DEAR ROBIN:

Document Type: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP78B04747A001700010004-9
Release Decision: 
RIPPUB
Original Classification: 
K
Document Page Count: 
5
Document Creation Date: 
December 28, 2016
Document Release Date: 
April 23, 2001
Sequence Number: 
4
Case Number: 
Publication Date: 
February 12, 1965
Content Type: 
LETTER
File: 
AttachmentSize
PDF icon CIA-RDP78B04747A001700010004-9.pdf173.37 KB
Body: 
Approved For Release 2001/05/11 : CIA-RDP78B04747A0017R1 -?evlew by NIMA/DOD STATOTHR 12 February 1965 I have looked into changing the anti-reflection coating to a standard coating with higher reflectance values and tilting the front glass. The coating manufacturer informed me that the standard magnesium fluoride coating will reflect about 3% instead of the 2/ for the special HEA coating of the optical Coating Laboratory. The representative from OCLI agreed that the standard coating will show less surface smudges than the HEA coating, This coating is being procured along with tilting the glass 7, The 7? tilt is based on what is practical with the present design, test results, and calculations. A short test was conducted by placing a 10x10 glass plate (uncoated) in front of a collimator. An observer was positioned in front of the plate at the same distance he would occupy in front of the viewer. With the glass untilted a person could not see himself in the glass plate while looking into the collimator at a target. Even glasses would not cause enough reflection to show up. A virtual image was possible by holding a mirror over one eye and reflecting the light back to the glass. By tilting the glass 7?, this image was moved to the upper edge of the 10xlO plate. The tilted glass also helps to eliminate reflection from 8ver- head lights behind the operator. With the glass tilted 7 the light could be as low as six feet and 12 feet behind the opera- tor and still not be seen. has been given the formal okay to start work on Phase II, part 2. The completion date for this is 7 May 1965. I have also spent some time determining new specifications for them. The overlapping method complicates the specification when the gratings are tested as individual items without overlap. Would Dick look the enclosed specifications over and return them with any comments he may have. The attached sheet provides basic data on the subject. The vacuum hose and pump sound fine. We will have a connector- on the viewer with a serrated connection to accept your hose. When you return the specifications could you include the I.D. of the hose you will use. I will be looking forward to seeing you around the first of May for the acceptance test, assuming you can send us a grating the latter part of April. Enclosures (2) STATOTH Approved For Release 2001/05/11: CIA-RDP78B04 Sincerely, Approved For Release 2001/05/11 : CIA-RDP78BO4747AO01700010004-9 3.0 REQUIREMENTS (addendum) 3.1 The technical design goals of the 10x10 transmission grating replicas which are to be produced during the second try of Phase II shall be as follows: 3.1.1 Wavelength band to be used - 5086A. Test grating at 5000 - 5500A. For intensity data intergrate results from 5000 - 5500A?. Angular deviation measurements shall be measured at 5086A?. 3.1.2 The grating shall disperse a total of 27 orders consisting of the central order and 13 orders on each side of center to the required amounts as stated in Section 3.1.3. Any additional orders are acceptable, but they should not detract from the transmission values required. 3.1.3 The nominal angular deviation of the central ray in each exit pupil of the various orders shall be: First order: 25' Second order: 49' Third order: 1? 13' Fourth order: 1? 38' Fifth order: 2? 2' Sixth order: 2? 27' Seventh order: 20 51' Eighth order: 3 0 15' Ninth order: 3? 40' Tenth order: 4? 4' Eleventh order: 4? 29' Twelfth order: 4 0 53' Thirteenth order: 5? 18' The tolerance for each of the above deviations shall be +3 minutes. Approved For Release 2001/05/11 : CIA-RDP78BO4747AO01700010004-9 Approved For Release 2001/05/11 : CIA-RDP78BO4747AO01700010004-9 3.1.4 Intensity Variation When two crossed replicas are used, the light intensity variation over the exit pupil matrix field shall be no greater than 4:1. Due to the overlapping of the exit pupil orders the light intensity variation between discrete orders need not be the 4:1 ratio of the combined system. Due to the overlapping in both X and Y planes a complex arrangement exists. When individual readings are made of the transmission in each order, the following formula converts any set of individual readings to the value obtained when the gratings are crossed and exit pupils are used at 50% overlap. T _ 2 (Ta x Tb) + (Ta) 2 + (Tb) 2 ab where Tab is the transmission of 4 combined orders. Such Order: Xaxis# Yaxis# Combinations: 4 4 5 4 4 5 5 5 then T = 4 a Tb = 5 3.1.5 Number of order combinations. With a +13 order system there are 676 order combinations. 3.1.6 The minimum transmission in any of these 676 order combinations shall exceed .0225%. This corresponds to the 3% for a single order in the previous specification. Approved For Release 2001/05/11 : CIA-RDP78BO4747AO01700010004-9 ApproMe For Re lease MJ'L/QP/11 : CIA-RDP78BO4747AO01700010004-9 BY.----------- - - _ -------- _ ------------------------ SHEET NO- 0 a 4 6 Q 10 12 OF 7So' OWER LAP /4PPR,A CN I 3 5 7 9 to 13 6 1 a 3 4 5 G .=-X/,r pupils EACH PUPAL . a g g x, a 9 9 /itKHFS ..4-r 3.6 9,) h .- Tor L tX/7 PUPIL 11V107-11 UAI r, SR CQA/rr oL OF 5PEc1 FiCArlUN X) -) Y Ii C`f/T av,~~L ? 1'1(2P4 ova GAS AREA /43 x'. /4Z 'N. 1?E44t'pw iH if OF --Cow 9.uvE,0 IF x!1 PUPILS STATOTHR FOUR. Fx,r P/PIL Duce L,4";, tc Fog-m /N!?~ CUM QI'y; D ST/aAIDAR0 METHoQ X1i -Y Y I) 1 -mot- 11111 1 1 ~Q _ 1 -++r;- X1)Yg K0 Y O, TYi'DlC/4L E xi r OVERLAP Approved For Release 2001/05/11 : CAA=RDP'?8B04747AO01700010004-9 Approved For Release 2001/05/11 : CIA-RDP78BO4747AO01700010004-9 MEMORANDUM FOR: Robin I have honestly tried to understand Ray's formula for T and to determine what it really means. I have had absolutely no success, either in deriving the formula or interpreting it. If I have this much troutle, maybe he'd better be a bit more explicit in defining his terms, and what he means. Or perhaps this is an indication of how far my 3aathematical skills have slipped. In item 311, I believe the trial grating is still 2 x 2 ih size - he may be looking ahead. STATOTHR 16 Feb 1965 DATE) FORM MAYF BEM US10-101 AUGH 54 IQI WHICH REPLACES ED. Approved For Release 2001/05/11 : CIA-RDP78BO4747AO01700010004-9