f%f%f% nn-inn
Approved For ReLea
OPTIONAL M NO. 10
Memorandum
TO : The Files:
.FROM
DATE:28 February 1963
SUBJECT: Trip Report - Demodulator Test Program with 25X1A5a1
1. Project Description:
This project will compare the field performance of the
seven-bit Barker code system 07 -17), a conventional FSK
Demodulator (Northern 174) and a linear demodulator incor-
porating the Page Decision Threshold Computer.
2. Contractual Inform*tion:
a. Initial Cost:
b. Initiation Date: 1 July 1962
c. Completion Date: December 1962 Extension: 1) 1 March 1963
d. Deliverable Items: A Comprehensive 2) 1 April 1963
Engineering/Field Test Report
3. Date of Meeting: 28 February 1963
4. Place of Meeting :
5. Persons Attending:
enc
Non-Agency
6. Contractor's Performance:
a. On Schedule and Expected to Remain So : Yes
b. Within Obligated Funds and Expected to Remain So: Yes
c. Satisfactory Technical Progress: Yes
7. Project Status:
A visit was made to the contractor's facility at
Virginia to witness on-the-air testing of the three demodulators.
The equipment set-up and test plan were being followed as described
Approved For Release 2000/08/27 CIA- 00010065-0
Approved For Release 2000/08/27 : CIA-RDP78-02820A000900010065-0
SUBJECT: Demodulator Test Program with 25X1A5a1
in the previous trip report dated 21 January. At the time of
the visit, the contractor had been running the tests for four
days. Test results indicate that the demodulators "stack-up"
Subsequent to a telecon with on 4 March 1963, the
formal on-the-air testing was scheduled to continue until
22 March. However., the project engineer recommended during
the telecon that the testing be terminated within the next
several days. The data that was being obtained was becoming
increasingly repetitive and no great service would be performed
by continuing to take additional data of this type. It was
felt that the effectiveness of each demod had clearly been
demonstrated at this point. On 5 March _ was informed to
stop the tests and begin preparation of a comprehensive engi-
neering report describing the tests and performance of each
demod.
Distribution:
R&D Subject File
Inspection Branch/PD/OL
R&D Lab
OC-OS
FSB
Monthly (2)
EP Chrono
Approved For Release 2000/08/27 : CLcRDP78-02820A000900010065-0