LOAN OF 91/2' FILM

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B04770A001600020019-4
Release Decision: 
RIPPUB
Original Classification: 
K
Document Page Count: 
12
Document Creation Date: 
December 28, 2016
Document Release Date: 
June 6, 2005
Sequence Number: 
19
Case Number: 
Publication Date: 
June 1, 1965
Content Type: 
FORM
File: 
AttachmentSize
PDF icon CIA-RDP78B04770A001600020019-4.pdf423.96 KB
Body: 
~J?:, a rye 7/ Approved'Fo lease 2005/06/23: CIA-RDP78BO47 01600020019-4 . -10 MEMORANDUM RECEIPT If .- ATTO: 1 June i 6ri DATE SUBJECT: Loan of 92" Film I hereby acknowledge receipt of the following: Seventy-five 92" X 18" frames, numbered 1924 through 1998. Length of imagery approximately 116 feet. NGA Review Complete Please return 1 signed copy(ies) of this receipt To C n Approved For Release 3 : CAAPDP F 1 D NO ED. 55 J L WHICHCMAYF BEM US36-66 !fld ST Approved Fo*l";N92?05J0?/K3 : ICIR 8B 47#01600020019-4 CONTROLS AND READOUTS The control and readout panel is the interface between the man and the machine, reflecting the na`--.re of the machine at this point. The panel depicted here--in is for an electro- mechanical machine control. Space for so1=_! state circuitry, code reader, and for a block tape reader will be allocated in the original,design to permit easy retrofit should a code reader be added in the future. When the additional soph- isticated features are added the control panel can be com- pletely removed and replaced with a control panel compatible with the electronic circuitry and the additional features. "'I. Negative Rewind '8. Number of Prints %;2. Negative Wind %;3. Search 1 3. Raw Stock Advance 3. Sta~_dby 4 Film y'y::.e 5. Exposure Setting 2. On *o. %1 7 . 14. Panc1 La 15. Ma_n,-c:ai Negative Motion 16. Strip Length COQ?~_~^l.S - *asterisk indicates readout and control Approved For Release 2005/06/23 : CIA-RDP78B04770A001600020019-4 Approved Foolease 2005/06/23 : CIA-RDP78B047 001600020019-4 READOUTS 1. Raw Stock 2. Negative '5. Auto Counter 3. Warning %;6. Number of Prints 7. Prints-in-Run CONTROLS 1. NEGATIVE REWIND Pressing thissDlenoid-held, lighted push-button will cause the negative to be rewound to the beginning frame. (Present Location Counter = 0000) and stop. Also, the light will come on and the button will be held in. he control is inoperative if in "Search" or "Pr in-.?' condi--ions, or if the "Wind" Negative but- ton is. pushed. When the beginning frame is reached, the sutton wi be released and the light will go off. The :.:achie can be stopped prior to this by pushing sae "Standby" button. 2. NEGA'- -VE Lt =_D Pressir_g His solenoid-held, lighted push-button will cause the negative to be wound upon the take-up reel. The come on and the button will be held in. The film .ee.vir~g the supply sbrage loop will cause Approved For Release 2005/06/23 : CIA-RDP78BO477OA001600020019-4 -3- Approved FoOlease 2005/06/23: CIA-RDP78BO47-001600020019-4 the machine to stop. The button will be released and the light will go off. The machine can be stop- ped at any time by pushing the standby button. The control is inoperative if in "Search" or "Print" condition, or if the "Rewind Negative" button is pushed. 3. P'LW STOCK F DVS` NCE This momentary contact, illuminated push-button will light when pressed. The raw stock will advance an amount determined by the setting of the mask each time the button is pressed. Continuous advance will be achieved by holding the button in. This control is inoperative when in the "Prrint",condition. 4. FILM SPEED 1, 2, 3, 4 This is a rotary selector switch with four settings for various film types. The function of the control is to bias the -exposure control computer in accordance wit:, speeds assigned to the positions. 5. EXPOSJlE S?:__N.: 1 2, N, 2, 4 ANA TEST f,.-.s is a rotary selector switch with six settings. 