LINEAR PHASOLVER MEASURING ENGINE

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B04770A001500070007-3
Release Decision: 
RIPPUB
Original Classification: 
K
Document Page Count: 
4
Document Creation Date: 
December 28, 2016
Document Release Date: 
June 28, 2005
Sequence Number: 
7
Case Number: 
Publication Date: 
April 30, 1965
Content Type: 
REPORT
File: 
AttachmentSize
PDF icon CIA-RDP78B04770A001500070007-3.pdf308.36 KB
Body: 
STAT STAT Approved For Release 2005/07/13 : CIA-RDP781304770A001500070007-3 April 30, 1965 PkOV 40 WINE phasolver is an adaptation of the vtarv phasolver. hasolver is a standard product of thel I STAT which measures shaft angles to a very high ad,- racy, It is used for remote measuring of radar antenn3 ition, theodolite pointing direction and the phasolver uses the same principles as true phaeolveibut for measuring linear dimensions to sab. accuracy. STAT About two years ago, foresaw the need for 3 new measuring engine, but he did not have a new machine to tie it to. The shortcomings of the then existing yardsticks were painfully apparent to him. The electronics were poorly done with low reliability and uncertain drift. Some of them were limited by the lead screw which had about reached the end of its advancement in capability and was slow. Othera were limited by pulse detection and counting rate. In looking around for a solvtion the best bet appeared to be the phasolver. It offered the following advantages: STAT (a) Determination of position was unique and us ambiguous and did gat depend on counting pulses. (b) It did not use a lead screw and the traversing *peed was thus sat limited by the measuring speed. (c) The electronics were well developed and had many years of production and development debugging behind them. The c4,1y phasolver electronics were extraordinarily stable and free of drift. Since linear measuring has acme problems different than angular measuring I I decided to get them started with a feasibtitty study. It is a good thing he did, too. NGA Review Complete Approved For Release 2005/07/13 : CIA-RDP78604770A001500070007-3 Approved For Release 2005/07/13 : CIA-RDP78604770A001500070007-3 ,1111111, r Phasolver Measuring Engine 30, 1965 4- olver works on the basis of determining the capawltive between metallic patterns on two glass plates, e d a coupler, which slide along each other. The plate would be mounted on the stationary bed of tile engine. The coupler pattern is merely straight perpendicular to the direction of motion. The driver would be mounted to the moving head of the meaburing engine and its pattern has a sinusoidal variation as show on the attached Sketch. TWo pattern designs were to be tested in the feasibility demonstration. The electronics measures the phase angle between ele trica signals impressed on the driver and picked up by the coupler. The phase angle varies with position, hence, the term "phasolver." The entire problem 110: been the preparation o:i7 a pattern by( STAT d as much trouble with the linear patterns STAT d making the original rotary patterns. The project was stalled for about 10 months waiting for good patterns. The electronics were completed almost a year al-Jo. STAT Alter Ifinally made a good driver master pattern of photographic emulsion on glass, made working pattern: STAT from thai Imaster of deposited metal on glass. also made the coupler. The test program is now under way to determine how good the phaeolver really is. Test results are encouraging but, of oourse? not complete and iefinitive. The electronics aro very stable and free of drift. When a measurement is set up in the evening and left overnight, it is still registeriiv the same measurement to 1/10 micron the next morning. (Rome temperature is controlled to + 10F and relative humidity varies less than + 3%.) The pattern appears to have a scale error of about 15 microns over its 20 inch length. A scale error was expected and .1 can be balanced out electrically. Also there appears to be a variation from pole pair to pole pair of from 1/4 micron to about 1.1/3 micron. They are not sure whether Ails occurs in the test equipment or in the phasolver, but they suspect the test equipment. They are presently trying to pin down the source of the error. Probably the most Approved For Release 2005/07/13 : CIA-RDP78604770A001500070007-3 STAT STAT STAT