HEADQUARTERS CONFIGURATION MANAGEMENT REQUEST FOR CHANGE

Document Type: 
Collection: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP12-00036R000100240005-0
Release Decision: 
RIPPUB
Original Classification: 
S
Document Page Count: 
58
Document Creation Date: 
December 23, 2016
Document Release Date: 
July 30, 2013
Sequence Number: 
5
Case Number: 
Publication Date: 
March 20, 1986
Content Type: 
REPORT
File: 
AttachmentSize
PDF icon CIA-RDP12-00036R000100240005-0.pdf1.98 MB
Body: 
Declassified in Part- Sanitized Copy Approved forRelease2013/07/30 : CIA-RDP12-00036R000100240005-0 UK t classification HEADQUARTERS CONFIGURATION REFERENCE DATA: RFC NO R0011-05 MANAGEMENT DR NO. NOCNO DATE LOGGED REQUEST FOR CHANGE OTHER REV DATA -nue, Printing & Photography Division Building Facility Baseline Priority: E U R (circle one) Docum=nt Prepared By: Date: 20 Mar 86 office: OL/IND/CMS Phone: 2! Date Approval Rqrd By: Change Type: X 25. PERM 7 TEMP I Office Chief Sig: --/,/CV--. (removal date) 25; Date: (Jr ' , c. r-- Need for Change: When the Headquarters Management Board (HMB) approved the Headquarters CM Plan, it also approved a list of documents that after approval were to be controlled by the Facilities Management Board (FMB). One of those documents is the Printing and Photography Building Facility Baseline Document. The document has been prepared and this RFC proposes its inclusion in Table 2 of the FMB Configuration Control Baseline as originally approved by the HMB. This document will provide a documented description of the important physical characteristics of the P&PD Building on 1 June 1986 and will be used for configuration management of the P&PD Building. Description of Change: Approval of this RFC will place Document H50002, Printing and Photography Buikding Facility Baseline Document under the control. of the FMB. Further, it updates Table 2 to reflect documentation planned for FMB control as some of the originally planned documentation has been consolidated in the Facility Baseline Document. Consequences if Not Implemented: Direction from the Headquarters Management Board will not be followed. Document Numbers of Titles: Specifications/Drawings Affected: H50002 Printing & Photography Building Facility Baseline Document H90001 Headquarters Configuration Management Plan H/W - Fac Affected? Tasks Start/End Dates Actionee Staff Costs $ Cost Update and publish change to the Hdqtrs CM Plan __Apprgy41._ Al,pl + 30 days OL/FMD/CMS Routrle Maintenance Publish and Distribute H50002 . W4Spf.181dajs OL/FMD/CMS Routine. Maintenance ? 4-8.5 SECRET classification Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 R0011-05 H90001 TABLE 2 FMB CONFIGURATION CONTROL BASELINE Title Doc. No. Custodian REQUIREMENTS (TBD) CMS BASELINE DOCUMENTS Original Headquarters Building Facility H50001 CMS Headquarters Site Powerhouse Facility (TBD) CMS Printing and Photography Building Facility 1450002-0(4064 CMS New Headquarters Building Facility (TBD) CMS External Buildings Facilities (TBD) CMS TECHNICAL EQUIPMENT (TBD) CMS TEST DOCUMENTS (TBD) CMS INTERFACE DOCUMENTS (TBD) CMS FACILITY MODIFICATION PLANS (TBD) CMS 15 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 SECRET H50002 PRINTING & PHOTOGRAPHY DIVISION BUILDING FACILITY BASELINE DOCUMENT SECRET Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 *tt:FIET H50002 DOCUMENT NO: H50002 TITLE: PRINTING AND PHOTOGRAPHY DIVISION BUILDING FACILITY BASELINE DOCUMENT REV ' DATE REVBY PAGESAFFECTED* REMARKS FMB INITIAL ISSUE _ per RFC R0011-05 ? Deleted page(s) (d): added page(s) (a): no marking for superseded page(s). 11 SECRET Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 C'.11=1- H50002 TABLE OF CONTENTS 1.0 INTRODUCTION 1.1 Purpose 1.2 Scope and Organization 1.3 Configuration Management Responsibilities 2.0 APPLICABLE DOCUMENTS 2.1 Scope 2.2 Headquarters CM Documents 2.3 Federal Standards 2.4 General Codes and Standards 3.0 PRINTING AND PHOTOGRAPHY BUILDING DESCRIPTION 3.1 Scope 3.2 Location 3.3 General Construction 3.3.1 Size, Form, and Organization 3.3.2 Construction Characteristics 3.3.3 Ceiling Height 3.3.4 Ceiling Materials 3.3.5 Walls 3.3.6 Doors 3.3.7 Floors 3.4 Vault-Type Room Construction 3.4.1 Requirements 3.4.2 Walls 3.4.3 Doors 3.4.4 Other Openings 3.4.5 Alarms 3.5 Stairs and Corridors 3.6 Elevators 3.7 Loading Docks 3-1 3-1 3-1 3-1 3-1 3-1 3-5 3-5 3-5 3-5 3-6 3-6 3-6 3-6 3-6 3-11 3-11 3-11 3-11 iii SECRET npriacsified in Part -Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 ? Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 SECRET H50002 PAGE 4.0 MECHANICAL SYSTEMS 4.1 Scope 4-1 4.2 Heating, Ventilating, and Air Conditioning 4-1 4.3 Chilled Water 4-1 4.4 Steam 4-1 4.5 Plumbing Systems 4-2 4.5.1 Domestic Water System 4-2 4.5.2 Storm Drainage System 4-2 4.5.3 Sanitary Drainage System 4-2 4.6 Chemical Waste Handling System 4-2 4.6.1 Silver Recovery 4-2 4.6.2 Chemical Solids Removal 4-2 4.6.3 Noxious Fumes Removal 4-3 4.7 Pneumatic System 4-3 4.7.1 Compressed Air and Vacuum System 4-3 4.7.2 Negative Pressure System 4-3 5.0 FIRE PROTECTION SYSTEM 5.1 Scope 5.2 Fire Detection 5.4 Fire Extinction 6.0 ELECTRICAL SYSTEMS 6.1 Scope 6.2 Normal Service 6.3 Emergency Service 6.4 Motorised Equipment Service 6,5 Utility Grounding System 6.6 Lightning Ground System 6.7 Lighting 6-1 6-1 6-1 6-2 6-2 6-2 6-2 iv SECRET Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 SECRET 7.0 DATA NETWORKS 7.1 Scope 7.2 Data Grid 7.3 Data Grid Description and Configuration 7.4 Communication Room 8.0 PHYSICAL SECURITY SYSTEMS 8,1 Scope 8.2 Physical Protection 8.3 Alarms 8.3.1 Intrusion Alarms 8.342 Volumetric Alarms 8.3.3 Secure Access Control System (SACS) 8.3.4 Alarm Consoles 9.0 OPERATIONALLY CRITICAL AREAS AND SYSTEMS 9.1 Scope H50002 PAGE 7-1 7-1 7-1 7-1 8-1 8-1 8-1 8-1 8-1 8-1 8-1 9-1 9.2 Photographic Operations 9-1 9.2.1 Tank Farm 9-1 9.2.2 Film and Paper Processing Facilities 9-1 9.;2.3 Film and Paper Printing Facilities 9-1 9.2.4 Photo Copy and Inspection Facility 9-1 9.3 Printing Operations 9.3.1 Electronic Prepress 9.3.2 Camera/ Layout/ Plate Areas 9.3.3 Press and Bindery Areas 9.4 Storage Facilities SECRET 9-10 9-10 9-10 9-10 9-17 neclassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 SECRET H50002 LIST OF FIGURES NUMBER TITLE PAGE 3.2-1 Headquarters Site Overview 3-2 3.3-1 Ground Floor P&PD Building Floor Plan 3-3 3.3-2 First Floor P&PD Building Floor Plan 3-4 3.4-1 CMU Vault Wall Crossection 3-7 3.4-2 'Gypsum Board and Metal Vault Wall Crossection 3-8 3.4-3 Two Hour Fire Rated Wall Crossection 