REQUEST FOR APPROVAL OF ACUITY ADAPTERS FOR (SANITIZED) EYEPIECES PROJECT WITH (SANITIZED)FROM FY-1967 FUNDING

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B04770A000700030009-4
Release Decision: 
RIPPUB
Original Classification: 
S
Document Page Count: 
6
Document Creation Date: 
December 28, 2016
Document Release Date: 
November 8, 2006
Sequence Number: 
9
Case Number: 
Publication Date: 
March 1, 1967
Content Type: 
MF
File: 
AttachmentSize
PDF icon CIA-RDP78B04770A000700030009-4.pdf322.72 KB
Body: 
Approved For Release 2006/114OrE FIDP78B04770A000700030009- 25X1 25X1 ft O/D l mmoraudAm of 4 fa4 . u&D A ti ti 2. .Y'is attached staff t y , .izzeut ir'Po ti a u4 .ciao for t Attar .ts z &/r d atiou. Ph togmphia Interpretation Certer Di stri"auti Orig i F1C/ /r d (After Approval i CI..,3S/NPIC I .... Ch t / /I4PIC 1- LE 1 of Approved For Release 2006/11/09: CIA-RDP78BO477OA000700030009-4 ' Approved For el eN?1DlE1NT1AtRDP78BO477OAOOO7OOO3OOO94 -"IV W 23 February 1967 EYEPIECES - STAFF STUDY 02127 25x1 0 To develop a device which will permit a photo interpreter to set his own opthalmic correction on a stereoscope eyepiece, thereby opti- cally optimizing the microscope for his personal use and making it un- necessary for him to wear glasses while looking through the instrument. In Au st of 1964 the Imagery Analysis Staff received a recommenda- tion from of the Optics Panel Scientific Advisory 25x1 Board, that an opthalmic correction device be developed and tested for use by photo interpreters. He believes that, interpreters using this device would not only see better but would experience considerably less eye fatigue than if they were to wear their own glasses as they now do. Following this recommendation CIA/IAS requested that the Technical De- velopment Staff inves ' a the ossibility of providing the type of adapters suggested byl 25x1 3. DISCUSSION: a. Current Procedures.' Photo interpreters who require opthalmic corrective devices must wear eyeglasses when using a microstereoscope. b. Origin of Concept. This concept of individual adjustable eye- pieces containing nally suggested by nat4almic corrective prescriptions, origi- in his capacity as a member of the Optics Panel Scientific Advisory Board, is based on theoretical and empirical findings that eyestrain and fatigue are materially lessened when opti- mum optical aids are employed by individuals doing visually exacting tasks such as those involved in the photointerpretation process. t c. Proposed Program. The proposed program will provide five sep- arate matched sets of acuity adapters, each uniquely designed for an individual within the photo interpretation group. The initial five photointerpreters were selected to provide a test sample and will rep- resent a cross section of the visual anomalies found among a represent- CONFIDENTIAL Approved For Release 2006/11/09: CIA-RDP78B04770A00070'0030009-4 Approved For Release 2006/11/09: CIA-RDP78B04770A000700030009-4 DD t=1DENIIAL ative group of individuals, e.g. astigmatism and myopia. These five sets are to be tested operationally to prove the feasibility of the concept. d. Selection of the contractor. This contract is to be awarded on a sole source basi too small to solicit on a broad participation basis. has been se on the premise that the acuity adapters are to 'Be designed for dewing instru- ment and on the acknowledged technical competence of the firm itself. Should the initial five sets serve to prove hypothesis, competitive bids will be solicited to procure a larger quantity. e. Contract Period. The acuity adapters are estimated to be de- liverable within two or three months from initiation of the contract. f. Coordination. Internal and external coordination has been part of the project since its inception. The appropriate technical personnel of PAG, CIA/IAS and TID have been briefed on this project. This project has been coordinated with DDS&T/ORD and presented to the Committee on Photographic Exploitation and representatives of Army, Navy and Air Force. g. Alternative. There are two obvious alternatives to the de- velopment of acuity adapters: 1. Use of contact lenses. 2. Continuation of present procedures. The use of contact lenses poses a problem of inducing the photo interpreter to accept them. Indications are that many photo in- terpreters would probably not accept the use of contact lenses as readily as acuity adapters, and they cannot legally be forced to use them. The expense of contact lenses would probably be about equal to acuity adapters. As_explained above, the second alterna- tive is unacceptable. It is recommended that approval to contract with f F7_6.7 fu d f - -I.,--__ o n s or mont Tab A. Catalog Form Tab B. Develo went Ob ectives Attachment: Proposal 25X1 25X1 25X1 25X1 Approved For Release 211t0R8B04770A00070A030009-4 .9 R & D CATALOG FORM DA 10 February 1967 I. PROJECT TITLE/CODE NAME 2. SHORT PROJECT DESCRIPTION The fabrication of acuity adapters for microscope eyepieces so that each 25x1 Acuity Adapters for= interpreter may have his own, unique, opthalmic Eyepieces correction. 