(UNTITLED)

Document Type: 
Collection: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP81B00878R001400100004-7
Release Decision: 
RIFPUB
Original Classification: 
K
Document Page Count: 
7
Document Creation Date: 
December 9, 2016
Document Release Date: 
July 20, 2000
Sequence Number: 
4
Case Number: 
Content Type: 
CHART
File: 
AttachmentSize
PDF icon CIA-RDP81B00878R001400100004-7.pdf196.58 KB
Body: 
Approved For Release 2001/07/27 : CIA-RDP81600878R001400100004-7 Z03 VSWR Z02 tz13 Z2 Zoi Zo = I I FIGURE 1 - Coaxial Transmission Line with Choke Couplings Used as a Rotary Joint Approved For Release 2001/07/27 : CIA-RDP81600878R001400100004-7 Approved For Releau,2001/07/27 : CIA-RDP811300878R001411,0100004-7 I 1.5 1.4 1.3 VSWR ?80 1,2 n=0 n=1 n=2 4." _1 1's" t .1-- .1 ?20 0 20 4) IN DEGREES 40 60 80 FIGURE 2 - Input VSWR to Coaxial Transmission Line with Choke Couplings for Various Values of n. Choke Impedance, Z01 = .0324 (Normalized to Unity) Approved For Release 2001/07/27 : CIA-RDP81600878R001400100004-7 Approved For Releauf2001/07/27 : CIA-RDP811300878R001410100004-7 100 _ 30 20 FREQUENCY BANDWIDTH 10 2 1 1 1 1 111111 1 I 1 I 11111 VSW13.1.11 =1 n=1 1 ' .01 .02 J 1 111111 1 1 1 111_1,__1__ .05 0.1 0.2 0.5 1.0 CHOKE IMPEDANCE Z01 ( NORMALIZED TO UNITY) FIGURE 3 - Frequency Bandwidth Curve of Coaxial Transmission Line with Choke Couplings When Chokes are Spaced X/4 at the Center Frequency. Bandwidth Determined by the Transmission Line VSWR of 1.1:1 Approved For Release 2001/07/27 : CIA-RDP81600878R001400100004-7 Approved For Releauk2001/07/27 : CIA-RDP81B00878R001440100004-7 V S W1-R Zoi Z0 20 4- 4- I ? HO 1.08 1.06 1.04 1.02 FREQUENCY BAtZW1DTH, 7. I --x- 2 n= 2 -A I 1 I _1 L __I 1 t...1 LL 1 .01 .02 .05 .1 .2 CHOKE IMPEDANCE Z01 1.0o I I L I t I I I .04 .08 .12 .16 CHOKE IMPEDANCE Z01 (NORMALIZED TO UNITY) FIGURE 4 - Response Curves for Coaxial Transmission Line With Choke Couplings When Chokes are Spaced X/2 Apart at the Center Frequency. (a) Frequency Bandwidth Determined by the Transmission Line VSWR of 1. 1 : 1 . Approved For ReleUgeT21001)blhar :(dAkft1D13840YORROCNNollibetV43- and Limits (a) (b) Approved For Releaue2001/07/27 : CIA-RDP811300878R0011W100004-7 -1.5 .1- t -.--- =0.667X OR n = 2.67 -80 -60 -40 -20 0 O. IN DEGREES 20 40 I I 1 60 80 FIGURE 5 - Input VSWR Curve of Coaxial Transmission Line With Choke Couplings When Chokes are Spaced 0.677X Apart for Zoi = 0.0324 (Normalized to Unity) Approved For Release 2001/07/27 : CIA-RDP81600878R001400100004-7 Approved For Release 2001/07/27 : CIA-RDP81600878R001400100004-7 Xo 2 Z03 Fuzfifw-ir2+z?, z2 z04 Zo ZI zoi V111.11/11/??J/l, Wig/um \Zo2 WM TEFLON DIELECTRIC. F /1 P= X air 4\re? T ? r FIG:Waived 200141101-27`PCIA4ROMP1V13681bPd8114a0 0100 U0 On4i -t 7 Design Using Choke Couplings Approved For Release 2001/07/27 : CIA-RDP81600878R001400100004-7 14.0, FIGURE 7 - DC Isolation Unit Built for 50 mc to 900 mc Operation (Insertion Loss Less Than 0.5 db) Using The Choke Coupling Design Described. (Courtesy of Ramo- Wooldridge Approved For Release 2001/07/27 : CIA-RDP81600878R001400100004-7