3-9 3.4-4 Standard Interior Wall Crossection 3-10 4.0-1 Mechanical Equipment Room G5 Layout 4-4 6.1-1 Switchgear Room G4 Layout 6-3 6.1-2 MotOrs Control Centers in Room G5 6-4 6.1-3 Power Riser Diagram 6-5 7.3-1 Data Grid Schematic 7-2 7.4-1 Room G16 Floor Plan 7-3 9.2-1 Ground Floor Architectural Layout 9-2 9.2-2 Photographics Operations Equipment Footprint 9-3 9.2.1-1 Tank Farm Architectural Layout 9-4 9.3-1 First Floor Architectural Layout 9-11 9.3-2 Printing Operations Equipment Footprint 9-12 9.3.3-1 Press & Bindery Equipment Footprint (Room 113) 9-17 vi SECRET nprdaccifien in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 SECRET NUMBER 7.4-1 9.2.1-1 9.2.2-1 9.2.2-2 9.2.3-1 9.2.3-2 9:3.1-1 9.3.2-1 9.3.3-1 LIST OF TABLES TITLE Room G16 Equipment List and Requirements Tank Farm Equipment List and Requirements Film & Paper Processing Equipment List and Requirements Film & Paper Processing Equipment List and Requirements H50002 PAGE 7-4 9-5 9-6 9-7 Video Replication Equipment List and Requirements 9-8 Film & Paper Printing Equipment List Requirements and Electronic Composition Equipment List and Requirements (Room 128 & 129) 9-9 9-13 Camera/Layout/Plate Equipment List and Requirements 9-14 Press & Bindery Equipment List and Requirements 9-15 vii SECRET Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 att;IlitT H50002 ABBREVIATIONS & ACRONYMS GLOSSARY ACRONYM/ ABBREVIATION DESCRIPTION. a.c. AEU Amp BTU c.i.p CM CMS CMU COMMO COMSEC CPS CR d.c. DSH FBIS FMB FMD gpm HS NTS HVAC Hz ID IDF KV KVA KW lbs. MCC MDF MDP MHS NEC NHB NSF No O.C. OHB OL PB PBS P&PD PSF RFC Alternating current Air Handling Unit Amperes British Thermal Units Cast In Place Configuration Management Configuration Management Staff Concrete Masonry Unit Communication(s) (5100 Title) Cycles Per Second Condensate return Direct current Department of Safety and Health Farhenheit Foreign Broadcast Information Service Facilities Management Board Facilities Management Division gallons per minute Headquarters Site Headquarters Telephone System Heating, Ventilating, and Air Conditioning Hertz, Identification Intermediate Distribution Frame Kilovolt Kilovolt Amperes Kilowatt Pounds Motor Control Center(s) Main Distribution Frame Main Distribution Panel Message Handling System National Electric Code New Headquarters Building National Sanitation Foundation Number On Centers Original Headquarters Building Office of Logistics Powerhouse Building Public Building Standards Printing and Photography Division Pounds per Square Foot Request for Change viii SECRET npriaccifipri in Part - Sanitized COPY Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for ReleasIg.147/30 : CIA-RDP12-00036R000100240005-0 ACRONYM/ ABBREVIATION DESCRIPTION RFI Rev. RTE SACS Sq. ST Sys TBD TBR UPS VAC VEPCO VSBC VTR WYE Radio Frequency Interference Revision Route (ie. Highway) Secure Access Control System Square Steam System To Be Done/Determined To Be Resolved Uninterrupted Power System Volts, Alternating Current Virginia Electric Power Company Virginia Statewide Building Code Vault Type Rooms Y (Shaped Connection) H50002 ix SECRET Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 *tcHET PARA. NO. 9.2.2 9.2.2 9.2.3 H50002 TBD LISTING DESCRIPTION ORGANIZATION TASKED Table 9.2.2-1, Deep Tank & 20" Paper P&PD .Processor Requirements Table 9.2.2-2, 50" Paper Processor P&PD Requirements Table 9.2.3-2, Documate II, P&PD Special Effects Printer and 30" Paper Cutter Requirements SECRET Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 5ECRET H50002 1.0 INTRODUCTION 1.1 Purpose This publication documents the Printing and Photography Division Building (P&PDB) as it existed on 1 June 1986. This document is under the control of the Facilities Management Board (FMB) and will be maintained by the Configuration Management Staff (CMS)/FMD/OL in accordance with the Headquarters Configuration Management Plan, H90001 and the applicable documents in paragraph 2.0. Changes affecting the characteristics described in this document will require the prior preparation and submission of a Request for Change (RFC) form for approval by the FMB. 1.2 Scope .This document describes the building structure, facilities, essential networks, systems/networks and operationally critical areas of the P&PB. This document serves as the "as built" baseline to be used in the configuration control of the P&PB: The scope of this document includes the contiguous five (5) feet extending beyond the outer walls of the building. Other facilities on the Headquarters campus are described in separate baseline documents. 1.3 Configuration Management Responsibilities The Technical Monitor (TM) for this document is the Chief, FMD/OL. The Configuration Management Staff (CMS)/FMD/OL will provide camera-ready pages that document all changes that are submitted and subsequently approved by the FMB. CMS will publish and distribute the change packages. 1-1 SECRET npriaccifipri in Part - Sanitized COPY Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 CIA-RDP12-00036R000100240005-0 *tt;FILT 2.0 APPLICABLE DOCUMENTS 2.1 Scope 1150002 This section lists those documents that govern the design, construction, And characteristics of the P&PB. 2.2 Headquarters CM Documents H90001 Headquarters Configuration Management Plan 1180001 Agency Space Allocation Document CM-01 Request for Change (RFC) Instruction CM-02 Configuration Management Staff Instruction CM-03 Controlled Document Preparation Instruction 2.3 Federal Standards 2.4 PBS-P3425.85 PBS-P3430.1 PBS-P7000. 2A GSA PBS-P5900.2 DSH1910 MIL-STD-461B NACSIM 5100A CFR FF 1-70 Part 1630 FTMS 372 No number General Codes Criteria for Federal Office Buildings, Jan. 1977 Quality Standards Design and Construction Assignment and Utilization of Space, Rev. Oct. 1977 Federal Management Property Regulations Accident and Fire Prevention, July 1960 Occupational Health and Safety Standards Electromagnetic Emission and Susceptibility National COMSEC Information Memoranda, Compromising Emanations Laboratory Test Requirements Standard for the Surface Flammability of Carpets and Rugs Critical Radiant Flux for Carpet Systems Fire Protection Manual- CIA/DA/OL/SD and Standards NFPCA RP-1 NEC NSF VSBC Standard Practice for the Fire Protection of Essential Electronic Equipment Operations National Electric Code National Sanitation Foundation, Codes and Standards Virginia Uniform Statewide Building Code 2-1 :SECRET nni-laccifiinri in Part - Sanitized Copy Approved for Release 2013/07/30 CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 