R & D CATALOG FORM DATE 15 April 1969 1. PROJECT TITLE/CODE NAME 2. SHORT PROJECT DESCRIPTION Microdensitometer Modifica- This project is to develop a digital scan controller tions (Scan Control and and a time based. sampling system for the 0 1032T 2 Sampling System) Trichromatic Microdensitometer now in use at NPIC 3. CONTRACTOR NAME 4. LOCATION OF CONTRACTOR Declass Review by N 5. CLASS OF CONTRACTOR 6. TYPE OF CONTRACT Manufacturer FP 7. FUNDS B. REQUISITION NO. 9. BUDGET PROJECT NO. FY 19 68 $ None FY 19 69 $ 10. EFFECTIVE CONTRACT DATE (Begin - end) 11. SECURITY CLASS. AA - Confidential T - Unclassified FY 19 70 $ None may 1969 - July 1969 W - Unclassified _ 12. RESPONSIBLE DIRECTORATE/OFFICE/PROJECT OFFICER TELEPHONE EXTENSION DDI/NPIC/TSSG/DED 13. REQUIREMENT/AUTHORITY The 1032T Microdensitometer is limited in its ability to (a) scan microscopic areas of imagery without producing extraneous data and (b) analyze film imagery which exceeds 170 lines per millimeter in resolution. 14. TYPE OF WORK TO BE DONE Engineering Development 15. CATEGORIES OF EFFORT MAJOR CATEGORY SUB-CATEGORIES Microdensitometry Precision Measurement Optical Systems 16. END ITEM OR SERVICES FROM THIS CONTRACT/IMPROVEMENT OVER CURRENT SYSTEM, EQUIPMENT. ETC. The Contractor will modify the Microdensitometer to: (a) Control the length of the scan with digital switches and counters instead of microswitches, and. (b) change the density sampling system from a mechanical base to a time base which will allow a sampling rate of 10 samples per micrometer (versus the present rate of 1 sample per 17. SUPPORTING OR RELATED CONTRACTS (Agency & Other)/COORDINATION micrometer). This contract will be run concurrently with a contract to modify a stage for the 1032T Microdensitometer. There is no overlap on these projects. Coordination has been performed through EXRAND. 18. DESCRIPTION OF INTELLIGENCE REQUIREMENT AND DETAILED TECHNICAL DESCRIPTION OF PROJECT (Continue on addi- tional page if required) The scan controller consisting of decade counters, switches and comparison logic will replace the microswitch controls to allow the scan length to be preset to from 1 micrometer to 1 decimeter. This precise programming of the scan length will eliminate the extraneous data now produced on small scans and will reduce costly processing of the data. The sampling system will be modified so that it will be triggered by a crystal oscillator (the "clock") instead of directly by the stage movement. The oscillator will allow better control of the sampling rate and will permit more frequent sampling, thereby reducing the limitations to analyzi 19. APPROVED BY AND DATE ig resolution imagery." OFFICE DEPUTY DIRECTOR DDCI Approved Fo Release 2005/05/20 : CIA-RDP78B0 770A001400070015-5 5X1 g SECRET Approved For Release 2005 120F2C A-RQP78B04770A001400070015-5 FORM ,w 1 1. 14 2338 SECRET