9 (2), 281- (1-1 O-OV/115-59-10-14/29
AUTHORS: Kulikovskiy, L.P., Kemeshis, P,P.
TITLE: A Vectormeter With Two Degrees of Freedom
PERIODICAL: Izmeritellnaya tekhnika, 1959, Nr 10, pp 28-32 (U'SSR)
ABSTRACT: The above-mentioned vectormeter was developed by the
Kafedra avtomaticheskikh i telemekhanicheskikh ustroy-
stv Kuybyshevskogo industrialnogo instituta (Chair of
Automatic and Telemechanical Installations of the.Kuy-
byshev Indu8trial Institute) (Figs 1, 2 and 3). The ba-
sic parts of the vectormeter are the meter of the vec-
tormeter, the phase transducer and the electric corr-
ector. The technical data of the vectormeter are: vol-
tage 220 v; maximum value of measured current, 5 milli-
amperes; maximum value of measured voltage 1.1 v;frame
resistance, 200 ohm; the current constant 3 - 10-5
amp/min; induction in the backlash 620 gauss. The vec-
tormeter was developed for the godograph of the curr-
ent vector. A detailed description and the analytical
method of calculations are given in the article. There
Card 1/1 are 4 diagrams and 2 Soviet references.
PHASE I BOOK EXPLOITATION SOV/5622
Kulikovskiy, Longin Frantsevich, and Aleksandr Mikhaylovich
M6_1_iW--ShbLkhhazarov - ---~
Kompensatory peremennogo toka (Alternating-Current Potentiometers)
Moscow, Gosenergoizdat, 1960. 175 P. 10,000 copies printed.
Ed.: N. V. Levitskaya; Tech. Ed.: K. P. Voronin.
PURPOSE : This book is intended for technical personnel concerned
with electrical measurements and the development of means of
automation. It may also be useful to students In advanced
courses on automatic, electrical measuring#and telemechanical
instruments and devices.
COVERAGE: The book discusses a-e potentiometers with manual and
automatic balancing, general problems of a-c compensating
measurements, compensating circuits and their elements,and
the practical application of potentiometers. According to
the authors this book is the first attempt to present a
comprehensive investigation of a-c potentiometers. They have
Card 1/7
RNBON, W
IM12
Alternating-Current Potentiometers SOV/5622
based it on existing Soviet and non-Soviet materials, as
well as on the practical experience of the Azerbayd2hanskiy
Institut neili i khimii im. Azizbekova (Azerbaydzhan Petroleum
and Chemistry Institute imeni, Azizbekov) and the Kuybyshevskiy
industriallnyy institut (Kuybyshev Industrial Institute). No
personalities are mentioned. There are 118 references: 79
Soviet, 22 German, and 17 English.
TABIE OF CONTENTS:
Foreword
Introduction
3
Ch. I. Measuring Circuits of A-C Potentiometers
A. A-C Potentiometers of the Cartesian-
Coordinate Type
1. Cartesian-Coordinate potentiometers with a phase-shifter
Card..~
IULIKOVSKIT,-L,,Y,; TSIBIR, A.L.
Single-rheochord rectangular-coordinate-type a.c. co"nsator, Iza,
tekh. no.3:19-22 Mr '60. (MIRA 13:6)
Ollectronic instruments)
SVEIJCHAjjSYJY
) A.D.; ARONOV, L.I.; SHMSOV, MI.A.; &CUDOV, A.I.;
SUCHILINIYOV, S.I.; IWITRIK) S.I.; CHMO, N.M.; ZIER,13V, I.T'.;
-SISOYANA G.A.; KOZIM, V.S.; KULIKOVSKUP L.F.; INOVIKOV, O.Ya.
---------------
Professor S.I. Tellnyi. Elektrichestvo no.10:89 0 160. (MIW~ 14:9)
(Tellnyi, Stepan Ivanovich, 1890-~
PHASE I BOOK EXPLOITATION SOV5534
Kulikovskiy, Longin Frantsevich
Induktivnyye izmeriteli peremeshcheniy (Induction Displacement Indicators) Moscow,
Gosenergoizdat, 1961. 279 p. Errata slip inserted. 12,000 copies printed.
Ed.: A.G. Mamikonov; Tech. Ed.t K.P. Voronin.
PURPOSE.s This book is intended for technical personnel engaged in designing means
of automation and telemechanics,as well as for students studying elements of auto-
matic devices and electrical measurement of nonelectrical quantities.