SECRET H50002 3.0 PRINTING AND PHOTOGRAPHY BUILDING DESCRIPTION 3.1 Scope The following paragraphs describe size, form, construction, and . operational facilities of the P&PDB. 3.2 Location The P&PDB is located adjacent to the northwest corner of the New Headquarters Building (NHB) in the Headquarters site in Langley, Virginia. Figure 3.2-1 provides an overview of the site. 3.3 General Construction 3.3.1 Size, Form, and Organization The P&PDB is classified by the BOCA Code as a use Group B, business with a Group 2 ordinary hazard type occupancy. It is a two-story rectangular structure measuring 325 feet by 120 feet for a total of 64,500 net square feet incorporated in two floors. The P&PDB accommodates the production requirements of an Agency-wide printing and photographic service. The first floor has most of the printing operations facilities and the ground floor houses the photographic operations. There are some administrative/office areas in the building and a variety of equipment rooms supporting the physical plant. See Figures 3.3-1 and 3.3-2 for the ground floor and first floor plans respectively. 3.3.2 Construction Characteristics The P&PDB is constructed of finished reinforced concrete. It has a columnar grid spacing of 25'-0" (north-south) by 30'-'.0" (east-west). The columns are designed to support two additional general office use floors above the first floor. 3.3.3 Ceiling Height The nominal unraised floor to unfinished ceiling height is 12 feet. Nominal dropped ceiling height above unraised floors is 10 feet. 3-1 SECRET nprdaccified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 V GW PARKWAY ?,4 ENTRANCE 14 'or 9 . 2a ANT ENNA PUMPING STATION ali RTE. 123 ENTRANCE WEST %PARKING STRUCTURE MOTOR POOL GARAGE HAMM ERM I LL FIGURE 3.2-1 HEADQUARTERS SITE OVERVIEW Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 tri o) 0 0 X GROUND FLOOR P&PD BUILDING FLOOR PLAN Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Ui 0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 SECRET FIGURE 3.3-2 FIRST FLOOR P&PD BUILDING FLOOR PLAN 3-4 SECRET Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 SECRET H50002 3.3.4 Ceiling Materials Except for the Press Branch and the Warehouse fire-rated acoustic . tile suspended ceilings are used on the first floor. All suspended ceilings have factory applied non-shedding plastic coated panels, perforated for acoustic dampening'. The Press Branch and the Warehouse areas are open to the concrete ceiling above, and painted. Ceilings in the ground floor are snap on metal tile, except 'for room G32 which has regular suspended ceiling tile. 3.3.5 Walls Except for concrete masonry walls and the fire walls that outline the stairs and elevators, perimeter walls are readily removable, metal - partitions extending from the floor to the dropped ceiling. The wall above the suspended ceiling is constructed from 9-11 gauge expanded metal welded to 118 thick steel angle frame with the spot welds placed every six (6) inches. The metal partitions are secured to the bottom channel or frame with a .1/4 inch carriage bolt placed two (2) feet on center or peened on the protected side. The metal channel is anchored to the slab with 1/4 inch carriage bolts placed two (2) feet on center. See Figures 3.4-1 through 3.4-4 for, specific details. 3.3.6 Doors Standard wooden doors and metal frames are used throughout the P&PDB. All doors are a minimum of 3 feet wide by 7 feet high. Technical areas are accessed through double doors with a nominal opening of 5 feet x 8 feet. All doors accessing service areas and lavatories include automatic closure mechanisms and keyed locksets. 3.3.7 Floors Concrete floor structures throughout are two-way waffle slab with a 4 1/2 inch conduit overlay slab. Other than in photoprocessing areas which are covered with chemical resistant quarry tiles, floors are covered with vinyl asbestos tile. 3-5 SECRET npriacsified in Part- Sanitized CopyApprovedforRelease2013/07/30 CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 *tt.:11ET H50002 3.4 Vault-Type Room Construction 3.4.1 Requirements The security requirements governing the construction of Vault-Type Rooms (VTR) for open shelf storage of classified material have been followed in the P&PDB. 3.4.2 Walls All VTR perimeter walls are built from true floor to true ceiling. The walls are constructed from 9-11 gauge expanded metal welded to 1/8 inch thick steel angle frame with the spot welds placed every six inches. The steel Angle frame is securely anchored to the true floor and true ceiling by using a 1/4 inch bolt into the slab on 16 inch centers. Movable metal partitions are used for interior walls throughout the P&PDB. Because the metal partitions only extend from the floor to false ceiling, the wall above the false ceiling is constructed from 9-11 gauge expanded metal according to the specifications described in the preceeding paragraph. The metal partitions are secured to the bottom metal channel or frame with a 1/4 inch carriage bolt placed two feet on center and peened on the protected side. The metal channel is anchored to the slab with 1/4 inch carriage bolt placed two feet on center. 3.4.3 Doors Perimeter doors are 1.3/4 inch metal fire doors having an UL-approved rating of one and one-half hours. All VTR primary doors are equipped with a security approved combination lock and a personnel control (Simplex) lock as optional hardware. All secondary doors are solid wooden doors and are equipped with approved sliding deadbolts or panic hardware. 3.4.4 Other Openings All vents and ducts, which have openings exceeding 90 square inches are grilled with 9-11 expanded metal. The space around the vent or duct as it passes through an expanded metal partition does not exceed three inches. 