TRIP TO(Sanitized) 1540 LIGHT TABLE PROTOTYPE PROJECT

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B05171A000400030096-5
Release Decision: 
RIPPUB
Original Classification: 
C
Document Page Count: 
10
Document Creation Date: 
December 28, 2016
Document Release Date: 
June 7, 2005
Sequence Number: 
96
Case Number: 
Publication Date: 
June 19, 1970
Content Type: 
MFR
File: 
AttachmentSize
PDF icon CIA-RDP78B05171A000400030096-5.pdf392.94 KB
Body: 
Approved For0ease 2005/06/23: CIA-RDP78B0517000400030096-5 CONFIDEPT'TIAL TSSG/ESD/TEB-16--70 19 June 1970 MEMORANDUM FOR THE RECORD I-LLEGI-13 SUBJECT: Trip to 11540 Light 25X1 Table Prototype Project 1. On 8 June 1970,1 RED/TSSG and I visited 0 XI Ito inspect the engineering modifications which were made on the prototype 1540 Light Table. 5X1 representatives contacted were: Washington area representative. Upon inspection of the equipment, it was found that all discrepan- cies which were noted as a result of T&E and operational evaluation were not corrected. However, the two major problems, the gross focus and Y motion fail safe, which had caused the equipment to be unacceptable had been redesigned. The equipment, as presently configured, is shown in the attached photographs. GROSS FOCUS CONTROL The microstereoscope pod Z motion mechanism which is used to provide gross adjustment of the optics for the different focus ranges of the various microstereoscope., is now completely reconfigured. This device uses a chain and sprocket method to raise and lower the pod holder. In addition, a slip clutch is employed so that the optics cannot be driven into the light table surface and damaged. A hand crank is provided to change the gross focus adjustment. This control must be rotated 3 turns to provide 1 inch of A'Z motion. The pod holder may also be manually raised by lifting, as this motion overcomes the slip clutch. The design of the Zmotion control appears sound from a technical standpoint. Y MOTION FAIL-SAFE An acceptable fail safe for the Y carriage motion has been incorporated. An electro-mechanical clutch, which locks up the.Y carriage, is energized by a mercury switch when the table is tilted 2 or 3 degrees. This action can be defeated only after an aircraft type "arming" toggle switch is energized, and an illuminated push button, located on a panel at the right of the pod holder, is depressed. (See photos) CARRIAGE MOTIONS The Y carriage motion has been improved. The original drive motor has been replaced by a motor of greater capacity. The carriage motion p ~/~~ DWclpss R~[iev b NG rove or a ease 6/23~~~, 1UP78B05171A000400030096-5 l~ -1 ENDIAL GRUU t --_ Czclcdcd tro au!;, - .1511. doxnerad;c; and Approved For ease 2005/06/23: CIA-RDP78BO517 W00400030096-5 CO1,IFlDI N''TlA's._ and speed controls have been relocated on a panel at the right of, and adjacent to the pod holder. The controls are convenient and easy to use. Carriage Speeds: A. Minimum usable Full Tilted + 15 secs./in., -Y 1.5 sec./in. +3 7 secs./in. B. Maximum usable Full Tilted +Y 1.8 sec./in., -Y_ 1.5 sec./in. +) .8 sec./in. +Ya 14 secs./in. + 7 secs./in. Not Tilted +Y 1.7 sec./in. .8 sec./in. The carriage rate control requires almost constant adjustment when scanning imagery because the X motion runs at about double the speed of the Y motion. MISCELLANEOUS CHANGES (See accompanying photographs) The table elevation and tilt control box has been relocated. 'The two mechanical shade controls have been removed. The location of the film drive motor controls have been switched with that of the illumination controls. The film drive speed controls have been replaced by larger round knobs. The right inboard roller hinge has been redesigned so that the load- ing port can be manually opened. 