COVERAGEs The book describes electrical measurement of nonelectrical quantities
and the automatic checking of induction-type converters, and gives their basic
theoretical relationships. Basic efficiency criteria for these converters and
methods of calculating some of them are discussed. The book is based on the in-
vestigations carried out by the author at the Azerbaydzhanskiy industrialin
institut imeni Azizbekova (Azerbaydzhan Industrial Institute imeni AzizbekoVj
Kaunnsskiy politekhnichookiy institut (Kaunas Polytechnic Institute), Kuybyshev-
skiy industriallnyy institut (Kuybyshev Industrial Institute), and Institut
Card J/ 9
Induction Displacement Indicators
SOV/5534
avtomatiki i telemekhaniki AN SSSR (Institute of Automition and Telemechanics,
AS USSR). Certain data from the dissertations of K.D. Kolesnikov, K.Yu.
Ostashovichus, and A.A. Kolltsov were used in Chs. 6p 8, and 9. The author
thanks the following personst A.A. Stepanyans V.M. Belousovp and the entire faculty
of the Kafedra avtomaticheskikh, telemekhanicheskikh i elaktroizmeritellnykh
ustroystv (Department of Automatic, Telemachanicalp and Electrical Ybasuring
Devices) of the Kuybyshev Industrial Institute imeni V.V. Kuybyshev; and V.A.
belyayev, A.P. Slyunyayev, and K.L. Kulikovskiyj who reviewed the manuscript
and prepared the illustrations. There are 44 referencesall Soviet.
TABLE OF CONTENTS:
Foreword 3
Ch. 1. Review of the Basic Methods of Electrical Measurements of
Displacements
1. Methods of converting various physical quantities into linear and
angular displacements 5
Card-2/9
MALIYEV, Yuriy Nikolayevich; KV-41KO'VSK,11., L.F.,,.doktor tekhn.
nauk, retsenzent; STEPANIA11, A.A.,, k-and. tekhn. nauk,
obshchestv. red.; PETROFOL'$UtA#JL-Ys,, redal.DURA69VA,
V.M., tekhn.red.
[Electronic calculating macbines] Elektronnye matematiche-
skie mashiny. Kuibyshev, Kuibyshevskoe knizhnoe izd-vo,
1963. 217 p. (MIRA 17:2)
KULIKOVSKIY, L.F.; LIKHTTSINDER, B.Ya.
Balancing of the measured vector quantity in comparing devices.
Izn,.takh. no.501-34 my 163. (MIRA 16:10)
KULIKOVSKIY, L.F,; MOROZOVI V.K.
Galvanometer-type photomagnetic compensator. Izv.vys.ucheb.zav.;
prib. 6 no.6:21-28 163. (KIRA 17:3)
1. Kuyby.,,IicvBkiy politeklinicheskiy institut imeni Kuylvsheva.
Rekomendovana kafedroy elektroizmeritelinoy tekhniki.
KULIKOYSKIY , Longin Frantsevich- KELIK-SHAKIINAZAROV, Aleksandr
-- - I 1 1. ..' Mi WWI .. . ... **-. -.--AAbTf!bV169, Semen Girchevich; SELIBER,
ylovich;
Boris Abolevich; WIKONOVp A.G., red.; BO.IUNOV, N.I.p
tekhn. red.
[Galvanometric compensators] Gallvanometricheskie kom-
pensatory. Moskva, Izd-vo "Energiia," 1964. 279 p.
(MIRA 17:3)
KULIKOVSKIY, L.4., S-14"PANY121, A.A., ;~~HVEPNC`I, S.Ye.; .31-111N, II.A.
Device for measurement of dri'llIngy raten, lo~.-_rlrg and hoistin.ry
of" tool6, and well-shaft drilling. Izv.vys.uchcyb.znv.; nof't' .1 gaz
5 no.12:87-92 162. (~n_A P7-4)
1. KuybY3hevskly politvkhnicheskiy institat Imem, Kuybyslhevri.
GRIGOV Ev, A.S.; KULIKOVSKIY, L.F.
........ ..
Photoelectric emplifier with a high ration of the usp, of the o,-E)n
angle of an electric meter. Friboro:troenie no.9;22-21+ 5 164.
IW4-e_ A
ACCESSION NR: AP4041346 S101 15/64/000/005/OU31/0033
AUTHOR: Kulikovskiy, L. F,; Grigor yev. A. S.; Grigorovskiy, B. X.