3-6 SECRET npr.lassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 SECRET EXISTING CONC. FLOOR STRUCTURE COMPRESSIBLE INCOMBUSTIBLE MATERIAL W/ 1/4 POLYSULFIDE / SEALANT CONT. BOTH SIDES OF MALL WIRE TIES SUSPENDED ACOUSTIC CEILING PERIMETER ANGLE CONTINUOUS 3/4" CEMENT PLASTER 4' OR 6' CM WALL RESILIENT VINYL BASE EA. SIDE OF PARTITION FINISH FLOORING EXISTING CONC. FLOOR SLAB STRUCTURE FIGURE 3.4-1 CMU VAULT WALL CROSSECTION 3-7 SECRET H50002 neclassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 SECRET WALL DETAIL OF VAULT TYPE ROOM EXISTING CONCRETE WAFFLE SLAB POWDER ACTUATED FASTENERS @ 12" O.C. SUSPENDED CEILING SYSTEM 16 GA. METAL STUDS @ 16" O.C. WITH CONT. 9 GA. EXPANDED METAL . TACK WELDED @si- " O.C. 5/8" GYP. BO. TYPE "X" 2?LAYERS POWDER ACTUATED FASTENER @ 2'-0" O.C. EXISTING CONCRETE FLOOR SLAB H50002 FIGURE 3.4-2 GYPSUM BOARD AND METAL VAULT WALL CROSSECTION 3-8 SECRET Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 SECRET 1150002 UIST. CONC. iLOOR STIIUCTURE STUD TRACK-FASTEN TO c_ OF CONC. STRUCTUPE WITH POWDERICTUATED FASTENERS FASTER STUD TRACKS TOGETHER 16" O.C. STAGGERED 3 S/8" METAL STUDS t 16" ,O.C. SUSPENDED ACOUSTIC CEILING SYSTEM 2 LAYERS' 5/8* TYPE X. GYPAID. SECURE CONTINUOUS STUD TRACK M/ FINDER ACTUATED FASTENERS RESILIENT VINYL USE EA. SIDE OF PARTITION FINISHED FLOORING EXISTING CONC. FLOOR SLAB I STRUCTURE FIGURE 3.4-3 TWO HOUR FIRE RATED WALL CROSSECTION 3-9 SECRET npriassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 *tcliET EXIST. CONC. FLOOR STRUCTURE WIRE TIES FASTEN STUD TRACK TO SUSPENDED CEILING TEE 3 5/8" METAL STUDS IP 16' O.C. SUSPENDED ACOUSTIC CEILING SYSTEM 5/86 TYPE 'X GYP. BD. SECURE CONTINUOUS STUD TRACK W/ POWDER ACTUATED FASTENERS RESILIENT VINYL BASE EA. SIDE OF PARTITION FINISHED FLOORING EXISTING CONC. FLOOR SLAB STRUCTURE FIGURE 3.4-4 STANDARD INTERIOR WALL CROSSECTION H50002 3-10 SECRET npriacsified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 CIA-RDP12-00036R000100240005-0 DtLaitT H50002 3.4.5 Alarms All VTRs are equipped with an intrusion alarm system furnished and installed by the Office of Security (OS). Power is provided by a 120 VAC dedicated power duplex outlet located above the primary entrance into the VTR. A Belden No. 8723 transmission line running inside a 3/4 inch conduit is provided between a junction box located above the suspended ceiling by the primary door, to the alarm junction box located in the OHB "E" corridor - electrical closet which ultimately terminates in Room 1F19. 3.5. Stairs and Corridors There are two (2) sets of stairs in the P&PD Building connecting the ground and first floors. One set is located next to the first floor entrance lobby and the other Set is located just south of the northeast corner of the building. Both sets of stairs exit onto.interior corridors located along the east side of the building. In the ground floor there is an east-west 6' corridor extending ? between the Emergency Exit located by the southern end of the west wall of the P&PDB and the elevator. A short corridor at these intersection runs north and provides access to rooms G16 and G65. See Figure 9.2-1 in Section 9 In the first floor ther are two east-west and two north-south corridors located in the northern half of the P&PDB as shown in Figures 9.3-1 and 9.3-2 in Section 9. 3.6 Elevators There is one elevator south of the main lobby of the building connecting the two (2) floors for use as both personnel and light freight vertical transportation. This elevator rated at 4,500 lbs. capacity has a platform size of 6'x 6 1/2' and door opening size measuring 5' x 7'. A hydraulic ram located underneath the elevator drives it. 3.7 Loading Docks There is one loading dock located along the southeast corner of the building. This dock has the capacity to service one tractor trailer. Clearance restriction is 10'. A 20,000 lb. capacity leveller is available to facilitate the delivery of equipment which cannot be unloaded directly onto the dock. All deliveries must pass through a doorway with a 9' x 10' size opening. 3-11 SECRET nne-Imccifiinn in Part - Sanitized Copy Approved for Release 2013/07/30 CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 CIA-RDP12-00036R000100240005-0 SECRET H50002 4.0 MECHANICAL SYSTEMS 4.1 Scope This Section describes the major mechanical systems (services) provided in the P&PDB. These include the HVAC, Chilled Water, Steam and Plumbing Systems. Figure 4.0-1 indicates the location of the equipment located in Room G5 which supports the mechanical systems. 4.2 Heating, Ventilating, and Air Conditioning Two 50 tons (521105 CFM) Kopper Inc. Air Handling Units (ABUs) located in Mechanical Equipment Room (G5) serve the building. In ADP equipment areas, such as rooms 128 and 129, local AHUs supplement the additional cooling load The method of air supply to office areas facilitates office partitioning. Air is supplied through air vents located next to the lighting fixtures. Generally, air return from the room to the ceiling plenum space is also returned through the lighting fixtures. This provides a "clean" ceiling system and reserves alternate ceiling tiles for sprinkler heads, speakers, occupancy sensors, etc. Generally, labs and other special spaces are served from the central air handling units. Certain areas with critical air balance requirements are served from these systems using constant volume reheat boxes. Some labs or special spaces are served by local dedicated air handling systems. Fume hood exhaust fans are located in the roof to insure a negative pressure in exhaust ducts within the building. Computer areas are served by two air systems, one overhead and one underfloor. This permits portions of the area to be used for office space as required by the user's changing needs. The underfloor air system is designed to handle that portion of the internal heat load which is in excess of the office cooling load requirement. Thus, both systems operating together provide ventilating and air conditioning for the computer areas. 4.3 Chilled Water Approximatly 21 gpm of 50? F. chilled water for the central AHUs in the Mechanical Equipment Room (G5) is provided via 8" diameter underground pipe runs entering by the southeast corner of the ground floor. 4.4 Steam Steam service for the building is provided via a 6" underground pipe run which enters by the southeast corner of the ground floor. 4-1 SECRET nne-ImccifiPri in Part - Sanitized Copy Approved for Release 2013/07/30 CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 SECRET H50002 4.5 Plumbing Systems 4.5.1 Domestic water System The water service source for the P&PDB comes from a 12" perimeter loop around the building.. Two service connections are made to this loop, oce at the north and one at the south end of the building. These are interconnected within the building to facilitate maintenance. To provide proper operating pressures within the building, variable speed constant pressure booster systems serve the upper levels of the building. Domestic hot water is generated by shell and tube heaters which have the domestic water in the shell and steam in the internal tubes. All systems of domestic hot water have circulation pumps to 'assure relatively constant temperatures throughout the systems. 