REQUEST FOR APPROVAL OF ACUITY ADAPTERS FOR(Sanitized) EYEPIECES PROJECT WITH (Sanitized) FROM FY-1967 FUNDI
Document Type:
Collection:
Document Number (FOIA) /ESDN (CREST):
CIA-RDP78B04770A002000060003-2
Release Decision:
RIPPUB
Original Classification:
S
Document Page Count:
8
Document Creation Date:
December 28, 2016
Document Release Date:
December 4, 2002
Sequence Number:
3
Case Number:
Publication Date:
March 1, 1967
Content Type:
MF
File:
Attachment | Size |
---|---|
CIA-RDP78B04770A002000060003-2.pdf | 347.7 KB |
Body:
Declass Review
by NIMA/DOD
FROM
T D S
DATE
1 March 67
TO
INITIALS
DATE
DIR
DEP/DIR
EXEC/DIR
TECH ADV
SPECIAL ASST
CH/SS/MSS/B&
B X
1
ASST FOR P&M
ASST FOR OPS
ASST FOR PA
ASST FOR TD
CH/CSD
CH/I PD
CH/PD
CH/PSD
CH/TID
CH/CIA/IAD
CH/DIA/XX-4
CH/DIA/AP-I P
CH/SPAD
LO/CGS/CIA
Ole
8 : CIA-RDP78B04770A002000060003-
IP FM 30 (10-66) DESTROY PREVIOUS
EDITIONS
CENTER R01'T,N
yed Por Release 2003/01/28: C RRPSI904770A002000060003-2
ILLEGIB
CENTER ROIG SLIP
A?PsevedFer Release
T D S 11 March 67
TECH ADV
SPECIAL ASST
CH/SS/ISSy'B
ASST FO P&M
ASST FOR PA
I
CH/CSDI
LO/CG$
L0/NSA
IP FM 30 (110-66) DESTROY PREVIOUS
EDITIONS
,
04770A002000060003-2
Approved For Release 2003/01/28 : CIA-RDP78BO477OA002000060003-2
Approved For Release 2003/01~;IP78B04770A002000060003-2
NPIC/ S/D--7l6-
1 k reb 1967
BANDUM POR; Director, National Photographic Interpretation Center
THROUGH : Chief, Support Staff
SUBJECT
from 1PY- 1967 rMcung
Chief, Administrative Staff, O/DbI memorandum of 4
Request for Approval of Acuity Adapters fan yepic cea 25X1
Project c .t~ 25X1
ary 19$ on "Approval of R&D Activities .
1. The Acuity Adapters forlyepieces Project has been prepared
for your approval in order for contract negotiations to be carried out in
YY-1967. This project calls for the development of five sets of optialmic
corrective devices in a three-month effort.
2. The attached staff study, tab, and contract propose.l preset
tinent information and justification for this project.
3. It is recommended that this project be approved a
level of F-----lin rY-?-196'x.
Director
National Photographic Interpretation Center
Distribution:
Orig NPIC/SS/LB (After Approval)
1 - Ch,SS/NPIC
w/l - Ch, B&FB/MSS/NPIC
1 LB/SS/NPIC
1 - O/A/TD
App oveSd For Release 2003/01/28 : CIA-RDP78B04770A002000060003 2j aa
SECRET eoinradin and
h@:,f~SS1;iCBffafl
lALTI&
Approved. For Re RDP78B04770A002000060003-2
23 February 1967
0
To develop a device which will permit a photo interpreter to set
his own opthalmic correction on a stereoscope eyepiece, thereby opti-
cally optimizing the microscope for his personal use and making it un-
necessary for him to wear glasses while looking through the instrument.
In August of 1964 the Imagery Analysis Staff received a recommenda-
tion from of the Optics Panel Scientific Advisory
Board, that an op a ?c correction device be developed and tested for
use by photo interpreters. He believes that interpreters using this
device would not only see better but would experience considerably less
eye fatigue than if they were to wear their own glasses as they now do.
