MAINTENANCE MONTHLY UR REPORT - JUNE 1966

Document Type: 
Collection: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP68B00724R000200310010-5
Release Decision: 
RIFPUB
Original Classification: 
S
Document Page Count: 
1
Document Creation Date: 
December 12, 2016
Document Release Date: 
April 5, 2002
Sequence Number: 
10
Case Number: 
Publication Date: 
June 1, 1966
Content Type: 
PERRPT
File: 
AttachmentSize
PDF icon CIA-RDP68B00724R000200310010-5.pdf82.45 KB
Body: 
''[[ IDEA-3232-66 ApproS Gor Release 2002/06/13S~1~DP688A~,724R00020031001ffy 4 011 4 SUBJECT General : Materiel S ecific: Maintenance Monthly UR Report - June 1966 X1XKXXX4) t# REFEREncES ro j eC i recti ve # ='g" 6-1. Hydro pump, Part Number - 66YC300, Serial Number - 48. Hydro pump leaks at seal drain. Article 359. Total time on item - 79.3 hours. Reason for failure - Unknown. Negative. 6-2. Transponder, C-618T-3, Serial Number - 2734. UHP went out after take-off. Article 359. Total time on item - Unknown. Reason for failure.- Unknown. Negative. 6-3. Dynamotor, Part Number - DY107, Serial Number -Unknown. UHF Guard inoperative on T/R and G. channel 1 very weak, Article 381. Total time on item - Unknown. Reason for failure - Unknown. Negative. 6-4. Wing flap selector valve, Part Number - SP-13680-1, Serial Number - 153048. Engine rolled back to replace flap selector valve (discrepancy found on maintenance check). Article 381. Total time on item - Unknown. Reason for failure - Unknown. Negative. 6-5. Driftsight, Part Number - PE500-0156, Serial Number - 238. Power changer noisy both directions. Article 381. Total time on item - Unknown. Reason for failure - Unknown. Negative. 6-6. Power changer motor, Part Number -'PE152-1627, Serial Number None. Power changer has noise. Article 348. Total time on item - Unknown. Reason for failure - Unknown. Negative. 6-7. Defroster fan, Part Number - SP-M6001B-1A, Serial Number - 98.' Defroster fan inoperative. Article 348. Total time on item - Unknown, Reason for failure - Unknown Negative. 6-8. EGT Indicator, Part Number - SP-BH185R-11D, Serial Number 371. Warning light on EGT indicator appears to be intermittent. Article 381. Total time on item - -Unknown, Reason for failure - Unknown. Negative. 6-9. Altimeter, Part Number - SP-Q409-1, Serial Number - 56-16318. Altimeter sticks, lags approximately 250 feet at altitude. Article 349. Total time on item - Unknown. Reason for failure - Unknown.. Negative. -6-10. Altimeter, Part Number - SP-Q409-1, Serial Number - 56-16995. Altimeter sticks. Article 348. Total time on item - Unknown. Reason for failure -Unknown. Negative. 6-11. Artifical Horizon Instrument, Part Number - SP-Q468-1, Serial Number - AF52- 40464. Artificial horizon off flag on all the time.- Article 349: Total-tIme-on -item Unknown. Reason for failure - Unknown. Negative. 6-12. D.C. Generator,. Part Number - SP-30826-21A, Serial Number - R61. D.C. Generator appears to have a shorted field - erratic voltage output. Article 349. Total time on item - 15.6 hours. Reason for failure - Unknown. Negative. 6-13. Servo Control relay, Part Number 613506-1. Serial Number - Unknown. Auto pilot would not engage when turned on. Article 349. Total time on item - Unknown. Reason for failure - Unknown. Negative. 6-14. IFF, Part Number 81413, Serial Number - 597. IFF inoperative. Article 349. Total time on item - Unknown. Reason for failure - Unknown. Negative. 6-15. Trans Po 'rov l"1roMU le0se It1S'W3113S&laeR 80226 P.20(Wp'65eiver removed, HF radio inoperative. Article 349. Total time on item - Unknown. Reason for fa i Mare - Unknown. Negative. grPRFT