MEMORANDUM FOR THE RECORD
SUBJECT : Trip Report - Meeting on Personal and Life Support Equipment
On September 26, 1963, a meeting was held to review the 25X1
status of personal and life support equipment for project OXCART.
Attendees included:
25X1
. Headquarters:' Col. Ledford
Mr. Parangosky
25X1
25X1
LAC
- Firewel Co.
- David Clark Co.
Civil Servants Mr. Shepardson -.Wright-Patterson AFB
Mr. Redding - Wright-Patterson AFB
Problems, discussion, and action to be taken are as follows:
Problem: Oxygen consumption vs. ships supply.
Discussion and action: It was agreed that 25 liters per minute
be accepted as a base line from which to compute duration vs. supply.
Cockpit pressurization at 26,000 ft,, will remain the same. A failure
of one system at mission mid-point is possible and sufficient oxygen
must be available for safe return on the remaining system.
By the end of November of this year the larger oxygen bottles,
1100 cu. in. vs. the present 875 Cu. in., will be installed. These
bottles will be charged to.2800 PSI vs. the present 2000 PSI.
NRO review(s) completed.
Approved For Release 2004/0521 CIA-RDP67B -
25X1
Approved lWelease 20
When the larger bottles, charged to the higher pressure, are
installed a mission of eight hours and fifteen minutes is possible
with failure of one system at mission mid-point. This assumes a
consumption rate of 25 liters per minute.
The possibility of charging the bottles to 3000 PSI will be
pursued by Firewel Co.
Problem: Readability of ships oxygen pressure gauge.
Action: A top priority item for Firewel Co. to provide a gauge
that can be read quickly and accurately. LAC may have to relocate the
gauge to eliminate paralax error.
Problem: Oxygen Equalizer Valve
Discussion: This device is required to insure that both ships
oxygen systems bleed down together. To date, Firewel Co. has not
been able to produce an acceptable valve.
Action:- Firewel will continue working on the problem and LAC
will try their own approach.
Problem: Visor Reflectance with full pressure suit helmet.
Action: D. Clark recently received a new laminated visor which
25X1 will be evaluated ASAP. ll pursue his idea of a
louvered piece of metal 'wRIch will block out the sun and still permit
necessary vision.
Problem: Neck Seal vs. Face Seal in full pressure suit helmet.
Discussion: Two LAC pilots and two of our pilots have suits
with the neck seal. Flights will continue with these garments to
gather additional information regarding oxygen consumption and comfort.
Problem: In-flight Feeding
25X1
25X1
Action: I I will contact Hamilton-Standard to
investigate the device being used in project APOLLO. D. Clark Co.
has a device in process.
Problem: Urinal for full-pressure suit.
Action will work with Mr. Shepardson at Wright-
Patterson for u on.
Approved For Release: 2004/05/21 : CIA-RDP67BOO511 R000100110029-8
Approved Goelease 200
Problem: Ejection Seat D Ring
Discussion: A new D ring configuration was mocked up and checked
with subject pressurized. The subject was able to reach the D ring
under pressure, however, the back up system D ring was barely reachable.
9
Action: LAC will improve back up system D ring.
Problem: Metal palm bar in pressure suit glove.
Discussion: Two pilots would like to have the bar re
d
move
or
modified. The bar should not be removed because of the resultant
bulging in case of cockpit depressurization.
Action: D. Clark Co. will modify the bar for the two pilots
desiring it.
Problem: Inadvertent actuation of flotation gear..
Action: A flap will be provided by area technics
25X1
was as an n device~nterim
fix. D. Clark 'will work on modification of the actuatio
Problem: Location of visor heat control.
Action: Although this control has been moved forward four inches,
the subject could not reach it when the suit was pressurized. LAC will
attempt to make the control more accessible.
Problem: Vent flow back pressure in full pressure suit.
Action: Firewel will investigate change of flow at different
detent positions on the flow controller. They will also investigate
the bigger problem of why so much volume is required for adequate
cooling. This problem has not been encountered in chamber runs.
Problem: Manual press to test.
Action: Item has met with pilot approval however, a more coarse
control is desired - Firewel will provide.
Problem: Retention of oxygen hoses after ejection.
Action: will locate for each pilot an exit
port for these hoses in their regular flying suit and full pressure'
suit outer garment.
Problem: Vent hose disconnecting.
Action: Firewel procuring hoses that are two inches longer.
Approved For Release 2004/05121: CIA-RDP67BOO511 R000100110029-8
Approved~elease 2004/0
RDP67130 R000100110029-8
25X1
Page
VZProblem: Helmet visor heat electrical connections.
Action: D. Clark improving connections.
Problem: Sticking of helmet visor at time of release.
Action: If the visor knob is not held down. until the visor is
pushed all the way up the seal will inflate and cause sticking. Pilots
will be reminded of this. If problem exists when using proper procedure
Headquarters should be notified.
Pressure suit glove seams.
Action: D. Clark Co. to relocate seams to provide better tactual
discrimination.
Problem: Leg stretch
Action: LAC will provide new rudder configuration that will allow,
full leg stretch when desired.
Problem: Floating position of pilot in full pressure suit.
Discussion and Action: In a pool demonstration the subject was
able to float in face down position. However, the parachute harness
did not include the emergency oxygen pan or the automatic timer pan.
Firewel to provide harness with these features plus a survival kit
for future tests. Previous jump tests indicated proper floating
position.
Problem: One man life raft.
Action: A new raft procured by Gen. Flickinger from NASA was
demonstrated which proved to be more stable than the standard Air Force
raft. More tests will be run at the area.
Problem: Pressure Suit Helmet Weight.
Action: D. Clark Co. is making every effort to reduce this weight.
An example is the replacing of the outer sun shade with a more light-
weight internal shade. New ear cups are also being provided.
Problem: Tie down cable
Action: New locking bars being provided by D. Clark.
Approved For Release 2004/05/21 : CIA-RDP67B00511 R000100110029-8
Approved lease 06410,5' CIA-RDP67B010000100110029-8
Problem: Lap belt failure.
Discussion: A lap belt failure in an ejection seat test at
El Centro prevented dummy and seat separation. LAC investigated the
problem and found that the force required to shear the pin varied
from 450 PSI to 850 PSI. This was caused by pin heat treat which
ranged from 55,000 PSI UTS to 110,000 PSI UTS.
Action: LAC is replacing the presently installed shear pin with
one which has a controlled heat treat of 55,000 PSI UTS to 66,000 PSI
UTS maximum.
Problem: Oxygen pressure warning light.
Discussion: Pilots desire an oxygen pressure warning light to
indicate low breathing pressure, or possibly both low and high oxygen
pressure.
Action: LAC will investigate.
Problem: Release of emergency oxygen hose connection at suit
controller.
Action: Firewel recently modified this connection which is being
evaluated by the pilots.
A letter will be initiated by D/TECH/OSA to each of the contractors
reconfirming their responsibilities as a result of this meeting.
(Special Activities)
Distribution:
Cy 1 - DD/8&T
2-AD4GA
3 - Dr/vs
4 - YA/o
5 - OD/ate
6-m/
7P8/c
8 ? Ss/QUA;
9. - ASD/cam
10 - ASDJ0SA (r no)
11. - BB/08A
sse (,(~~.~~- o - AS
X c- - SA~p66ved far Release 2004/65/21: CIA-RDP67B00511 R000100110029-8
~ ,J? U-"cK ~C~-aZ 1~1Jc .YD ';~e2)Z)i.06-
(W-0
25X1
25X1