TITLE: Photocompeneation electrometer
SOURCE: lzmeritellnaya tekhnika, no. 5, , 1964, 31-33
TOPIC TAGS: electrometer, radial electro.de electrometer, - photucompeneation
I electrometer
ABSTRACT: At the zero position of an electrometer movable plate, the light from
lamp L (see Enclosure 1) equally illuminates two photovaristors P;L and P. . When
the measurand is applied to the electrometer input, the plate will move until the
measurand is compensated by the voltage drop across feedback resistor r due to
current I (the photova ris tor -currents difference). Formulas for designing suc'~
an electrometer are supplied, An experimental electrometer combined with a
standard photo-unit (part of an F- 117 galvador toter) had these characteristics:
Caid._11/3
ACCESSION NR: AP4041346
7
range, 100-1,000 mv., input resistance, 4 ohms: damping time, 0.5 sec ar
less; over-all error, 1. 5-0. 5% for 100- 1, 000 mv, respectively; the readout
instrument may have a full-scale current of 0. 1-1. 5 ma with an internal
a resistance of 3 kohms or lose. Orige art. has; 3 figures and ZZ formulas.
ASSOCIATION: Kuyby*shevskiy polit,ekhnichookiy institut (Kuyby*ohev
Polytechnic Institute)
!:SU33MITTED: 00 ENCL: 0 1
SUB CODE:.- EE NO REF SiOVI 000 OTHERt 000
;Card' .2/3
11. A, -Q
ACCESSICH NRj AP4041346
Keasu
raW 4
Output
4w
Ps
twP
maDSURE101
ACCESSION NR: AP4045921 S/0119/64/000/009/OOZZ/0024~
AUTHOR: Grigoryev, A. S. (Engineer); Kulikovski L. F. (Doctor of
technical sciences, Professor)
TITLE: Photoelectric amplifier with a high coefficient of utilization of the
electrometer aperture angle.
SOURCE: Priborostroyeniye, no. 9, 1964, 22-24
TOPIC TAGS: electrometer, photoelectric amplifier, photoelectrometer
,%BSTRACT: A linear-type electrometer with an aperture of 1. 50 is used in a
nc%v photoclectrometer instrument (see Enclosure 1) in which, at zero reading,
the light beam covers one-half of each of two photoresistors connected in
ro
pposition (FSK-7, b "differential photoresistor"). The coefficient of utilization
Of the aperture is 35"io. Other tecimical data given: number of t;tationary plates#
2 pairs; plate height, 16 mm; ID and OD, 5 and 16 rrim, respectively; voltage
Card 1/3
'ACCESSION NR: AP4045921
range, �50 mv; current range. 10712 amp; quantity range, 5 x 16"'t coulombs;
rated output current, 3 ma; error, 1.5% or less. A standard F-117 photounit
and a negative feedback are used in the instrument. Orig. art. has: 5 figures,
17 formulas, and I table.
ASSOCIATION: Kuyby*shevskiy politekhnicheskiy -institut. iKuyby*she4
Polytechnic Institute)
SUBMITTED: 00 ENCL: 0 1
SUB CODE: 1Ej EG NO'REF SOV: 002 OTHER: 000
Z/3
ard
C
ENCLOSURES
41
46
r
Rft14
I" Vol
41 -41
A photoelectrometric amplifier and its
characteristics
0 in the coefficient of utilization of aperture
U0 U03 RI 171"
U"t - U0
Card 313
j
) -14 '1 !I-., !~ , , , - *4 ~ -
~ ~ r I I
I I .t
---. ) flizures rnd'4 formulas.
. -11
-O'd 2 / 3
0 u t
~66 0WT(.l)/Z'dA(h)
L __?~
ACCESSION NR: APS021435 UR/0146/65/008/004/0031/0035
621.316.721
AUTHOR: Kulikovskiy, L. F.i Korganova, 0. G.
~TITLE: Current and voltage stabilizers with weight-type reference element
SOURCE: IVUZ- Priborostroyeniye, v. 8, no. 4, 1965, 31-35
TOPIC TAGS: voltage regulatorl current stabilization, photoresistor
ABSTRACT: The authors describe'the operation of the dc voltage stabilizer shown ini
~fig. 1 of the Enclosure. The supply voltage U is fed to the input of a bridge
in I
made up of the two resistors R, and RZ and the two photoresistors F, and Fa . This~
bridge operates in unbalanced conditions. Current I flows through the load circuitli
aDd frame I of a permanent-magnet converter, creating torque. An opposing moment
The
is created by weight 2 which is fastened directly to one side of the frame.
:maximum angle of r*tation of the frame is 0.05* which is determined by limiters 31
;so that the counter-torque is a constant value. If the equilibrium of the system
lis upset by a change in U r R mirror 4 is tilted and redistributes the
in 0 load'
Card 1/3
.L 295r--66
~ACCESSION NR: APS0211135
ight flux from illuminator 5 between photoresistors F1 and F2 in such a way that
:the current I is brought back to the original value and equilibrium is restored.
