PROGRESS REPORT ON (Sanitized)FOR WEEK OF 23 AUGUST.

Document Type: 
Collection: 
Document Number (FOIA) /ESDN (CREST): 
CIA-RDP67B00511R000100100005-5
Release Decision: 
RIPPUB
Original Classification: 
S
Document Page Count: 
1
Document Creation Date: 
November 17, 2016
Document Release Date: 
June 20, 2000
Sequence Number: 
5
Case Number: 
Publication Date: 
August 1, 1962
Content Type: 
MF
File: 
AttachmentSize
PDF icon CIA-RDP67B00511R000100100005-5.pdf66.26 KB
Body: 
Approved For Release0/08/O j P67B0051 I R0001 0005-5 1 August 1962 25X1A 25X1A 25X1A MEMORANDUM FOR: DC/Development Branch/DPD COPY /OF .7 o,reL 3 77/ SUBJECT : Progress Report on - for Week of 23 August. 1. a followin information is based on a phone conversation with f Itek Corporation, Lexington, Mass. 2. Little work was done on the correlator during the last week, because a complete set of the new cylinders has not been received yet. Some flight test data film was run through the correlator, but little was gained from it. One cylinder lens has been received from Perkin- Elmer and the second one is expected in about 3 weeks. is not expected to deliver any cylinders for at least 4 weeks. should produce somewhat better cylinders than Perkin-Elmer, according to Bill Davis, because is using test glasses, while P. E. is not. 3. Work on the recorder concentrated on the lens system recorder. This was being tested and run using a bench power supply, since no flyable power supplies are operational at the moment. Test are being made using a 1 mil spot size CRT and both Plus-X pan and Tri-X films. Limiting resolution in both cases seems to be about 500-600 lines/inch. (it varies over the field), which compares with a maximum of 450 lines/ inch for the fiber optics. The acuity of the lens system, particularly when using Plus-X, is also superior to that of the fiber optics. Streakiness on the film is much reduced. Exposure on Plus-X is adequate when lens is set at f/4.0. Since maximum setting of lens is f/2.0 (both these are the marked f/nos., not the operating f/nos.), there is adequate exposure margin of safety. 4. Literature received concerning the Ferranti tube indicates that it is worth looking into for second generation equipment, because of the resolution (.4 mil spot size and shape of tube. The tube has a rectangular output ncT, -tii3 a lam' x 5" phosphor area. If the rest of the tube conforms to this shape, it should permit more compact mounting. Both Itek and are looking further into this. Chief TSD/Applied Physics Branch Distribution: Orig. & 1 - Addressee Approved For Release 2000/08/03 67130 +1 1,191 005-5