3. CONTRACTOR NAME 4. LOCATION OF CONTRACTOR 25X1 5. CLASS OF CONTRACTOR 6. TYPE OF CONTRACT Manufacturer Fixed Price 7. FUNDS S. REQUISITION NO. 9. BUDGET PROJECT NO. FY 19 $ None NP-V-12-02127 FY 19 10. EFFECTIVE CONTRACT DATE (Begin - end) 11. SECURITY CLASS. 25X1 M h M 1 6 AA-Confidential arc ay - 9 7 FY 19 $ None T-Unclassified W-Unclassified 12. RESPONSIBLE DIRECTORATE/QFFICE/PROJECT OFFICER TELEPHONE EXTENSION DDI/NPIC/TDSI 25x1 13. REQUIREMENT/AUTHORITY Both medical and psychophysical experts have deemed this method superior to glasses and contact lenses for refractive correction during photo interpretation. 14. TYPE OF WORK TO BE DONE Engineering Development 15. CATEGORIES OF EFFORT MAJOR CATEGORY SUB CATEGORIES Viewing Systems Lenses Microscopes 16. END ITEM OR SERVICES FROM THIS CONTRACT/IMPROVEMENT OVER CURRENT SYSTEM. EQUIPMENT. ETC. Five separate prototype adapter sets, cases and instructions. 17. SUPPORTING OR RELATED CONTRACTS (Agency & Other)/COORDINATION There is no known equipment available or under development which will satisfy this requirement. This pro- ject has been coordinated with: DDS&T/ORD, and presented to the committee on Photographic Exploitation and representatives of the Army, Navy and Air Force. 18. DESCRIPTION OF INTELLIGENCE REQUIREMENT AND DETAILED TECHNICAL DESCRIPTION OF PROJECT (Continue on addl. tional page if required) A device is needed which will permit photo interpreters, who normally wear standard corrective eyeglasses, to remove them and still be able to properly utilize stereoscopes. There is reason to believe that this can be done by adding the proper corrective opthalmic prescription to the stereoscope eye- pieces themselves. There is some medical opinion that indicates that this would not only enable the PI to see better but would also serve to lessen overall eye fatigue. 19. APPROVED BY AND DATE OFFICE DEPUTY DIRECTOR DDCI FORM 2338A pproved For Release 2006i1110$EUJkTRDP~~OA000700030009-4 Approved For Release 2006/111095:ECR1RDP78B04770A000700030009-4 -/ (When Filled In) Approved For Release 2006/11/09: CIA-RDP78BO477OA000700030009-4 "W CONFIDENTIAL 23 February 1967 ACUITY ADAPTERS FO lOX EYEPIECES These development objectives describe the requirements to be met in the design and fabrication of acuity adapters (Opthalmic corrective devices) for the Standard lOX eyepieces as currently used with the Zoom 70 Stereoscope. A device is needed which will permit photo interpreters, who nor- mally wear standard corrective eyeglasses, to remove them and still be able to properly utilize microstereoscopes. It appears that this can be done by adding the proper corrective opthalmic prescription to the stereoscope eyepieces themselves. There is some medical opinion which indicates that this would not only enable the PI to see better but would also serve to lessen overall eye fatigue. 3.1. Configuration. The prototype holders for the corrective optics must clip or clamp onto the standard lOX eyepiece as 25x1 used with the Zoom 70 Stereoscope, and must be easily interchangeable from one e e iece to another. The present color filter holder pro- duced by s an example of a device which might be suitably mod- 25x1 ified for is particular application. 3.2. Lenses. Each set of two acuity adapters must have lenses ground to the prescriptions to be provided by the sponsor. The lenses shall be firmly and positively affixed to the holders to avoid the possibility of accidently becoming separated from them. The optical performance of the lenses must equal or exceed that of a standard eye glass configurations of the same prescription. 3.3. Index Marks. Each acuity adapter must be individually marked L (for Left) or -R (for Right) as appropriate and have another mark to indicate the top of the eyepiece. In addition each set of acuity adapters must have matched serial numbers engraved upon them to per- mit easy identification and to prevent inadvertent separation of sets. CONFIDENTIAL Approved For Release 2006/11/09: CIA-RDP78BO477OA000700030009-4 Approved For Release 2006/114Q9 A-RDP78B04770A000700030009-4 1 1ONFEPL I 3.14. Carrying Case. Each acuity adapter set must be provided with a fitted carrying case to provide proper protection and storage when the adapters are not in use. 3.5. General Design. The acuity adapter should be as light and compact as possible without being fragile. 3.6. A total of 5 sets of two adapters each shall be provided as part of this contract. 3.7. At the time of delivery of the adapters the contractor shall also provide 10 copies of simple Users Instructions. 3.8. A carrying case shall be provided for each set of adapters. CONFIDENTIAL Approved For Release 2006/11/09: CIA-RDP78B04770A000700030009-4