2. On 9 June 1970 we were joined at I land 1of IEG, andi of DIAAP-9. These individuals examined the equipment from an operational standpoint. The equipment modifications were found to be generally acceptable. However, it was felt that the two "Gross" focusing knobs should be made more massive. In addition it was felt that the X carriage motion needed the same type of electrical locking action presently used on the Y motion fail safe, whenever the carriage drive motors are de-energized. 3. Discussions were held with 0 representatives in order to determine which additional specific fixes and modifications would be incorporated into the,production model of the light table. F representatives comments were as follows. - 2 - Approved For Release 2005/06/23 : CIA-RDP78BO5171A000400030096-5 CONFIDENTIAL 25X1 25X1 25X1 25X1 Approved For ease 2005/06/23: CIA-RDP78BO517000400030096-5 C0NH1DLt%!TI \L FILM HANDLI.TIG Plan to use a "T" bar arrangement with the brackets so that drive motors will slide more easily. The exposed electrical motor wires will be redressed and tied down to the table. The quick releases for film spool bracket will be relo- cated downward approximately 450 from the horizontal and will utilize a straight lever arrangement (a previously used configuration). Emergency film hand cranks will be provided. Rollers will be placed on the light box cover so that the cover can be used for split-v? viewing. MICROSTEREOSCOPE MOUNT AND CARRIAGE Some means will be provided, either to give an adjustable drag to the X motion,.or to lock the carriage in X when the X motor control is released. The X carriage speed will be reduced to match that of the_Y carriage when the table is operated in the horizontal position. A pod holder of design will probably be incorporated in lieu of the lI fine focus moue . MISCELLANEOUS CHANGES The sharp edges of the film drive and light control boxes will be contoured. A~raised 2 inch lip will be placed on the rear back edge of the tables back panel. Larger, easily lockable swivel casters will be used. A film threading diagram will be displayed on the raised back panel. Pictograms will be placed at the motor transport stations to show correct switch positions for the different film threading configurations. The table elevation and tilt control box will be re-relocated. It 25X1 will be moved forward slightly and mounted lengthwise. Test Engineer TEB/ESD Approved For Release 20051,8~~,q~jfj1EB05171A000400030096-5 Approved For ase 2005/06/23: CIA-RDP78BO517 0400030096-5 G01i ti it Di t1:'?]Lution : Original - TE;SG `.C]?l3 1 - 1 1I' 9 1 - RE1)/'TSSG 1 - Chief , ESll NPIC/TSSG/ES])/TEI) (19 dune 70) Approved For Release 2005% 6/2 : C1i4D8`B05171A000400030096-5 Figure 1 Approved For Release 2005/06/23: CIA-RDP78BO5171A00040003 96-5 .YICROSTEREOSCOPE "GROSS" Focusing Mechanism Approved For' Release 2005/06/23 : CIA-RDP78BO5171A000400030096-5 Approved ? Release 2005/06/23: CIA- 78BOO1-41A000400030096- 1 iec CC ~3'O S . Figure 4 Fail-safe override toggle switch. Approved For Release 2005/06/23 : CIA-RDP78B05171A000400030096-5 Approved For lease 2005/06/23 CIA-RDP7813051700400030096-5 Figure 5 Inboard Roller - Open Figure 6 Inboard Roller - Closed Approved For Release 2005/06/23 CIA-RDP78B0517.1A000400030096-5 Approved For ease 2005/06/23: CIA-RDP78B0517W00400030096-5 Figure 7 Table Elevation and Tilt Control Box. Figure 8 Motor Drive and Illumination Control Pane[ Approved For Release 2005/06/23 : CIA-RDP78BO5171A000400030096-5 Approved For Release 2005/06/23 : CIA-RDP78BO5171A000400030096-5 BEST COPY A VAILABLE Approved For Release 2005/06/23 : CIA-RDP78BO5171A000400030096-5 25X1 Approved For Release 2005/06/23 : CIA-RDP78BO5171A000400030096-5 Approved For Release 2005/06/23 : CIA-RDP78BO5171A000400030096-5