DIGITAL READOUT COUNTER

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B04770A002900020067-7
Release Decision: 
RIPPUB
Original Classification: 
K
Document Page Count: 
3
Document Creation Date: 
December 28, 2016
Document Release Date: 
August 30, 2005
Sequence Number: 
67
Case Number: 
Publication Date: 
July 10, 1964
Content Type: 
REPORT
File: 
AttachmentSize
PDF icon CIA-RDP78B04770A002900020067-7.pdf136.74 KB
Body: 
STAT Approved For.ease 2005/11/. July 10, 1964 DIGITAL READOUT COUNTER STAT and has started work. The schedule is as follows: STAT 0 has received the contracts for the new counter systems 0 0 STAT STAT STAT STAT One 4-axis system Three 2-axis systems Spares for previous two 2-axis systems RECEIVED CONTRACT SCHEDULED COMPLETION 6/2/64 10/1/64 5/20/64 l on 8/15/64 1 on 8/30/64 1 on 9/15/64 6/10/64 8/15/64 The three 2-axis systems will be identical to the previous 2-axis system for the reading head. On both the 2-axis systems already delivered, there has been some mismatch with respect to 0 input impedance. has been requested to change their input amplifier board, w ich they did, and supplied new boards. STAT STAT STAT On the new counters now in work would like to avoid any STAT input impedance mismatch. has discussed this STAT in detail with telephone and has received verbal direction from o n. however, would like written clarification of the input impedance requirements. He needs this no later than 1 August 1964. The clarification II STAT wants is: 1. Define the input pulse (which is the pulse that defines a count). This is the pulse from the sensor to the F---] input amplifier. a. Min/max voltage level for a 0. Declass Review by NGA. Approved For Release 2005/11/21: CIA-RDP78BO477OA002900020067-7 Approved For ease 2005/11/21: CIA-RDP78BO477OP02900020067-7 STAT Digital Readout Counter b. Min/max voltage level for a 1. c. Pulse fall time and pulse rise time. d. would prefer to have a pulse sketch which is unambiguous. Such as: 2. Sensor source impedance. 3. Is any accessory power to be provided to the sensor TAT 4. 5. a the positive Interconn count trigger on the negative going or going edge of the pulse? ecting cable length required for. each system. TAT is holding off on the cables till the latter part of the manufacturing cycle, but he must start them by 1 August. If he doesn't hear by then, he plans to proceed on the basis of furnishing 10 ft long cables. STAT beneficial if could schedule a visit touring the STAT week of 10-14 st, or immediately thereafter. STAT finally rec eived cost information from his accounting spar went on the previous two 2-axis systems already delivered. Their cost, th roug h G&A but not including fee was STAT When compared to a contract sales price of it shows STAT TAT a sizable loss . W hen heard that0 lost money on the STAT job, he reques ted advise him how much. 0 has not STAT yet made any f orma l overtures regarding the loss. In fact, they have not deci ded whether or not they should. Testing of the first 2-axis system is scheduled for the period of August 3 to August 14. I believe it would be Approved For Release 2005/11/21: CIA-RDP78BO477OA002900020067-7 Approved For ease 2005/11/21 CIA-RDP78B0477002900020067-7 BTAT Digital Readout Counter At request of I advisedi of maintenance was scheduling a visit o on Ju:Ly to discuss counter electronics with said that would be O.K. but he did not now vacation schedule. If there is a conflict, wi 11 advise us. TAT ndicated he knew about the problem with the new input amplifier card he had sent to He said it could be easily corrected b a us i.n a ias. He has instructed and authroized to correct the bias which should eliminate the trou e. Approved For Release 2005/11/21: CIA-RDP78B04770A002900020067-7 STAT STAT STAT STAT STAT STAT STAT