The stabilizer operates reliably between 80 and 320 volts with a stabilizing current
(without amplification) of 5 ma, a load resistance of 10, and stabilization factor
Of 5260. The relative error with a voltage change from 8 to 320 volts is 0.05%. If
the permanent-magnet converter is replaced by an electrodynamic converter, an dc sta-
bilizer is obtained which is just as accurate as the dc version and does not distort
the waveform. Orig. art. has: 2 figures, 9 formulas.
'ASSOCIATION: Kuybyshevskiy politekhnicheskiy institut im. V. V. K~ybysheva 0~uybysl
:Polytechnical Institute)
~SUBMITTED: 04Aug64 ENCL: 01 SUB CODE:
NO REF SOV: 004
MHER: 000
.Card 2/3
L 295.5-6-6 -AP5021435 ENCLOSURE: 01
ACCESSION HR:
R
loa
are
P2
pe reference elemente
Sulator with a weight-tY
schematic diagram of a dC re
fig.
C,,d 3/3
KULIKOVSKIY, L.F.; KARPOV, Ye.M.;POPOVA, G.V.; BRAZHNIKOV, V.A.
Drilling footage recorder. Izv. vys. ucheb. zav.; neft' i gaz. 8
no.091-94 165. (14IRA 1815)
1. Kaybyahevskly politekhnicheskiy institut im. V.V.Xuybysheva.
AP60OZ169-- -----SOURCE CODE: URN 146/65/008/006/00Z5/0032
4-.UTHOR: Korzhavin, 0. A.; Kullkovskly,,L. F.
;.')RG., _KuvbVshev polytechnic I'notitute- (Kuybyahevskiy politekhnicheskiy institut)
ITITLE; Investigation of a niagne tic - amplifier -type permanent-magnet linear-
idisplacement sensor and its errors
1SOURCE: IVUZ. Priborostroyeniye, v. 8, no. 6, 25-32
TOPIC TAGS:
ABSTRACT:
displacement sensor, strain gauge
The results of tests are reported of a new linear-displacement sensor
which combines, in a common magnetic system
the features of an inductive sensor and a
magnetic amplifier. This combination permits
obtaining an output power sufficient for operating,
a recorder. In its initial position, permanent
magnet III overlaps one-half of both O-shaped
cores I and II (see figure, left). Hence, the
-constant fluxes in both cores (due to this magnet),
Magnetic -amplifier -type are equal, and their combined effect on w, and
linear -displacement sensor: w. is zero. When the permanent magnet is
r~agnetic system (left) and displaced, its overlaps change, and an a-c emi
circuit (right)
Card
UDC; _621. 3. 08Z. 7___
El
ACC 14R.
appears across the windings. The sensor is held particularly suitable for applica-
tion where displacement of a few mm are involved. A laboratory model exhibited
!errors of 1,5 and 2. 576 for supply-voltage variations of + 5-1010 and +10-157s,
I respectively. Still better results were obtained with the sensor operated as a voltage
element and when the ferroresonance phenomenon was utilized. The temperature
e rror was 2jo per IOC within - 15 + 55C; it can be considerably reduced by using a
thermistor. Orig. art. has; 4 figures, 5 iormulas, and 1 table.
iSUB CODE: 13, 09 / SUBM DATE: 290ct64 ORIG REF: 008
00, '0i
ACC NR: AP6026948 SOURCE CODE: UR/011,1/66/000/007/0051/0053
AUTHOR: Kulikovskiy, L. F.; Konyukhov, N. Ye.
ORG-. none
TITLS: Multichannel autocompensated multiplication-
and-divisibn device ,cj
SOURCE: Izmeritellnaya tekhnika, n. 7., 1966, 51-53
TOPIG TAGS: calculator, 9" io(l~~r
ABSTRACT- The Kij echnic Institute
developed a contactless logarithmic function
generator (see figure). Fiat logarithmic
winding cd is laid on inoulating plate 1.
Magnet 2 carries field winding ab which
produces a uniform magnetic flux in the
airgap. As the magnet is moved along the
x-axis, an emf proportional to the
logarithm of the coordinate x Is inducec.