4.5.2 Storm Drainage System Drainage from the building roof areas flows by gravity to the site storm systems. Foundation drainage is pumped to connect to the site storm systems. 4.5.3 Sanitary Drainage System Waste from all fixtures and equipment within the building flows by gravity to the site sanitary system, exiting the building at its northeast corner. 4.6 Chemical Waste Handling System 4.6.1 Silver Recovery Silver Recovery from black and white film processing is effected by a single unit located in the Chemical Tank Farm in room G7. Recovery from color film processing is effected locally with 10 gallon capacity units located near the processors. 4.6.2 Chemical. Solids Removal Removal of noxious chemical solids from Cibachrome color film processing is effected with a 20 gallon capacity extractor located near the processor. There are no other sources of noxious chemical solids in the P&PDB. 4-2 SECRET n.rincQifipri in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 SECRET H50002 4.6:3 Noxious Fumes Removal Besides the normal ventilation of rooms by the HVAC system, ozone and other noxious gases are removed from photo processing and chemical storage rooms with ducts venting out through the roof of the facility. 4.7 Compressed Air and Vacuum System The Compressed Air and Vacuum System supplies both a positive pressure (i.e., compressed) air and a negative pressure (i.e. vacuum) air, used in the operation of photographic and printing equipment. Figure 4.0-1 depicts the layout of the Mechanical Equipment Room G-5 and shows the location of the operationally critical equipment. 4.7.1 Positive Pressure System Two 60 HP Quincy model QLPS-6,0 compressors supply high-volume low pressure air and two 58 HP Ingersall Rand model 200H compressors supply high pressure air to the operations areas noted in section 9 herein. The low pressure system draws 44.0 KVA, 208 V, 3 phase 60 Hz power. The high pressure system draws 88.0 KVA, 208 V, 3 phase 60 Hz power. 4.7.2 Negative Pressure System ? Two 40 HP Quincy model QSVI vacuum pumps service the operations areas noted in section 9 herein. They draw 44.0 TWA, 208 V, 3 phase 60 Hz power. 4-3 SECRET nprdaccifien in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 *tt;FIET H50002 FIGURE 4.0-1 MECHANICAL EQUIPMENT ROOM G5 LAYOUT .4-4 SECRET Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 SECRET 450002 5.0 FIRE PREVENTION SYSTEMS 5.1 SCOPE This section provides information on the present fire prevention measures existing in the P&PDB . This information is provided in the areas of. detection fire alarms, central control equipment, local control panels, sprinkler and Halon systems. 5.2 FIRE DETECTION The predominant detection devices method used throughout the building are thermal detection units. They are non-restorable heat sensitive detectors that operate at approximately 135 degrees Fahrenheit. The detector senses the heat released from a fire and causes a signal to be sent to the monitoring control panels. This signal is also transmitted to the central equipment in Room 1F19 of the OHB. Supervisory personnel are notified so that appropriate action may be taken. In data processing and switch rooms, Smoke detectors are utilized. Ionization detectors are used in the above floor spaces to sense products of combustion while photoelectric detectors are used below floor for sensing smoke from the cables. 5.3 FIRE ALARMS There are manual breakglass stations for initiating a fire alarm signal throughout in the building. The audible alarm system is composed of bells usually placed above the manual breakglass stations and in strategic locations for occupant awareness. The operator in Room 1F19 of the OHB alarms these bells by switches on a console. 5.4 FIRE EXTINCTION There are wet pipe sprinklers located throughout both floors of the P&PD Building. There is also an ample supply of portable fire extinguishers, strategically located throughout both floors of the P&PD Building. 5-1 SECRET noriaccifipri in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 SECRET H50002 6.0 FTECTRICAL SYSTEMS 6.1 Scope This section describes the Electrical Systems characteristics and related services which provide normal and emergency power; and lightning and technical equipment grounding. See Figures 6.1-1 through 6.1-3 for a description of the Electrical System. 6.2 Normal Service One thousand (1,000) KVA of 60 HZ three phase power at 208/120 Volts is supplied to the P&PD Building from the normal feeder bus breaker # BA off of the North transformer. The feeder enters the building along the southwest corner and terminates at a 1,000 KVA transformer in G4, the transformer room. Five hundred (500) KVA Of 60 HZ three phase power at 208 Volts are tapped from the existing bus above, to feed a 208 (3 Phase) to 480/277 Volts dry type transformer located within the new 480 Volt Switchgear. From the equipment room, power is distributed via electrical conduits to the local electrical power panels. 6.3 Emergency Service One thousand (1,000) KVA of 60 HZ three phase power at 208 Volts is supplied to the P&PD Building from the emergency feeder bus breaker # 8B off of the South transformer. The feeder enters the building along the southwest corner and terminates at a 1,000 KVA transformer in the transformer room (G4). . Five hundred (500) KVA of 60 HZ three phase power at 208 Volts are tapped from the existing bus above to feed a 208 (3 Phase) to 480/277 Volts dry type transformer located within the new 480 Volt Switchgear. From the equipment room, power is distributed via electrical conduits to the local electrical power panels. 6-1 SECRET nprlaccifiari in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 CIA-RDP12-00036R000100240005-0 6CLAILT H50002 In the worst case, i.e., technical power being supplied directly from the main bus (in the bypass mode), through transformation conforms to. the following characteristics: 60 Hertz o Voltage: 208/120, 3-phase, Wye o Voltage tolerance: +/- 10% o Frequency: 60 Hz +/- 0.5% o Voltage variation, line-to-line: less than 10% of the arithmetic average of the three phases o Harmonic content: less than 5% 6.4 Motorized Equipment Service Electrical power to mechanical equipment loads is handled by motor control centers. These centers are located west of column 3K in room G5 and are fed directly from the the Switchboards in room G4. Motor Control Centers A and B are fed from the 480 Volts Switchboard. They control the four Vacuum Pumps located in room GS. The other motor control centers; MCC 1 and MCC 2, are fed from the 208/120 Volts Switchboard in room G4. They control the Elevator, exhaust fans throughout and various pumps and compressors. 