Following this recommendation CIA/IAS requested that the Technical De-
velopment Staff investigate the -possibility of providing the type of
adapters suggested byF -1
a. Current Procedures., Photo interpreters who require opthalmic
corrective devices must wear eyeglasses when using a microstereoscope.
b. Origin of Concept. This concept of individual adjustable eye-
pieces containing integral o thalmic corrective prescriptions, origi-
nally suggested by in his capacity as a member of the Optics
Panel Scientific Advisory Board, is based on theoretical and empirical
findings that eyestrain and fatigue are materially lessened when opti-
mum optical aids are employed by individuals doing visually exacting tasks
such as those involved in the photointerpretation process.
c. Proposed Program. The proposed program will provide five sep-
arate matched sets of acuity adapters, each uniquely designed for an
individual within the photo interpretation group. The initial five
photointerpreters were selected to provide a test sample and will rep-
resent a cross section of the visual anomalies found among a represent-
Approved For Release 264J 14$604770A002000060003-2
1/28: CIA-RDP78BO477OA002000060003-2
ApproRON
NFATW
ative group of individuals, e.g. astigmatism and myopia. These five
sets are to be tested operationally to prove the feasibility of the
concept.
d. Selection of the contractor. This contract is to be awarded
on a sole source basis because it is too small to solicit on a broad
participation basis. has been selected on the premise
that the acuity adapters are to be designed for a viewing instru-
ment and on the acknowledged technical competence of the firm itself.
Should the initial five sets serve to prove hypothesis,
competitive bids will be solicited to procure a .arger quantity.
e. Contract Period. The acuity adapters are estimated to be de-
liverable within two or three months from initiation of the contract.
f. Coordination. Internal and external coordination has been
part of the project since its inception. The appropriate technical
personnel of PAG, CIA/IAS and TID have been briefed on this project.
This project has been coordinated with DDS&T/ORD and presented to the
Committee on Photographic Exploitation and representatives of Army,
Navy and Air Force.
g. Alternative. There are two obvious alternatives to the de-
velopment of acuity adapters:
1. Use of contact lenses.
2. Continuation of present procedures.
The use of contact lenses poses a problem of inducing the photo
interpreter to accept them. Indications are that many photo in-
terpreters would probably not accept the use of contact lenses as
readily as acuity adapters, and they cannot legally be forced to
use them. The expense of contact lenses would probably be about
equal to acuity adapters. As explained. above, the second alterna-
tive is unacceptable.
ended that approval to contract with C
f FY-67 funds for a three-month effort.
6. REFERENCE AND ATTACHMEN'T'S :
Tab A. Catalog Form
Tab B. Development Objectives
Attachment: Proposal
25X1
25X1
25X1
Approved For Release 01/28 : CIA-RDP78BO477OA002000060003-2
IFIDENT1AL?
25X1.
25X1
25X1
25X1
R & 0 CATALOG FORM
DA10 February 1967
I. PROJECT TITLE/CODE NAME
2. SHORT PROJECT DESCRIPTION The fabrication of acuity
adapters for microscope eyepieces so that each
Acuity Adapters for=
interpreter may have his own, unique, opthalmic
Eyepieces
correction.
3
R
r
5. CLASS OF CONTRACTOR
6. TYPE OF CONTRACT
Manufacturer
Fixed Price
7. FUNDS
S. REQUISITION NO.
9. BUDGET PROJECT NO.
FY 19 $ None
NP-V-12-02127
10. EFFECTIVE CONTRACT DATE
II. SECURITY CLASS.
FY 19
(Begin - end)
March - Ma
1967
AA-Confidential
y
T-Unclassified
FY 19 $ None
W-Unclassified
_
12. RESPONSIBLE DIRECTORATE/
_
ICER TELEPHONE EXTENSION
DDI/NPIC/TDS
13. REQUIREMENT/AUTHORITY Both medical and psychophysical experts have deemed this
method superior to glasses and contact lenses for refractive correction during
photo interpretation.