in the winding cd. A number of such dev41ces,
suitably conneited in an autocomponsation
circuit, permit multiplying or dividing
ACC NR: AP6026948
any number of input quantities given in the form of displacements or
voltages. Technical data of the above logarithmic function generator
is supplied. Orig. art. has: 3 figures and 10 formulas. [031
SUB CODE3 kr, 09/ SUBM DATE: none/ ORIG REF: 002/ ATD PRESS:5-06.7
L 03013-67 EWT(d)/FWP0) IJP(c)
1'ACC NR; Z 0626701 Ult/0410-/W/000/003/0125/0128-----7
AUTHOR: Karpov, Ye. M. (Kuybyshev); Kulikovs1dy, L. F. (Kuybyshev)
ORG: none
TITLE: The accuracy of the solid angle reading by the receiver of the synchronized servo
system with two degrees of freedom
SOURCE: Avtometriya, no. 3, 1966, 125-128
TOPIC TAGS: angle measurement Instrument, servomechanism system_,,
ABSTRACT: ;Zremote determination Is of special importance during the measurement of
angles of petroletun or gas bore holes during the drilling of well's. F or this purpose, the
authors earlier developed Induction sensors and synchronized servosystems with two degrees
of freedom (L. F. Kulikovskly, Author's certificate No 104141, Byullctenl izobretenly, 1965,
No 9; Ye. M. Karpov, Yu. M. Barkovskiy, Author's certificate No 171038, Byulleten' Izo-
bretenly, 1965, No 10). In this paper they present appropriate theoretical eqmessions giving
the sensitivity of the system. OrIg. art. has: 7 formulas and 2 tables.
SUB CODE: 13,14/ SUBM DATE: 2lJan65/ ORIG REF: 003
UDC: 62--603.53
L 05063-67 3VIT (d
(!)/EWP(V)
ACC NRt monograph UR/_
Kulikovski)r# Longin Frantsevieh, Zarip 14adiyar Fakhritdino Igh
Inductive migration converters with distributed parameters (Induktivn"t
preobrazovateli peremeshcheniy a raspredelennymi parametrami)
(Moscow), Izd-v6 "Energiya," 1966. 111 p. illus., biblio. 8000
copies printed. Series note: Biblioteka po av .tomatike,. vype.156
TOPIC TAGS: inductive converter, inductive displacement converter,
information system
PURPOSE AND COVERAGE: This book is intended for a wide circle of
engineers and technicianalL oncerne with the problems of designiftg
information and measjxrt_~~ t st2ms.~ It may also be used by students
and aspirants of relatea specialties. The book describes inductive
converters with distributed magnetic and electrical parametern. The
theoretical fundamentals of basic converter types are given; cal-
culation methods of theee devices are discussed; and examples of
their use are given. No personalities are mentioned. There are
30 references, all Soviet.
Card 1/4
UDC: 62
L 05o63-67
NRi AM6016003
TABLE OF CONTENTS:
Introduction -- 3
Ch. I. Inductive Converters of Linear Displacements With Distributed
Magnetic Parameters __ 9
1. Basic type of converter with distributed magnetic
parameters -- 9
2. Basic relations for no-load conditions of converter opera-
tion -- 15
3. Converter errors under idling conditions -_ 19
4. Basic relationships for load conditions of converter
operations -_ 21
5. Basic designs of converters with distributed magnetic
parameters -- 25
6. Example of calculation design of displacement converter with
mobile coil and distributed magnetic conductivity -- 27
7. Some examples of the use of converters with distributed mag-
netic parameters -- 30_
Cho II. Converters With-Distributed Magnetic and Electric Parameters
and Mobile Core -- 33"
1. Basic structure of a converter with distributed coil and
Card 2/4
Ai
L 05o63-67
ACC NRs AM6014003
mobile core -33
2. Basic relations for a cq~hvafvter under no-load conditions-- 35
3. Converter operation under foad conditions -_ 44
4. Determining optimal dimensions of a converter with fl-shaped m6qpetia chaft__ 4 8
5. Calculation of a converter -- 53
6. Sources of additional converter errors -- 58
7. Examples of using a converter with distributed coils 66
8. Design of converters with distributed coils and mobile
core -- 71
Ch. III. Inductive Converter With Distributed Magnetic Parameters and
Mobile Core -- 75
1. Basic types of converters with mobile-core -- 75
2. Basic converter characteristics -- 78
3. Converter errors -- 84
4. Calculation of-a converter with a triangular measuring
winding (coil) -- 88
5. Design features of converters with a planar measuring
winding -_ 90
6. Examples of using displacement converters with a planar
measuring winding -- 92
Ch. IV. Displacement Converters With Distributed Electromagnetic
Parameters and Mobile Shield 95
Card 314
Ltd..
