septic tank-sand filters, small lagoons, etc.)
Location -
Area served
Design
Capacity V-
Present
Loading If
Effluent
Disinfection 2-1
Remarks
M 'pp*" ?1breFk 9561 0'06 ,4 PCIAeROP86-01019R000200020033-6
2 Complete for those systems having other than ground disposal
5
Approved For Releas2000/09/14: CIA-RDP86-01019`000200020033-6
Are septic tank systems checked for solids buildup on a routine
basis? Yes No
If Yes, indicate frequency
What is the ultimate disposal point of solids removed from
septic tanks
C. Industrial Waste Inventory (including cooling water, boiler
blowdown, air conditioning bleedoff, radiological, etc.) Note:
.Use separate industrial waste check list for large complex
industrial processes.
OURCE
Water
FLOW
GPD _
Waste
Constituents &
Concentrations
m Q/1 or lbs. /day .
Type and
Degree of
Treatmen t
Point of
Di sch
See attached sheets
None in bldg.
To sewer
Remarks:
Amount of chemicals ,added in lbs/day to blowdown: Phosphate Tannin
Sulfites Other
Amount of chemicals added in lbs/day to Air Chromates Acid
Conditioning systems:
other
1. Wastewater from water treatment plant (volume, treatment provided,
and point of discharge). N. A.
Approved For Release 2000/09114: CIA-RDP86-01019R000200020033-6
Approved For Release.2000/09/14 : CIA-RDP86-010198000200020033-6
2. Vehicle washing (number and frequency of vehicles washed, detergent
used and point of discharge). __NONE
Other:
III. Laboratory Facilities, Operating Personnel and Records
A. Operating personnel:
1. Type and Number
Type
Number
Number Certified
or Licensed
Man Hours
Per Week
Superintendent
operators
Laboratory
Technicians
Laborers
2. Are operators at plant(s) 24-hours per day? If "no" give
schedule I
3. Do operators routinely attend short courses or schools? Yes No
B.. Describe laboratory facilities and equipment available.
Approved For Release 2000/09/14: CIA-RDP86-01,019R000200020033-6
Approved For Release 2000/O9/14 : CIA-RDP86-010198000200020033-6
C. Laboratory Test Performed (Specify frequency of tests, daily, weekly, etc.)
Raw
Primary
Mixed
Final
Sludge
Recoil
Test
Sewage
Effluent
Liquor
Effluent
Raw
Supernatant
Dig
Stream
BOD
Suspended.
Solids
Suspended Volatile
Solids
Settleable
Solids
Total
Solids
Volatile Solids
.. '
r
r
pH
Temperature
Coliform Density
Residual Chlorine
Volatile Acids
MB Stability
Other
Other
D. Are operating and laboratory records maintained? Yes
Describe records and data maintained:
Where are they kept?
Approved For Release 2000/09/14: CIA-RDP86-01019R000200020033-6
Approved For Relea a 2000/09/14: CIA-RDP86-0101 8000200020033-6.8
E. Operating manuals and procedures available for operators, including
reference books and standard methods for laboratory analysis: N.A.
IV. Storage and Handling of Hazardous Materials
A. Inventory of Hazardous'Materials (oils, gases, fuels, acids, heavy
metals, solvents, chemicals, and other materials capable of causing
water pollution if spilled).
Type Material
Quantity Stored
Storage Facility
diked, underground,
etc.
Location
Oils, Solvents
300 gallons max.
1 al. cans & 55 gal.
Solvent stor-
age room in
SEE ATTACHED SHE
IT FOR CHEMICAL INV,
drums
'NTORY
_
bldg.
B. What housekeeping methods are used to prevent spills and what procedure
is used for disposal of spilled material? (discuss) Oils and solvents
are absorbed into media, packaged, and shipped out of the plant
with unclassified trash; reusable industrial rags to laundry.
C. Is any mercury stored or routinely used at the installation? Yes?X No
If yes, indicate amount and purpose for which used Approximately 10
pounds;. used for calibrating manometers.
D. Pesticides and Herbicides? Indicate type, amount and frequency used
None, except as introduced into building by GSA exterminators.
Approved For Release 200.0/09/14: CIA-RDP86-01019R000200020033-6
Approved For Release 2000/09/14: CIA-RDP86-01019R000200020033-6 9
V. Improvements Proposed by Installation
Describe any improvements. proposed for water pollution control, prevention
or abatement in the future, and schedule for improvements.
Approved For Release 2000/09/14: CIA-RDP86-01019R000200020033-6