DEVELOPMENT OF A LOOP GALVANOMETER AT ZEISS, JENA

Document Type: 
Collection: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP80-00810A002500980006-4
Release Decision: 
RIPPUB
Original Classification: 
S
Document Page Count: 
2
Document Creation Date: 
December 23, 2016
Document Release Date: 
August 5, 2013
Sequence Number: 
6
Case Number: 
Publication Date: 
October 19, 1953
Content Type: 
REPORT
File: 
AttachmentSize
PDF icon CIA-RDP80-00810A002500980006-4.pdf75.18 KB
Body: 
50X1-HUM Declassified in Part- Sanitized Copy Approved forRelease2013/08/05 : CIA-RDP80-00810A002500980006-4 CLA$S1FICATION .16 .T;n1F0T7.:."I'.!:7; INFNITRAL NTEL.I.J.GENCE AnENCY REPORT 44:t.4,1;7 ? ? ?CN F:0 RMAT ? t ,t'W COUNTRY SUBJECT PLACE ACQUIRED DATE Of INFO. East Germany Developmnt of a Loop Galvanometer at Zeiss, Jena z " THIS DOCULIEHT CONTADIS Islt.oRDATWN AFFECTING Yt.2 na.conc.t. Or THE UNITED STATES. LOTHiti me SMARMS OF MAO 30, SECTIODS 70P AND r9h. OF TAC U. 0, COOL. AS ACEBDED. iTS TRAUSLIISSION OE REVEL 1WD Or :TS CONITINTS TO OD Bei:V:1r! Br AR UL0LThOPIZED pErtsss S psims.ns DT LAD TAB FEMODUCTIOU Or /MS MTV Is PROHIBITED ?.17-71r CD NO DATE DISTR. 29 October 1.953 NO. OF FAGS NO OF ENCLS. (LISTED SELOWT SUPPLEMENT TO REPORT NO. THIS IS UNEVALUATED INFORMATION 50X1-HUM 50X1-HUM 1. Development of a loop galvanometer, which was begun in the spring of . 1953 in the Construction and Experimental Department (Konstruktions-und Versuchsabteilung)(KoV) of VEB Carl Zeiss, Jena, was successfully completed in August 1953. Two models .are finished. The in was developed on the basis of preparatory research carried out by former Zeiss scientist rschau (fnu), who died in 1945. Froduction of the device will begin in 1954. 2. The device consists of a container for the optics and a magnet case which can be revolved around a horizontal axis. The magnet case con- tains the loop holders which can be replaced, and two permanent mag- nets, The following are the technical data en the device: Interior resistance - about 7,5 ohms Sensitivity - from two times ten power minus seven to five times ten power minus seven amperes per scale part (A/Skt). The highest sensitivity is ob- tained when the loop is in a vertical position. 3. Because of its small interior resistance and great sensitivity, the de- vice can measure very weak thermecurrents, CLASSIFICATION SECI7.7. X ! NAVY f4SR3 I DISTRIBUTION L-1-TT-777 [FATE ARMY xi AIR FSI U _LL 50X1-HUM Declassified in Part - Sanitized Copy Approved for Release 2013/08/05: CIA-RDP80-00810A002500980006-4 Declassified in Part - Sanitized Copy Approved for Release 2013/08/05: CIA-RDP80-00810A002500980006-4 50X1-HUM Declassified in Part - Sanitized Copy Approved for Release 2013/08/05: CIA-RDP80-00810A002500980006-4