7~4
ogo63-67
ACC NR. AM601603
1. Schematic design and basic characteristics of converters 95
2. Converter design -- 99
3. Converter design variants -- 103
4. Fields of mobile-core-converter application 10T
Bibliography -- 111
AVAILABLE Library of Congress
SUB CODEs 09/ SUBM DATEj 16Dec65/ ORIG REFj 030
1 4/4
L o3967-6Z LWT(l)
ACC NR: AP6029785 SOURCE CODE: UR/0119/66/000/00810004/0005
AUTHOR: Konyx~~h~v, N.. Ye. (Engineer); KulikovBkiy, L. F. (Doctor of
31
technical sciences); Shklyair r)
(Enginee
ORG: none
TITLE: Small -displacement transfo rme r -type function generators
SOURCE: Priborostroycniye, no. 8, 1966, 4-5
TOPIC TAGS: function generator, small displacement transducer
.ABSTRACT: The transformer -type flat-wiAing function generator invented In
1963 (Author's Certificate 153190, Bull. izobr. , 1963, no. 4) is briefly described,'
Two rectangular flat measuring windings cd fastened to insulating plate 1 are
connected in series and in opposition. "Condensor" 2 is a magnet carrying two
field windings also connected in series and in opposition. When the magnetic flux,
Card 1/2
LrD G: 621. 3. 082. 74; 6Z L, 3. 083. 6: 531.74
L 08967-67
ACC NR: AP6029785
is equally linked with c and d, the output
ernf is zero. When the "condensor" is
moved along the X-axis, an emf proportional
to the difference of c and d areas appears
at the output. By varying the configurations
of the measuring windings, various functions
can be obtained. A laboratory model of this
function generator exhibited a nonlinearity of
its static characteristic 0. 1% or less and an
error of 15 angular minutes or less. The
error in the output linear function was I%.
C
Orig. art. has: 3 figures and 7 formulas.
0
SUB CODE: 09 SUBM DATE; none /'ORIG REF: 001
ACC NRt AP6033665
_S O-U-R-C-E-C"O'D-E _1WV0'fi97/6_6/600/0 I 0/00i~/OW
AUTHOR: onjukhov, N. Ye. (Engineer);.Kulikqys,~ L. F. (Doctor of technical
JL _ - ~iy, _
sciences); Shklyar, F. M. (Engineer)
ORG: none
TITLE: Multichannel automatically compensated system A
SOURCE: Priborostroyeniye, no. 10, 1966, 25-26
TOPIC TAGS: contactless potentiometer, linear control system, automation equipment
kBSTRACT: A multichannel automatically-compensated system for measuring small linear
lisplacements has been designed, developed, and tested at theiKuybyshev Polztechnical
Enstitute. The system includes a set of transformer-type primary transducers*and
3n EPP-09 multipoint potentiometer. The potentiometer incorporates an LBP linear
-OnL~.'cLless potentiometer to serve as a compensating element. The primary transducer
ias following parametdrs: nonlinearity of static characteristics, not higher than
3.2%; phase error A4, 15-20 angular minutes; sensitivity '0.1 v/mm; and exciting
--urrent, 100 ma. The accuracy of the system is not less than �0.5%. Orig. art# has:
Z figures.
ISUB
CODE: 09/ SUBM DATE: none/ ORIG REF: 002/
/1 UDC: 621.317-39:531.7i621.3.083.5
AC-C API)Oj2169 SOURCE. WDE:
A U -,, 1 OR -KulikovsMy, L. F. (Kuybyshev) Likhttsinder, U. Ya, (Kuybyshev)
Pol'dyayev, G. B. (Kuybysh_c-v)
.ORG: none
.TITLE: An astatic balancing d-~ voltage converter
~,SOURCE: Avtometriya, no. 4, 1966, 127-128
i
T N TAGS:
OPT electric power converter, stationary converter, biprer r(.)PRF,,_Yr
!ABSTRACT: The principles of operation and design characteristics of an astatic
I
.balancing d-c voltage converter in which static errors have been eliminated are
ibriefly described. The basic circuit of the converter incorporates a modulator, a
Ivoltage amplifier, a phase-sensitive rectifier, an integrator consisting of a non-
'linear threshold element and a memory capacitor, and a balancing cathode,repeater with,
!a reduced pl7ate supply. A vibrating contact rectifier server, as the modulator. The !
1volatge a;uplificr, which uses a 6N2P type tube, has a gain of 6400. Balincing voltagal
iis picked off frow, a section of resistors Converted in the cathode circuits of the L
;and L6 tubes and is then applied to the converter input. A special feature of the
~converter is the nonlinear threshold element, which permits rapid charging of the
~capacitor with current pulses of either polarity and very slow discharging. The
.astatic converter has the following technical characteristics: ikiput voltage varia-
',_Carci 1/2 UDC: 621.317.727.2
ACC NR; AP6032169
tions, 0-1, 0-10, 0-100, 0-1000 mv; sensitivity (Uout/Uin) in each rarige 1000,
100, 10, and 1, respectively; basic error, 2.5% in the 0-1 rv range and 0.2% in
:other ranges; response time, 0.01 sec; power supply, 250 v, 50 cps. Orig. art. has:
1 figu:e and 2 formulas.
