Approved For Release 2006/07/07: CIA-RDP78BO5171AO00400030097-4 TSSG/ESD/TEB-08-70 8 May 1970 MEMORANDUM FOR: Chief, Research & Engineering Division, TSSG THROUGH Chief, TEB/ESD Chief, ESD/TSSG SUBJECT : Memorandum Test Report on N.B.S. Measured Color Properties of Light Tables and Through a Microstereoscope 1. In late October 1969, ESD/TEB started an investigation 'to determine what equipments and methods were available for testing and evaluating the color quality and color rendering properties of fluorescent luminaries as used with viewing light tables. This investigation resulted in procurement of equipment and determining test procedures, both of which are now in use by TEB. The measuring system adopted was the CIE method, a widely used psychophysical system. 2. The above in ion led to discussions with of the Photometry Section, Optical Physics Division, National Bureau of Standards. This division has been making color measurements in the past. To establish a better "feel" for color measurement and to provide base line data which we could compare our measuring techniques to, TEB asked N.B.S. to make selected color measure- ments of luminaires in tw ight Tables and through a microscope system.- This data could also provide the center with a start point for specifying color by describing the color characteristics of existing equipments. On November 26, the following equipments along with a list of required measurements were delivered to N.B.S. 1) ight Table Model MIM-47B100, 2) i ht Table Model MIM-455100 3) L 1 Model Zoom 2 wi a omboid 2X attachment. 3. Although the spectroradiometric measurements were made and the equipment returned to NPIC in December, the data requested has been long in coming. An official report will be provided by N.B.S.at a later time. The measurement data which will be in the formal report has been obtained and is given in detail below. CONFIDENTIA ~nnFrn7m7 A. fnP7sRQ517lA000400030097-4 25X1 25X1 Approved For Release 2006/07/07 7CIA-RDP78B05171AO00400030097-4 Po,:,ition of Sensor During Measurement Left ' Luminaire Right Light Table Serial No. 00037 Correlated Color Temp. - Kelvins Position of Sensor 1 2 3 4 5 6 At maximum intensity 560 0 5600 5450 5650 5650 5650 At 10% of maximum 550 0 5450 5400 5500 5550 5550 Chromaticity Coordinates At maximum intensity x - .33 0 .331 .334 .330 .329 .329 y .35 8 .359 .362 .357 .357 .357 At 10% of maximum x - .33 3 .334 .336 .333 .331 .332 y - .36 1 .362 .364 .362 .361 .360 Color Rendering Index At maximum intensity 73. 11 73.8 73.3 73.6 73.7 73.2 At 10% of maximum 75. 3 75.4 75.1 75.3 75.1 75.1 C01'IFIDENTIA Approved For Release 20061 f r-)CIA-RDP78BO5171 A000400030097-4 Light Table Serial No. 00195 Correlated Color Temp. - Kelvins Position of Sensor 1 2 3 4 5 6. At maximum intensity 5750 5700 5750 5650 5550 5550 At 10% of maximum 5600 5450 5450 5650 5600 5400 Chromaticity Coordinates At maximum intensity x.- .326 .328 .326 .329 .331 .331 y - .364 .366 .365 .364 .367 .366 At 10% of maximum x - .330 .334 ?334 .330 .330 .336 y .364 .367 .369 .364 .365 .370 Color Rendering Index At maximum intensity 75:7 76.3 75.5 75.7 75.5 75.9 At 10% of maximum 77.7 77.5 77.1 77.4 77.4 78.0 Table 00195 Light Source When Viewed Thru Microscope and Rhomboid Optics Correlated Color Temp. - Kelvins At maximum intensity - maximum magnification - minimum magnification Chromaticity Coordinates At maximum intensity - maximum magnification x 1 y - minimum magnification x I y Color Rendering Index I At maximum intensity - maximum magnification - minimum magnification Rhomboids Over Position 2 Left Eyepiece Right Eyepiece 4800 4800 4800 4800 .363 .360 .443 .443 .364 .362 .443 .443 56.9 57.0 57.0 56.8 CONFIDEKIRDP78B05171 e 2nnAm7m7 A0 00400030097-4 Approved For Release.2006/07/``0lpg~7 : CIA-RDP78B05171AO00400030097-4 4. On 21 April, TEB made color measurements on the luminaires in light table serial no. 00037. The data yields a relative comparison of the accuracy of TEB's measuring process at that time to data supplied by N.B.S. During the 4 month intervening period between these measurements, `it is believed that the light sources received only short periods of use. TEB's measurements are listed below with. percentage deviation from N.B.S.- data. This assumes that the color quality of the luminaires did not change due to intervening use. Light Table Serial No. 00037 (TEB Measurements) Correlated Color Temp. - Kelvins Sensor Position 2 Deviation Sensor Deviation from Position from NBS Data 5 NBS Data At maximum intensity 5550 0.9% 5600 At 10 fo of maximum 5200 - 4.6% 5150 1 - 7. 2% Chromaticity Coordinates At maximum intensity x - .331 o . o~ .331 + 0. 6%0 y - .357 - 0.6% .357 0. 0% At 10% of maximum x - .341 + 2.1% .343 + 3. 6% y - .363 + 0.3% .366 1. 4% Color Tendering Index At, maximum intensity 69.1 - 6.4% 69.1 - 6. 2% At l0% of maximum 70.3 - 6.8% 70.9 - 5.6 % est Engineer TEB/ESD 2ClflEiiIfl ~?NF!D N~'t*r* l .RDP78BO Approved For Release 2006/07107: CIA-RDP78B05171A000400030097-4 Distribution: Orig. & 2 - NPIC~`1'SSG~ESD~TEB 1 - Addressee 1 - NPIC~TSSG~PPS ' 1 - NPIC~TSSG~RED ` 1 - NPIC~TSSG~IZLD l - NPTC~TSSG~RED 1 - NPTC~TSSG~RED 1 - NPiC~TSSG~RED NPIC~TSSG~ESD (through Ch~TSSG~ CONFIDE~T1~~, 8 May 1970 Approved For Release 2006/07107 :CIA-RDP78B05171A000400030 CENTER~UTING SLIP TSSG~TEB~ESD I 11 May 70 CH/TSSG ESD Chief RED