14. TYPE OF WORK TO BE DONE
Engineering Development
15. CATEGORIES OF EFFORT
MAJOR CATEGORY
SUB CATEGORIES
Viewing Systems
Lenses
_
Microsco es
16. END ITEM OR SERVICES FROM THIS CONTRACT/IMPROVEMENT OVER CURRENT SYSTEM. EQUIPMENT, ETC.
Five separate prototype adapter sets, cases and instructions.
17. SUPPORTING OR RELATED CONTRACTS (Agency & Other)/COORDINATION There is no known equipment
available or under development which will satisfy this requirement. This pro-
'ject has been coordinated with: DDS&T/ORD, and presented to the committee on
Photographic Exploitation and representatives of the Army, Navy and Air Force.
18. DESCRIPTION OF INTELLIGENCE REQUIREMENT AND DETAILED TECHNICAL DESCRIPTION OF PROJECT (Continue on addi-
tional page if required) A device is needed which will permit photo interpreters, who
normally wear standard corrective eyeglasses, to remove them and still be able to
properly utilize stereoscopes. There is reason to believe that this can be done
by adding the proper corrective opthalmic prescription to the stereoscope eye-
pieces themselves. There is some medical opinion that indicates that this would
not only enable the PI to see better but would also serve to lessen overall eye
fatigue.
19. APPROVED BY AND DATE
OFFICE
DEPUTY DIRECTOR
DDCI
Approved For
Release 2003/01/28 : CIA-RDP78B04
70A002000060003-2
FORM
11.64 2338
n pwi
SECRET
Approved For R se 2003/ 8r-aBIA-ROP78B04770A .Q 000060003-2
Approved For RQEh~IQ~$~$'('~~RDP78B04770A0~0~?2000060003-2
23 February 1967
These development objectives describe the requirements to be met
in the design and fabrication of acuity adapters (Opthalmic corrective
devices) for the OStandard lOX eyepieces as currently used .with the
Zoom 70 Stereoscope.
A device is needed which will permit photo interpreters, who nor-
mally wear standard corrective eyeglasses, to remove them and still be
able to properly utilize microstereoscopes. It appears that this can
be done by adding the proper corrective opthalmic prescription to the
stereoscope eyepieces themselves. There is some medical opinion which
indicates that this would not only enable the PI to see better but would
also, serve to lessen overall eye fatigue.
3. REQUIREMENTS.
3.1. Configuration. The prototype holders for the corrective optics
must clip or clamp onto the standard lOX eyepiece as
used with the Zoom 70 Stereoscope, and must be easily interchangeable
from one eyepiece to another. The present color filter holder pro-
duced by s an example of a device which might be suitably mod-
ified for is particular application.
3.2. Lenses. Each set of two acuity adapters must have lenses
ground to the prescriptions to be provided by the sponsor. The
lenses shall be firmly and positively affixed to tYie holders to
avoid the possibility of accidently becoming separated from them.
The optical performance of the lenses must equal or exceed that of
a standard eye glass configurations of the same prescription. ~ ,
3.3? Index Marks. Each acuity adapter must be individually marked
L (for Left or R (for Right) as appropriate and have another mark
to indicate the top of the eyepiece. In addition each set of acuity
adapters must have matched serial numbers engraved upon them to per-
mit easy identification and to prevent inadvertent separation of sets.
C~NFI~EN~TIAL
25X1
Approved For Release 2003/01/28 :rCIA-RDP78B04770A002000060003-2
Approved For
~~~ ~-RDP78B04770A002000060003-2
3.~+. Carrying Case. Each acuity adapter set must be provided
with a fitted carrying case to provide proper protection and
storage when the adapters are not in use.
3.5. General Design. The acuity adapter should be as light
and compact as possible without being fragile.
3.6. A total of 5 sets of two adapters each shall be provided
as part of this contract.
3.7. At the time of delivery of the adapters the contractor
shall also provide 10 copies of simple Users Instructions.
3?$. A carrying case shall be provided for each set of adapters.
Approved For Release?1~~~~78B04770A002000060003-2