HARD COPY FROM TV DISPLAY

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B04770A002700040027-1
Release Decision: 
RIPPUB
Original Classification: 
K
Document Page Count: 
7
Document Creation Date: 
December 28, 2016
Document Release Date: 
June 16, 2005
Sequence Number: 
27
Case Number: 
Publication Date: 
October 26, 1965
Content Type: 
LETTER
File: 
AttachmentSize
PDF icon CIA-RDP78B04770A002700040027-1.pdf259.93 KB
Body: 
Approved For Release 2005/06/23 : CIA-RDP78B047704A042700040027-1 26 October 1965 Attention Subject: Hard Copy from TV Display based upon its extensive experience in high quality TV recording, high resolution film scanning, processing and recording, proposes the following system for use in individual frame recording of a TV signal. The proposed system as shown in Figure 1 is the minimum complement of equipments required to achieve the desired results. This system can be expanded, as an option, to display and record TV signals based upon techniques other than the U. S. Standard, which are: 525 lines per frame 30 frame, 60 fields, 2:1 interlace 15,750 scan lines/second 4 me/s video bandwidth As an additional option the film output of the proposed system can also be fed, for roll film use, directly into a rapid film processor which will provide a dry positive transparency of the data displayed within approximately thirty seconds of the time of exposure on the film. The exact time will depend on the distance between film exposure and output of processor and the speed with which it is desired to move the film, assuming unexposed film between exposures is expendable. As shownin Figure 1, a 17" monitor is viewed. The observer actuates the camera focused onto the high resolution flat face recording monitor, and the display is recorded on Blue Sensitive Hyscan or similar film. The camera can use roll film, cut film, film pack, and Polaroid film, both cut and roll. The picture format on film will be 2-1/1+" x 3". The system, as shown, will take the pictures at an exposure of 1/30 second. If the tape playback machine is capable of repeating one frame over and over, the camera exposure time can be adjusted accordingly. Declass Review by NGA. Approved For Release 2005/06/23 : CIA-RDP78BO477OA002700040027-1 Approved FI,se 2005/06/23 : CIA-RDP78B04770,A0000040027-1 -2- 26 October 1965 I igh Resolution CRT used in the recording monitor will conform to the specifications given on the attached Technical Bulletin No. CL-1180. The system, as schematically pictured in Figure 1, can be furnished at a fixed price cost of assuming the availability of a_GFE tape play- biine providing a composite video signal. System delivery will be four months after award of contract. Very truly yours, Manager, Program Development Intelligence Systems Department /ces Attachments Approved For Release 2005/06/23 : CIA-RDP78BO477OA002700040027-1 STAT Approved For Release 2005/0 12 CIALRD'78R04770AO02f018 TYPE CL-1180 CATHODE RAY TUBE typ" CL-1180 i a sink Ic beam, magnetic deflection and focus ci f iode rav tube of high resolution e specially deE t,ned for flying spot scanner appl rations. The tube (s mounted in an assembly w th the deflec i uu yoke, focus coil, magnetic shield and suppor mousing. -l he tube features an efficient: electron t u"1 which can be modulated with sn all changes r resole tion, a fine grain. P16 phosohor screen rhi.ch has been optimized for low fix( 1 noise and imaximum brightness, and a high performance defl? "ion arid focus system which is ali} ned and fix( c' requir ing a minimum of operrting and it=,'allation adjustments. ELECTRICAL Deflection yoke Resistance, each winding (half axis) Inductance, each winding (half axis) Focus coil Resistance Inductance OPTICAL Phosphor P16 Fluorescence Violet Persistence Extremely short Faceplate Clear, non-browning, flat within 0.003 in. MECHANICAL Overall length 20% in. nom Overall diameter (including flange) 7 in. nom Minimum useful screen diameter 4.25 in. * To meet customer requirements STAT STAT Approved For Release 2005/06/23 : CIA-RDP78BO477OA002700040027-1 Approved For,R.Release 2005/06/23 : CIA-RDP78BO477070A~700040027-1 Heater voltage b.3_+_10% Vac Accelerator (anode) voltage 30,000 Vdc Accelerator (anode) current, peak 20 pa Grid No. 1 voltage Positive -0 Vdc Negative -150 Vdc Heater to cathode voltage, peak 180 vdc Deflection coil input voltage, peak 500 vac Grid No. 1 resistance 1.5 Meg Q Electrode capacitance Grid No. 1 to all other electrodes 50 pf Cathode to all other electrodes 50 pf Anode to all other electrodes 500 pf min. Heater voltage (note 1) Heater current Accelerator voltage (note 2) Grid No. 2 voltage Grid No. 1 voltage for cut-off (note 3) Grid No. 1 modulation voltage (note 4) Light output (note 4) Light output uniformity Shading (note 5) Noise (note 5) Resolution (notes 4 and 6) Focus coil excitation Deflection coil current for spot centering (each axis) Deflection factor Spot size (sigma value) Deflection axis alignment Deflection defocusing * Depends on coil 6.3 Vac 0.45?10% Aac 25,000 Vdc 1000 Vdc -60 to -20 Vdc 15 Vac max. 0.4 ItW/cm" 10 % max. 2 % rms max See chart - Resolution characteristic 700 amp-turns mAdc max. A/in. ..0008 inches max t_ 1 degree 1.8:1 max. Approved For Release 2005/06/23 : CIA-RDP78BO477OA002700040027-1 Approved For Release 2005/06/23 : CIA-RDP78BO477OA002700040027-1 118 11) CONNFCIOR -! (fl I I (Fl \\ NOTES: Values given are nominal unless otherwise indicated. 1. It is preferable not to operate the heater negative with respect to the cathode for long periods of time under severe environment con- ditions. 5. Measured by scanning the phosp wcr with a spot of the minimum resolution cha acteristic and observing the light output witF in S-11 response photomultiplier. Not mor( an 15 2. External conductive coating connected to Eb supply return. 3. Visual extinction of focused, undeflected spot. 4. Beam current of 10 IiA (Cathode current less leakage). noise pulses of 50% amelitude will oc :!ut in the useful screen area. 6. As measured by the sr annertechni 1;.w using a square wave transmission test obj~ ct whose half period is the statei fraction of the scan length. The modulation esulting fron the tube spot size will be a given percentat,e of the "black" to "white" ampl tude. Approved For Release 2005/06/23 : CIA-RDP78BO477OA002700040027-1 Approved For Release 2005/06/23 : CIA-RDP78BO477OA002700040027-1 20% I 1/4 DIA.-- 8 HOLES - EQUAL I_Y SPACED 6%2 IN. DIAMETER BOLT CIR(LE STAT 60 50 40 500 1000 2000 RESOLUTION (TV ELEMENTS/SCAN) WHITE A } BLACK MODULATION (%) =A x 1O[1% Approved For Release 2005/06/23 : CIA-RDP78BO477OA002700040027-1 Approved For Release 2005/06/23 : CIA-RDP78B04770A002700040027-1 GFE MAGNETIC TAPE PLAYBACK composite video signal 5" RECORDING MONITOR 17 " VIEWING MONITOR CAMERA ACTUATOR RECORDING CAMERA FIGURE I. PROPOSED SYSTEM BLOCK DIAGRAM Approved For Release 2005/06/23 : CIA-RDP78B04770A002700040027-1