':SUB CODE: 10/ SUBM DATE: 09Dec65/ ORIG REF: 003/
IL-Card 2/2
KULIKOVSKIY, M.G.; SHISHKIN, L.S.
MOMW
Radio interference areated by high-frequency electrical medical
apparatus and some methods for decreasing it. Ked.prom. 11 no.l:
12-11) Ja 157. (MIaA 10:2)
1. Hoskovskiy gosudaretvannyy soywnyy 2&vod alaktromeditainakoy
appa)*ataz7 OWQ*
(EIRCTRIC APPARATUS AND APPLIANCSS)
(HADIO-INTIMMUCII)
I KULIKOVSKIY. M.G.; SHISHKIN, L.S.
I _~~
Radio interference caused by high-frequency electric medical
apparatus and some measures armed at controlling it. Med. prom.
11 no.2:29-37 F 157 (KIJU 10-4)
(RADIO-_INTJWXRAHCN) (BLECTRIC APPARATUS AND APPLIANGNS)
(KXDICAL INSTRUKENTS AND APPARATUS)
-- I ~ . 0 '1, .
NIKONOV, V.: KtJLIKOIISKIY. P.
"The first Soviet stellar electrophotoneter!~-Photo-~el.ectric photomete~f "
I Astron. Zhur., 16, No 4, 1939. U-15181 23 Cat 1951
KULIKOVSKly. P.G.-
Spatial motions of Mira Ceti long-period variable stars.
Per.zvezd7 6 no.5:225-241 Hr '48. WIRA 12:7)
l.Gosudaretyenn7y astronomichaski7 institut im. Shternberga, Moskva.
(Stars, Variable)
XULIKOVSKIy. P.G.
- -
Xclipsing, linary XV Crgni. Per. zvezdy 6 no-5:286-287 Mr 148.
(MIRA 12;7)
I*Goaudaretvannyy astronomicheekly Inatitut im, Shternbarga, Moskva.
(Stars, varijb1a)
.I P. G.
A manual for an ai,ut~ur u.,troncmev. '.!oskva, Gou. 6
1, hd-vo tck~,:dkc-lecret.
lit ry; 197,,9. 315 -1. CO-27503)
~5~ ~ . 1`18 'Tiu
5
0 K.
111~ro elf,
Aotron. zijjrrvtj i~9 . Mon t 01,
v~,p. 4-, . 249-5.0
SO: UTO---)jS' 35, 1949
9 -t~~'of Sciences May/Jun 4�
-Astrancey
"Plan= of the Astroaamy. Council of the Academy
Of-Sciencea USSR," P. G. Kulikovskly, pp
"Astrca Zbur" Vol 2XVI, no 3
On 18 - 20 Doc 48 an extended plenum of the Aetr
douncil, Acad Sci U&9R, convened in Lenin6rad. It
vas attended by membere of "Astrosoviet"' and
representatives of many USSR astronomy institu-
tl6ne, Academies of Sclances of the,republics,
etc. Among other reports, Prof A. A. Mikhaylov
gave an. accorumt, of ,'roceedings of the Internatl
VSW/Academy of Sciences (Contd) May/Jun 49
'Astr Coaf in Zurich in 1948, activities of Acad
Sel USSR,, and various local activities. A resolu-
ticin vas adopted In vhich the Astr Council vas
called upon to play a leading role in ideological-
.political developments.
58/49TI
rULIKOVSKIT, P.
Second Congress of Astronomers In Poland. Astron.tsir. no.105:14-15 Si 150.
(MLU 6:8)
(Astronomy--Congreases) (Poland--Astronouq)
V A U U J J M-1 Y DLr , U
Stars, Variable
Morpholo ical peculiarities of long--period Cepheids in various star systems. Per.zvezdy
8 no. 1 M51)
9. Monthly LjA& gt Rusgian Accesajong, Library of Congress, August 1952. Unclassified.
KULIKOVSali I,. G.
f
41
and rev. by ~47 G.Per'ag)
Ati-tronamic BtLU. A=d.
go'naoa
Z9" 5s 1951o, 4L-6-413
V*atblY llr-t of Ruvsj~sm Dec. 19310 V~01" 4,0 ED,
M'iw. COPY) 9'p
KULIK6V3KIY, P.
~ztronomy - Poland 29, no. h, 1952
Third session of the Polish Astronomical SocietYp Astrone zhur*
M=thly List of Russian Accessionsjt Library of Congress November 1952 Unelassified
T I "t)"" T'r r.