6.5 Utility Grounding System Utility grounds are used for all of the equipment and applications not serviced by technical power. The basic system consists of power safety grounds and ground risers of down conductors which connect these safety grounds to an earth ground system. The safety ground consists of a 2" x 1/4" copper bus bar running along the south wall of the Transformer Room. The bus bar is connected to a number of 5/8-inch copper ground rods driven approximately 20 feet into the ground. The bus bar is also connected to bus bar loops surrounding two transformer bays. All utility grounds and neutral, through their respective panel boards and transformers, tie into the safety ground system. 6.6 Lightning Ground System A counterpoise ground system which encircles the outside of the building perimeter is. provided for use with the lightning system down conductors. The counterpoise ground system is connected to the substation ground mats and the building structural steel in order. to achieve an effective equi-potential ground mass. 6.7 Lighting Power for lighting is supplied by 277 volts, single phase 60 Hertz circuits throughout the P&PB. The selection and placement of fixtures throughout the P&PB provides the recommended levels of illumination, listed in the IES Lighting Handbook. 6-2 SECRET nne-ImccifiPri in Part - Sanitized Copy Approved for Release 2013/07/30 CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 CIA-RDP12-00036R000100240005-0 D.C. PANELBOARD GENERAL ELECTRIC TYPE 'NAB'. MOUNT ON I 5/8' CHANNELS 2000A 30.3W. 1/4'X6* BUS DUCT EX. 4*X8' CONCRETE CURB 500 KVA 208V.A TO 480/277V Y -4, 30.4W DOUBLE ENDED SUBSTATION) DISCONNECT SWITCH TYPE COMBINATION STARTER IN NEMA-I ENCLOSURE WITH 3P-30A N.F.S.S. AND NEMA SIZE 1 MAGNETIC STARTER. H.O.A. SWITCH, PILOT LIGHT AND I20V. FUSED CONTRCC TRANSFORMER. 1008 kVA XFMR 1000 kVA XFMR 2000A 30 3W I/ AVX6'BUS DUCT BELOW EXISTING 400011,30.4W BUS DUCT 71-111.4 FIGURE 6.1-1 SWITCHGEAR ROOM G4 LAYOUT CONNECTED TO 3P-20A C/13 IN EX. PANEL A. TO AUXILIARY CONTACT IN EX. EXHAUST FAN MOTOR STARTER. EX.41300A.BlIS DUCT SWITCHGEAR FRONT EXISTING 208/120V. UAW SWITCHING GEAR CONCRETE PAD CONCRETE PAD ? PANEL 'A*, 208/120V. 30,4W. GENERAL ELECTRIC CO. TYPE 'CCI3*. VII fin WIN 1111=11111111111 nariaccifipri in Part - Sanitized Copy Approved for Release 2013/07/30 CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 SECRET MCC A 480V.-30.3W. FRONT MCC B 480V.30,3W. -- VACUUM PUMP CONTROLLER (TIP.) 40HP 480V VACUUM (TYPICAL FOR 4) 2-3M. 310350 MCM & 164 GM. IN EACH .MECHANICAL EQUIPMENT ROOM 24')(24?PULL BOX NEW TWO-SINGLE SECTION MOTOR CONTROL CENTERS MCC A. AMO MCC B EXISTING MOTOR CONTOL CENTERS MCC-1 & MCC-2 81 A2 B2 MCCA MCC8 MCCA MCCB FIGURE 6.1-2 MOTOR CONTROL CENTERS IN ROOM G5 6-4 SECRET H50002 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 WWMK PROTtClat 0?).---NETTAIN PROTECTOR II 1 1 MORA. 3 EIPP. RUCOUCT .KMMOMWM MWMTNCC-IP PRNOR CONTROL mamma-, Meek NUS RUC nenama 614 TC1,4 BEM 0 Ul FIGURE 6.1-3 POWER RISER DIAGRAM Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 SECRET H50002 7.0 DATA 'NETWORKS 7.1 Scope This section describes the data grids and local area networks operating in the P&PDB. 7.2 Data Grid The data grid provides the means of communicating between remote terminals in. the P&PDB and the communications equipment on the ground and first floors of the-OHB. 7.3 Data Grid Description and Configuration All cables in the data grid are RFI protected twisted/shielded cable. Cable runs between terminal boxes, pull boxes, communication cabinets, and/or peripheral equipment, are routed in metal conduits. The above said boxes, cabinets, and equipment are RFI protected themselves. The overall configuration of the Data Grid in the P&PDB is schematically illustrated in Figure 7.3-1. 7.4 Communications Room Room G16 houses the communications and secure telephone equipment in the P&PDB. The communications equipment provides interconnection between the computer mainframes and Secure Telephone Switch in the OHB and the data terminals and secure telephone switch in the P&PDB. Figure 7.4-1 is an . architectural layout of .Room G16 showing the Communications equipment and secure telephone switch. Table 7.4-1 lists the electrical and cooling services requirements for the equipment in Room G16. The secure grid connects the secure telephones and data terminals within the P&PDB to the secure telephone switch and communications equipment in Room G16. 7-1 SECRET npriaccifipri in Part - Sanitized COPY Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 C PO ITg 4 PR 1 . I f -tipRagi Jim IPM1M111111111111 111Vsiw-11111111111111 r I IF L5 1:-- 11111111 I ? ? N6 DATA' Lin/Ks A o' -P/P; ? DATA Pi'P 1 FIGURE 7.3-1 DATA GRID SCHEMATIC , sepaRE TELEPriortES Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 RMS. Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 SECRET POWER FILTERS DISCONNECT SWITCH 100 AMP, 30 SEE NOTE I SEE NOTE 2 VENT BARRED r I I _ _ - ? _ : I. I ' 1, ER -5 KG-34 ER4 M-48 ER- MEGA MUX ER- 2' DATA P/P ?t II I r L I 1150002 ? COP - 32 BLOCK CONSOLE . --- 1 L iu2T0X0 1 11 . ? T - r" ER-6 TRUNK 11 11 P/P c___ NOTES : I. ISOLATION TRANSFORMER 15 KWA, 1 0 , TYPE 208.-120/240 VAC 2. ?AC DISTRIBUTION PANEL GE -12 POSITION 100 AMP, 10. 3. PP a 0 RED POWER PANEL SCHEDULE EQUIPMENT SKR SKR EQUIPMENT v(ft ? wft UTX 1200 KG-34 (ER5 ) 3 MEGA MUX (ER3) 5 ER2 7 UTX CONSOLE 9 2 TRUNK P/P 4 M48 ( ER4 ) 6 8 DATA P/P (ER1) 10 12 FIGURE 7.4-1 ROOM G16 FLOOR PLAN I I ' II 7-3 SECRET Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 TABLE 7.4-1 ROOM G16 EQUIPMENT LIST AND REQUIREMENTS GO CO 3, rq -4 MEG. TYPE AND DESCRIPTION MEG. QUANTITY COOLING REQ'TS (EACH) LECTRICAL PWR REQ'TS EVA (EACH) Ill -4 CFH KBTU/HR AIR KBTU/HR WATER 120 VAC 1P,60HZ 208 VAC 1P,60KZ 208 VAC 3P,60HZ 208 VAC 3P,4001E PANELS UTX-1200 SWITCH TELCO 1 14.0 4.1 CONSOLE TELCO 1 1.0 0.3 M48 GFE 2.1 0.6 TDM 1258 GFE 1.5 0.4 KG-34 GFE 1 0.2 0.1 DATA PATCH PANEL GFE N/A N/A TRUNK PATCH PANEL GFE 1 N/A N/A Ln Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 5tcHET H50002 8.0 PHYSICAL SECURITY SYSTEMS 8.1 Scope TWA section describes the control of access to the P&PD Building. 8.2 Physical Protection The entire restricted space is maintained as a security premise. Routine access is through a single pedestrian entrance and foyer. The foyer is large enough to accommodate a guard station and reception area, with ' accommodations for less than ten visitors. Access to the space beyond the guard is through two SACS controlled badge readers. 