SCOPE OF WORK

Document Type: 
Collection: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP86-00244R000300360003-2
Release Decision: 
RIFPUB
Original Classification: 
K
Document Page Count: 
4
Document Creation Date: 
November 11, 2016
Document Release Date: 
May 17, 1999
Sequence Number: 
3
Case Number: 
Publication Date: 
September 15, 1970
Content Type: 
REPORT
File: 
AttachmentSize
PDF icon CIA-RDP86-00244R000300360003-2.pdf189.04 KB
Body: 
Approved F~Release 1999/09/27 :CIA-RDR86=002448000300360003-2 September 15, 1970 Mc Lean, Virginia Garage McLean, Virginia GS-O3B-16758~iC?`~"'=~ SG OPE OF WORK. 1. This project- shall consist of, but not be limited to the preparation of drawings, specifications and cost estimates for the design of a new garage and related facilities at the subject site. ?,. All drawings, specifications and cost estimates shall be prepared in accordance with all applicable parts of the GSA Handbooks, design data and criteria contained nerein and shall generally follow the attached agency sketches. 3. Goorcl.ination between GSA and the agency shall be maintained at all times to facilitate timely accomplishment of the design. The site is located on the reservation in the vicinity ~f the Powerhouse and south parking lot, Gate no. 2 and the Scatter,,- Thorne property. The garage shall be constructed of mason~~and shall esthetically compleanent the adjoining structures. The garage shall be approximately 192 feet long by 70 feet wide and shall contain 16, 380 square feet. of net space. The design shall consist of a two story struc- ture with storage on the first Ievel and personnel and administrative offices on the second. ~It shall include parking space for 'six vehicles and b440 square feet for vehicle maintenance. Other features to be included are four standard hydraulir_ lifts, one of which shall ~e heavy duty; car washing equipment, paint and body shop, and atwenty-four hour protection alarm system to be connected to the Headquarters Building central alarm system. Ln additiion, provisions shall be made to install two gasoline pumps with 10, 000 gallon storage tanks, paved vehicle access -circulation area, adjacent parking a~?e,,,for visitor vehicles and parking for 94 additional cars ,protected by overhead canopies . .Approved For Release 1999/09/27 :CIA-RDP86-002448000300360003-2 Approved Fyir Release 1999/09/27 :CIA-RDF~6-002448000300360003-2 STRUCTURAL 1. Provide complete calculations covering all structural aspects of all ~:lterations a:nd new work included in the project. Include, in particular, foundation details, and expected soil bearing pressures due to loading from the four hydraulic lifts, parking areas, and the 10, 000 gallon gasoline storage tanks. (Also describe method of burying gasoline tanks. ) 2. Describe location and anticipated weight of heavy mechanical equip- ment. . 3. Design should be in accordance with: a. GSA Structural- Fngi:neering Handbook dated February 4, 196? b. Building Fire Safety Criteria, GSA Handbook, PBS P 5920.9, dated July 27, 1965. ~ - c. All applicable codes and standards, Where new openings are to be made in existing structure, show analysis of the affected member and show opening framing details. 1:,.. All plumbing arLd heating design work sha11 conform to the require- ments of GSA Handbook, Mechanical and Electrical Engineering, dated April 3, 1967. 2, Provide all required utilities such as water, sewage, gas, etc. Also provide centralized compressed air systems ' ~ -- 3. Fire protection shall be gxovided and shall be in accordance with -the GSA Handbook, Building Fire Safety Criteria. AIRC ONDIT TONING 1. All ventilation and airconditioning_sholl conforzzi to the requirements as specified in Mechanical and Electrical Exi~n.~ui~, a GSA Hand- .~~d. b book, dated April 3, 1967, plus garage~vent~. a ion ;systems shall con- foxrn to requirements as specified in the National Fire Protection Association Standard NFPA 88. Approved For Release 1999/09/27 :CIA-RDP86-002448000300360003-2 :Approved ~r'Release 1999/09/27 :CIA-RDP~8~6-002448000300360003-2 2. -All areas on the second floor are to be airconditioned. The garage foreman's office on the first floor will be airconditioned. All non- airconditioned spaces ,? the rst~floor are to be ventilated.. Fumes ~~tt .. ~ ~ ~ are to be exhaustedfro.m t'~e body shop. An automobile garage exhaust system steal]. be installed in the repair area of the first floox. 3. An airconditioning block load :calculation for peak time of day will be submitted. 4. A psychrometric chart study of the proposed airconditioning system will be submitted. J 5. Drawings shad include location of all major equipment items, method of screening externally Located items from view, duct work, air terminals, automatic temperature control diagrams, flow diagrams, equipment schedules , air quantities , etc . The design shall include the following requirements: 1. , A?480Y/277 s.rolt, 3 phaso, 4 ,=rire ur_dc~rgrourd. feeder for- incoming service and a complete distribution system including panels and branch circuits as required for the new garage. The service shall be obtained from the existing 480Y/277 volt system in the1powerhouse. If the build- ing will utilize electric heating, the feasibility and recommendations shall be made to extend the 41b0 volt system from the powerhouse, 2, Fluorescent lighting within all areas of the building. The lighting fixtures shall be operated at 277 volts. The lighting intensity shall be as recommended in the CSA Handbooks, 3. Suitable lighting for outside parking area, 4. Lighting and power for operation of the gasoline pumps. 5. Fire alarm system as required. ~. Empty conduit system for adequate telephones. Approved For Release 1999/09/27 :CIA-RDP86-002448000300360003-2 Approved F~ert Release 1999/09/27 :CIA-RDP~9~6-002448000300360.003-2 7. A twenty-four hour protection alarm system. It shall be connected to the I-I.~.adquarters Building central alarm. system. All construction within general and hazardous areas shall meet the requirements of the National Electric Code. All existing electrical facilities interfering with new construction shall be relocated as required. Approved For Release 1999/09/27 :CIA-RDP86-002448000300360003-2