7' nor exposure setting. The function of the control is to provide a quarter, half, normal, two and four times e__-posures for the exposure control and Test Seth vs. Approved For Release 2005/06/23 : CIA-RDP78BO477OA001600020019-4 Approved Fololease 2005/06/23 : CIA-RDP78B047001600020019-4 6. MODE ^lhis?is an alternate action, lighted push-button switch for selecting machine operation in either the "Manual" or in the "Consecutive" mode. The button lights will be split so that when in the "Manual'.' setting, the lights behind the word Manual will be lit, and when in the "Consecutive" mode, the lights behind the word Consecutive will be lit. All searching operations must be performed in the manual mode; 7.. BASIS This is an alternate action lighted push-button. The button lights will be split so that when in the "Frame" position the word Frame will be lit and when in the "Footage" position, the word Footage will be lit. The switch functions as a selector for the inputs to the Present Location Counter and the Auto Counter. Wienever the switch is changed from one position to the other, the Counters will be reset to 0000. 8. NJMDE_: OF PR:N?`S This is a lighted alternate action push-button. junction is to select either an indefinite num- bar of prints when in the "Multiple" position, or the numbar of ,rints entered in the Number of Prints Counter when in the ".ounter" position. If in the Approved For Release 2005/06/23 : CIA-RDP78B04770A001600020019-4 -5- Approved For lease 2005/06/23 : CIA-RDP78BO477001600020019-4 "Multiple" position, the machine may be stopped by pushing the "Standby" button. The"Prints-In-Run" Counter is to be used for determining the total number of prints made in any run. It may be reset at any time. 9. SEARCH ,This is.a.solenoid-held push-button that lights when it is engaged. it is only operative when in the "Manual" mode. The button is released and the light goes off when the number desired (which was entered in the Auto Counter) is reached. The "Search" Button disables thie "Manual Negative Motion1B control. "Search" 'is also inoperative if the Negative Rewind or Nega- tive Wind controls are activated. 10. STANDBY This is a momentary contact push-button that lights when pressed. Its function is to stop the machine from winding, rewinding, searching, printing, or advancing raw stock, when the button is pressed. The machine will finish the exposure if in the middle of, an exposure, if s. arching, it will follow the same stopping procedure that it does when the correct frame is found. If winding or rewinding, it will permit comp etion of the function. The Standby light will light when pushed, and also when the machine is ready after a timed warm-up period when the machine is first Approved For Release 2005/06/23 : CIA-RDP78BO477OA001600020019-4 turne on. -6- Approved Foolease 2005/06/23 : CIA-RDP78BO47001600020019-4 11. PRINT This is a solenoid-held, lighted push-button that lights when it is engaged. It is inoperative if searching, rewinding, winding or advancing raw stock or before the machine is warmed up. It will also be inoperative if the number of prints counter is 00 when the number of prints switch is in the "Counter" position. Its function is to start the machine printing. In the "Manual" mode the button will be released when the Number of Prints Counter goes to zero, or when the Standby button is pushed ii in the "Multiple" condition, and the print cycle is completed. This is a momentary contact illuminated push-button that lights as long as the line contactor is engaged. When this button is depressed, current :=lows through the energizing coil of the line contactor. Auxi- _iary normally open contacts in the line contactor parallel the contacts of this switch so that the contactor remains engaged when the button is released. This is a momentary contact illuminated push-button that causes all power to the machine to be discon- 'flected when pushed. The button will be red in color A`p~o1'F~recY&W 2'bo#/66& : AibO*7Abt1 24 -7- Approved Foqolease 2005/06/23 : CIA-RDP78B047*01600020019-4 right hand corner o- the control panel. When de- pressed, the energizing coils of the A.C. line con- tactor is opened and the contactor opens. The nor- mally closed contacts in the line contactor cause the push-button to be lighted when the contactor is open and the main circuit breaker is on. 14. PANEL L. AMP TEST This is a combination push-button switch and poten- tiometer. When depressed, all panel indicators that use an incandescent bulb as a light source are illu- minated and the warning buzzer is activated. The rotary control will cause the light intensity to be continuously variable from full on to off. The push- button will light the bulbs only to the maximum in- t nsity. 