8.3 Alarms 8.3.1 Intrusion Alarms All emergency exit doors, perimeter doors, and doors accessing - designated restricted areas have, local alarms. These alarms are annunciated at the central alarm console. The local alarms on the emergency doors equipped with panic bars are battery operated. 8.3.2 Volumetric Alarms OS approved Volumetric Alarms are installed in all restricted access VERs. 8.3.3 Secure Access Control System (SACS) All doors which access a technical or office area from a common corridor are protected by a SACS. This system is of the card (Badge) reader type. The control console is under the control of the Office of Security. A secure/access switch is installed in the protected area by the door that it controls. The alarm readouts are integrated with the alarm console. 8.3.4 Alarm Consoles All security, safety, and utility consoles referenced in this document are integrated, to the extent possible, into a single read-out display and remoted to a control center in the Security Office complex in the OHB. 8-1 SECRET npriacsified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 SECRET H50002 9.0 OPERATIONALLY CRITICAL AREAS AND SYSTEMS 9.1 Scope This Section describes areas and systems in the P&PDB that are critical to operations. These are areas which have activities, functions and/or equipment that are vital to the mission of the agency. 9.2 Photographic Operations The Photographic Operations located on the ground floor consist of VTRs and photographic laboratory facilities. See Figure 9.2-1 for a floor. plan of the ground floor showing the operationally critical areas shaded and Figure 9.2-2 for the critical equipment therein. 9.2.1 Tank Farm The Tank Farm, located in VTRs 0-6 and G-7, contains the Chemical Mixing System described in Table 9.2.1-1. 9.2.2 Film and Paper Processing Facilities VTRs 013, 614, 015, G18, G19, G21, 026, 032, G36, G36A, G37 and G44A are dedicated Film Processing Facilities. Tables 9.2.2-1 and 9.2.2-2 list the physical characteristics of the operations significant equipment in these VTRs. 9.2.3 Film and Paper Printing Facilities VTRs G20, 024, G25, 026A, G29, G30, G31, G34, G39, G40, G42, G43, 044, 045, 046, 048, 049, 050, G51A, 054, 055, G56, G57, G59, G60, 062, G63, G64 and.078 are dedicated Paper Processing Facilities. Tables 9.2.3-1 and 9.2.3-2 list the physical characteristics of the operations' significant equipment in these VTRs. 9.2.4 Photo Copy and Inspection Facility The Photo Copy and Inspection Facility is located in Room G65. 9-1 SECRET npriaccifien in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 TRANS FORMER SW I TCHG EAR ROOM T ROOM? tio FIGURE 9.2-1 GROUND FLOOR ARCHITECTURAL LAYOUT Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 or Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 EXTEX SILVER FILM DUPLICATOR EXTBC DIAZO G ROLL FILM DUPLICATOR DEEP TANK PROCESSOR 70MM CUSTOM CAMERA () CIBACHROME COPY SYSTEM HOPE 50* PAPER PROCESSORS "0 LIPSNER SHIT FILM ?zoos [SYSTEM HOPE 24E6 COLOR FILM PROCESSOR DOMINATE Il ALLEN HOPE 52' ROLL F LH PAPER PROCES ORS PROCESSOR KREI ITE B&W PAPER PRO ESSOR CUSTOM VIDEO BROWN REPLICATI COPY SYSTEM CAMER HOPE MINILAB SON! 10'c ALLENGE UI T? PAPE CLEA CUT T XEROX PAPER DUPE FIGURE 9.2-2 PHOTOGRAPHIC OPERATIONS EQUIPMENT FOOTPRINT Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Ln Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 SECRET I! CONTROL PANEL -Ir-7CHILL r-I WATER- UNITJ,41 TANK 0 I 0.9 TANK DECK nu) _J BATHS o cr TANK FARM 1-- z o u TANK FARM = TANK FARM 1-?I FILLER /RESERVOIR 06 1 4Nik ?411SINK I .14F MIX TANKS BALLY FILM REFRIGERATOR I. FIGURE 9.2.1-1 TANK FARM ARCHITECTURAL LAYOUT 9-4 SECRET H50002 SILVER RECOVERY E-4 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 :.CIA-RDP12-00036R000100240005-0 TABLE 9.2.1-1 TANK FARM EQUIPMENT LIST AND REQUIREMENTS WEIGHT COOLING REQ'TS (EACH) I ELECTRICAL PWR REQ TS KVA (EACH) MFG. TYPE AND DESCRIPTION MFG. I QUANTITY CHEMICAL MIXING SYSTEM HOUSTON FEARLESS I N/A KILO KBTU/HR KBTU/HR 1120 VAC 1208 VAC 1208 VAC 1208 VAC LBS. I CFM AIR WATER I1P,60HZ I1P,60HZ I3P,60HZ 13P,400HZ PANELS TEN CHANGES N/A IPER HR I N/A - 166.4 - ROOM GS Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 0 x Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 TABLE 9.2.2-1 FILM AND PAPER PROCESSING EQUIPMENT LIST' AND REQUIREMENTS MEG. TYPE AND DESCRIPTION WEIGHT KILO MFG. QUANTITY LBS. =LING RUM (PACK ROLL FILM PROCESSOR ALLEN PRODUCTS 1 IN G13 1.2 KBTUIHR KBTU/HR 1120 VAC CFM AIR WATER 1P,60HZ TEN CHANGES PER HR 20.0* ELECTRICAL PWR REQ TS KVA TEACH) 268 VAC- 208 VAC 1208 VAC 1P,60HZ 3P,60HZ 13p,400HZ PANELS 7.1 SILVER FILM DUPLICATOR EXTEK MICROSYS 1 IN G14 N/A 10.0 3.6 DIAZO ROLL FILM DUPLICATOR FIIM CLEANING SYSTEM EXTEK MICROSYS 1 IN G15 .2 LI PS SMITH CORP. 1 IN G19 1.0 4.2 1.8 N/A 4.6 B&W FILM PROCESSOR HOPE INDUST'S 1 IN G26 1.9 TEN CHANGES PER HR N/A 8.3 DEEP TANK PROCESSOR TBD 1 IN G18 TBD TBD TBD 20- PAPER PROCESSOR KREONITE 1 IN G21 TBD TBD TBD TBD TBD LG1 PC]- TBD TBD TBD TBD TBD npriacsifiAri in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 TABLE 9.2.2-2 FILM AND PAPER PROCESSING EQUIPMENT LIST AND REQUIREMENTS (Room G32) MFG. TYPE AND DESCRIPTION I MFG. QUANTITY WEIGHT KILO LBS. COOLING REQ'TS (EACH). ELECTRICAL PWR REQ'TS KVA (EACH) CFM KBTU/HR AIR KBTU/HR 1120 VAC -1-20a VAC WATER 11P,6082 11P,60HZ 208 VAC 3P,60HZ 208 VAC 3P,400HZ PANELS CIBACHROME COPY SYSTEM J ILFORD/ IDAINIPPON 2 1.4 7 N/A 4.0 PG4 MINI-JAB HOPE INDUST'S 1 1.7 TEN CHANGES PER HR 7.5 I- 10.4 PG5 C-41 FILM PROCESSOR HOPE INDUST'S 1 1.9 TEN CHANGES PER HR N/A 8.3 PG4 24" E6 COLOR FILM PROCESSOR HOPE INDUST'S 1 2.6 TEN CHANGES PER HR N/A 7.7 PG4 50", PAPER PROCESSOR HOPE INDUST'S 1 TBD TBD TBD TBD TBD 0 npriacsified- in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 TABLE 9.2.3-1 VIDEO REPLICATION EQUIPMENT LIST AND REQUIREMENTS (Room G34) MFG. TYPE AND DESCRIPTION VIDEO REPLICATION SYSTEM MFG. QUANTITY WEIGHT KILO LBS. COOLING REQ TS (EACH) ELECTRICAL PWR REWTS KVA (EACH) CFM KBTU/HR KBTU/HR AIR WATER 120 VAC 1P,60HZ 208 VAC 208 VAC 1208 VAC 1P,60HZ 3P,60HZ 13P,400HZ PANELS CUSTOM N/A N/A 32.8 9.6 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 CIA-RDP12-00036R000100240005-0 TABLE 9.2.3-2 FILM AND PAPER PRINTIYG EQUIPMENT LIST AND REQUIREMENTS I I MFG. TYPE I AND DESCRIPTION MFG. QUANTITY WEIGHT KILO LBS. COOLING REQ TS- (EACH) I ELECTRICAL PWR REQ'TS KVA (EACH) CFM nCBTU/111 AIR V K8TU/HR 1120 