USSR/Astronomy, Conference Nov/Dee 52
"Eighth Int'ernational Astronomical Meeting,"
P. Kullliovskiy
"Astron Zhur" Vol 29, rio 6, PP 745-760
Describes the International Astronomical Meeting in
Rome, Sep 52, and the trip 9f the Soviet del-egation
from USSR via Prague, Switzerland., Rome, Paples,
and back through Vienna.
239T84
PHASE I TREASURE ISLAND BIBLIOGRAPHICAL REPORT AID 659 - I
BOOK Call 11o.: oB44.K8
Author: KULIKOVSKIY, P. G.
Full TItle: 14-ANDBOOK FW A-LAYMAN ASTRONONER. 2ed., rev. and suppl.
Transliterated Title : Spravochnik astrononua-lyubitelya. 2 izd.
perer. i dopol.
PUBLISHING DATA
Originating Agency: None
Y
Publishing House: State Publishing House of Technical and
Theoretical Literature
Date: 1953 No. pp.: 432 No. of copies: 10,000
Editorial Staff
N. P. Kukarkina prepared star charts, D. Yu. Levin developed
the chapter on meteors, Academician V. G. Fesenkov contributed
latest photoplates obtained with the large Maksutov's meniscus
telescope at Alma-Ata.
PURPOSE: To contribute to t-he process of transforming lay astronomers
into serious scientific workers and to broaden the circle of those
interested in astronomy.
TEXT DATA -
Coverage: The book contains two prefaces to the first and second
editions, an introduction with a chronological table of the develop-
ment,of the science of astronomy from 1100 BC (Chinese) to 1949-1953
1/2
Spravochnik astronoma-lyubitelya. 2 izd. perer. i dopol. AID 659 - I
(discovery of new gaseous hydrogen nebulae), four chapters described
below, an astronomical bibliography (pp. 2go-294), 60 tables (pp.
271-411), 9 supplements with maps, charts and diagrams (pp. 413-423Y,
and an alphabetical index. The chapters are subdivided into many
sections and cover: I, general knowledge of the solar system;
II, mathematical information; III, brief information from general
astronomy; and IV,astronomical observations. The tables include a
variety of astronomical information and data.
No. of References: Several in the text and footnotes and 144 listed
in the bibliography (1920-1953), all Russian.
Facilities: Conference of MOVAGO (Moscow Branch of All Union
Astronomic and Geodesic Society).
2/2
K,ULiK()V,jlr,ll, P. G.
Manual for thc anuteur Lstronomer. izd. 2, perir. i dop. Moskva, Gon. izd-vo
teldinikotecret. lit-ry, 1953. 431 p. maps. (54-3C822)
U/4-KE- 1953
KULIKOVSKIT, P.O.
V 541 Cygni, an eclipsing binary. Per.xvezd7 9 no.3:169-174
Ja '53. MaA 7:7)
1. Gosudarstvannyy astronomichaskiv Inatitut iment P.K.Shtern-
borga.
(Stara, Double)
STr.n KI, Krzysztof [author]; KULIKOVSKIT. P..G. (reviewer).
1A.stronomical instruments.0 (In Polish] Krzyextof Siorkowski. Reviewed by
P.G.Kullk.ovskii. Astron.zhur. 30 no.4*456-457 Jl-Ag 153. (KIRA 6:6)
(Sierkowski, Krzysstof) (Astronomical instruments)
KULIKOVSKIY, P.
-- ighth -, In,ternational Astronomical Congress; addendum. Astron.shur. 30 no.4:
469 Ji-Ag 153. Off-RA 6:8)
(Astronomy--Congresses)
1TULIKOVEY, DOG-.~2192 P. G.
USSR/Astronomy - Conferences, International Sep/Oct 53
"International Astronomical Conferences in 1953," P. G. X1A1V-nvkiY
Astron Zhur, Vol 30, ITO 5, pp 566-_571
A conference was held in Groningen (Holland) end of June, devoted to Problems of
Ealaxies. USSR delegates, headed by Acad Prof V. A. Ambartstuwan, were Prof B. Y.
Kukarkin, Acad 0. A. 1-felnikov, Prof P. P. Parenago, and Docent P. G. Kulikovkiy.
Scientific reports of paxticipants are mentioned with emphasis on Soviet achievements.
After this conference the Soviet delegates spent a few days In Paris for a conference
on astrophysics. They conclude that the lack of decisions at both conferences is iue
to the faulty administration in capitalistic countries.
264T`75
. .........
K(,k I I K ovsl