15. MANTJ _LL NE A 17 VE M T ON This '"stick" control connected to a potentio- meter. Movement of the stick to the right or left causes t---e potentiometer output voltage signal to vary to control the capstan drive motor. Moving the stick to the right will cause the capstan drive to move the negative film forward, and moving the stick --o the "left will cause the capstan drive to move the negative film backwards. The system will be damped so that the direction of motion cannot .be Approved For Release 2005/06/23 : CIA-RDP78BO477OA001600020019-4 Approved Fo*Iease 2005/06/23 : CIA-RDP78B0477001600020019-4 suddenly reversed or otherwise damage the film. READOUTS 1. RAW STOCK This backlit readout will be lit when an undesir- ~f~~~ J ~:.i a a'~a~ x:11, It will light, for example, to indicate that the raw stock supply is low. 2. NEGATIVE This backlit readout will be lit when an undesirable condition exists in the Negative sub-system. 3. WARNING This is a backlit readout that will be activated only in case of machine malfunction. For minor failures, t-,-)-e illumination will be constant; for major failures, He readout will flash on and off in synch- ronizatt_on with the warning horn. Any failure in- dication would automatically stop the machine in its standby mode, but a major failure would activate the e argency off control. 4. P ES_N" LOCA T ION This is a four digit presetable electromechanical bidirectional counter mounted on the control panel for ease of access and viewing. I represents the frame- nur.ber or footage that operator wishes to start from as a datum. When the BASIS selector is in the ApRro d fde1 asg 20 U5/?6/2IDuaCLA/ -RDp 8 0 A?g16eO GW 9t4 -9- Approved Forrease 2005/06/23: CIA-RDP78B0477OP01600020019-4 (depending on direction of travel) one for each frame of Films passed. When the BASIS selector is in the F03TAGE position, this counter will add or subtract one for.each foot of film passed. When- ever the BASIS is changed, the counter will be reset to C000. 5. AUTO COUNTER. This s a four digit presetable electromechanical counter that counts down.' When in the manual mode, the operator can set the counter to the number of frames (or footage) that he wishes to advance. Pressing the "Searc:i" button causes the negative film to advance. Each frame (or foot of distance) of film -that is Sassed causes the counter to be re- duced by c e. When the counter reads 00c3, the machine will stop. if the operator wishes -to make prints of N consecutive frames, he will enter the Number N into the auto counter. The "Mode" switch must be set in the consecutive position and the number of prints counter must not equal zero. When the 'Perin t'P button is pushed the machine will pro- ceed to make prints of the N frames. When the auto counter ends 0000, the machine will stop. 6. NUMB C-1- PIN-_S his is a two-digit electromechanical presetable counter that counts down. When the associated switch Approved For, Release 2005/06/23 : CIA-RDP78B04770A001600020019-4 is in the '?Counter" position, the machine (after the -10- Approved For lease 2005/06/23 : CIA-RDP78BO477001600020019-4 "Print" button has been pushed) will make the number of prints that the operator entered into this counter. When this counter counts down to 00, the machine will stop if in the manual mode, or go on to the next frame in the consecutive mode. If in the consecutive mode, the counter will automatically revert to the number that the operator. originally entered into this counter so that this number of prints of the N frames will be made for each suc- cessive frame until the auto counter equals 0000. 7. PRINTS-IN-RUN This is a four-digit electromechanical counter that. counts up and that is resettable'hy the oper- a._ow . -hs _,..--ic t.-on_ is to count prints that have been ._w,3e cve_ viateva-r the operator wished to classify ::r. . This could be on a basis of time or of reek. Approved For Release 2005/06/23 : CIA-RDP78BO477OA001600020019-4 RAW . STOct NEGATJ VE ~L }AJlr'1D P k:z;if n vc-' WIJN J'4W S To. -k Ex osu .: . "Approved For-Release 2005/06/23-: CIA-RDP78BO477OA00160002001?9-4 - J 1~~s~NT1OcII ~/oN~ U TO COO) TE~7 MODE" C jltpY.tft,~ Ah S != oo7-6 -Id NU/`413 R 00R PR INTS CoiJ1Y=~C Approved For Release 2005/06/23 -: CIA-RDP78B04770A0.01600020019-4 WN ING OFF F TI I TS - IJ'& UN lit P 7i'!71- psi ry Go,\1TRo~.