VAC WATER 11P,60HZ 1208 VAC 11,060HZ 1208 VAC 3P,60HZ 208 VAC 31,0400HZ 1 PANELS B&W PAPER PROCESSOR KREONITE 1 IN G65 N/A - 19.5 - I - 6.2 - - PG3 ULTRASONIC CLEANER SONICOR INSTRUM'T 1 IN G65 .9 TEN CHANGES PER HR N/A - 4.6 - - TBD PAPER DUPLICATOR XEROX 1 IN G65 2.4 - 13.7 - - 8.3 - - TBD 52" TRACK PAPER PROCESSOR HOPE INDUST'S 1 IN G68 2.7 TEN CHANGES PER HR 5.5 . - F - - 9.4 T - PG3 DOCUMATE II DOCUMATE 1 IN G78 TBD TBD TBD - TBD - - TBD 312 COLOR PRINTER KODAK 1 IN G44 - 5.0 - 1.8* - - - TBD SPECIAL EFFECTS PRINTER OXBERRY 1 IN G60 TBD - TBD TBD - - - TBD 30" PAPER CUTTER CHALLENGR 1 IN G65 TBD TBD N/A TBD - - T TBD * 1.6 KVA of 208 VAC ALTERNATE nprlacRifiari in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 SECRET H50002 9.3 Printing Operations The Printing Operations located on the first floor consist of VTRs and Printing Services Facilities. See Figure 9.3-1 for a floor plan of the first floor showing the Operations Critical areas shaded, and Figure 9.3-2 for the footprint of the critical Equipment therein. 9.3.1 Electronic Prepress The Electronic Prepress is located in Rooms 128 and 129 in a raised floor computer environment. Table 9.3.1-1 lists the physical characteristics of the operations significant equipment therein. 9.3.2 Camera/Layout/Plate Areas Rooms 123, 127, 130, 139, 140, 141, 142, 143, 144, 145, 147, 148, 149, 150, 151, 152, and 153 are dedicated to Camera/Layout and Plate composition activities. Table 9.3.2-1 lists the physical characteristics of the operations significant equipment therein. 9.3.3 Press & Bindery Areas Rooms 112 and 113 are dedicated to Press and Bindery operations. Table 9.3.3-1 lists the physical characteristics of the operations significant equipment therein and Figure 9.3.3-1 shows the location and footprint of these equipment.. 9-10 SECRET Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 kV/ N 0 ? fii / rlifnili op 1E TRALLIoN 4.0 / AREAAL i . 127 r ,4r is / AA Al r jr 4, A00 W&OT OPERATIONALLY CRITICAL AREA , , or --aggoi mit / -1 i23 er ,docitres, 52 a WASHROOM Of / IP I , i III: A ? ? 1 c. 611 ,53 . n INII M I 0 _ V J --- 184 :: i I All t _ , _ * ww,*A m w ? w w ?J WASHROOM FIGURE 9.3-1 FIRST FLOOR ARCHITECTURAL LAYOUT Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 0 0 P.3 Ca CI -4 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 FIGURE 9.3-2 PRINTING OPERATIONS EQUIPMENT FOOTPRINT Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 TABLE 9.3.1-1 ELECTRONIC COMPOSITION EQUIPMENT LIST AND REQUIREMENTS (Rooms 128 & 129) MFG. TYPE AND DEScRIPTIoN ATEX SYSTEM CDC SYSTEM APS 5 Xy VISION WEIGHT I COOLING REQ'TS (EACH) KILO ICBTUFW RBTU/HR MFG. I QUANTITY I LBS. CFM AIR WATER T ONE IN ATEx I RN 129 _ _ 62.7 _ [ 1 ONE IN CDC I Rm 129 - 15.0 - 120 VAC IP,60HZ 9.6 ELECTRICAL 1208 vAC- IIP,60HZ 1 8.8 AWR REQ'TS KVA (EACH) 208 VAC 208-VAC T 3P,60H2 3P,400Hz PANELS 4.4 ONE IN ROOM 129 ONE IN ROOM 129 ONE IN AUTOLOGICI RH 129 ONE IN Xy VISION RM 129 30.0 8.8 ONE IN ROOM 129 30.0 8.8 ONE IN ROOM 129 LASER1TE v - PLATE mAx111 sCIENTIFC TWO IN R14128 30.0 3.6 (440 VAC) 23.0 IN mECH,L ROOM N.) Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 TABLE 9.3.2-1 CAMERA/LAYOUT/PLATE EQUIPMENT LIST AND REQUIREMENTS MFG. TYPE AND DESCRIPTION MFG. T WEIGHT KILO QUANTITY LBS. COOLING REQ'TS (EACH) CFM KBTU/HR KBTU/HR AIR WATER CP-340 SCANNER HELL ONE IN RM 130 N/A 120 VAC 1P,60HZ ELECTRICAL PWR REQ' TS KVA (EACH) 208 VAC 208 VAC 208 VAC 1P,60HZ 3P,60HZ 3P,400HZ PANELS 3.0 TBD 32-ML B&W FI114 PROCESSOR PAKO ONE IN R/4143 44 C CRONALITH PROCESSOR DUPONT ONE IN R/4145 300 42" FIIM PROCESSOR KREONITE ONE IN RM 150 11.5 TBD TBD 12.5 5.8 T , 6.6 TBD TBD TBD Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 TABLE 9.3.3-1 PRESS AND BINDERY EQUIPMENT LIST AND REQUIREMENTS (Room 113) MFG. TYPE AND DESCRIPTION MFG. QUANTITY WEIGHT KILO LBS. COOLING REQ'TS (EACH) ELECTRICAL PWR REQ'TS KVA (EACH) CFM KBTU/HR AIR KBTU/HR WATER 120 VAC 1P,60HZ 1208 VAC 11P,60HZ 1208 VAC 13P,60HZ 208 VAC 3P,400HZ PANELS MIEHLE COLOR PRESS M.A.N. ROLAND 1 67.5* N/A I 188.0 ROOM G5 9900 PAPER DUPLICATOR XEROX [ 2 3.3 26.6 I 10.4 1 PG3(B) 25" FAVORITE PRESS ? MIEHLE 2 7.0 N/A 1 I 6.3 PG 3(A) PLATEN CHANDLER PRICE 1 3.5 N/A 1 1 6.3 PG 3(A) TBD HEIDEL- BERG 1 8.7 N/A 1 1 I 12.5 TBD. TBD TOMAC 1 .6 TBD I 4.1 PG3(B) TBD A-B DICK 1 .6 N/A 1.8 I 1 PG3(B) VERTICAL PRESS . MIEHLE 1 3.0 N/A I 6.2 PG 3(A) ENVELOPE PRESS TBD 1 1.2 N/A I 6.2 PG 3(B) MIEHLE 40" 1 COLOR M.A.N. ROLAND 1 N/A I 36.0 TBD MIEHLE 40" 2 COLOR M.A.N. ROLAND 1 N/A 1 50.0 TBD ? 50" MIEHLE M.A.N. ROLAND 1 N/A I 89.0 TED npriacsified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 TABLE 9.3.3-1 PRESS AND BINDERY EQUIPMENT LIST AND REQUIREMENTS (Continued) MFG. TYPE AND DESCRIPTION MFG. QUANTITY WEIGHT KILO LBS. COOLING REQ TS (EACH) ELECTRICAL MR REQ'TS KVA (EACH) .CFM KBTU/HR AIR KBTU/HR WATER 120 VAC 1P,60WZ 208 VAC 1P,60MZ 208 VAC 3P,60HZ 208 VAC 3P,400HZ PANELS GOSS WEBB PRESS SYSTEM ROCKWELL 1 47.0 MINOR 1.8 52.0 P9 52" CUTTER LAWSON' 3.0 MINOR 6.6 P1/14 SADDLE/GATHERER/ STITCHER DEXTER 1 0.6 MINOR - ? 15.4 P2/20 PERFECT BINDER MULLER MARTINI 1 0.4 10" EXHAUST MINOR 6.6 P1/4 3 KNIFE TRIMMER BOHLEN - BERG 1 4.0 MINOR 8.8 P1/27 18" FOLDER' HULLER MARTINI 1 1.5 MINOR 3.3 TBD 40" FOLDER BAUM 1 3.5 MINOR 6.6 P1/25 12 STATION COLIATOR HARRIS/ MACEY 1 1.2 MINOR 6.6 P1/20 PADDER KANSA 1 0.8 18" EXHAUST 8.8 P2/23 SIDEB1NDER HARRIS/ MACEY 1 1.5 MINOR 6.6 P1/15 MULTIBINDER HARRIS/ MACEY 1 1.0 MINOR 6.6 P1/15 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 N3ONIS3OIS 3-KNIFE LAWSON 52' CUTTER 1 MARCEY C LATOR 112 I MARCEY THIIND I PADDER LAWSON 52' CUTTER W 13 PRESS A DICK ESS XEROX 9900 104 MIEHLE VERTICAL PRESS HEIDELBERG PRESS 0 MIEHLE 40' 2 COLOR 113 MIEHLE COLOR PRESS MIEHLE 25' FAV. PRESS ENVELOPE PRESS XEROX 9900 _1 JOMAC DRYER 1111111001111 rnTiiii Firm COLOR I PRESS CONTROLS CHANDLER PRICE PLATEN ? 103 FIGURE 9.3.3-1 PRESS & BINDERY EQUIPMENT FOOTPRINT (Room 113) 1"1 neclassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0 0 Declassified in Part - Sanitized Copy Approved for Release 2013/07/30 : CIA-RDP12-00036R000100240005-0 SECRET H50002 9.4 STORAGE FACILITIES The critical storage rooms in the.P&PB and the Figure number of the architectural layout locating each room are: Room 103 Solvents Figure 9.3-1 Room 104 Bulk Materials & Supplies Figure 9.3-1 Room G6 Chemicals & Walk-in Freezers Figure 9.2-1 Room G75 Paper & Film Cold Storage Figure 9.2-1 9-18 SECRET Declassified in Part - Sanitized Copy Approved for Release 2013/07/30: CIA-RDP12-00036R000100240005-0